相关论文: Allpix-Squared Simulations of Multi-element German…
We propose the use of germanium-on-silicon technology for indirect time-of-flight based three-dimensional sensing, and demonstrate a novel lock-in pixel featuring high quantum efficiency and large frequency bandwidth. Compared to silicon…
We present the recent development of a lightweight detector capable of accurate spatial, timing, and amplitude resolution of charged particles. The technology is based on double-sided double-metal p+\,--\,n\,--\,n+ micro-strip silicon…
Scaling properties of gamma-spectra recorded by semiconductor detectors are investigated. For practical purposes the method of simulation multicomponent spectra using single experimental spectrum are suggested.
Following work done in the energy region above 100 keV, the high-precision calibration of a co-axial high-purity germanium detector has been continued in the energy region below 100 keV. Previous measurements or Monte-Carlo simulations have…
Confocal x-ray fluorescence microscopy (CXRF) allows direct detection of x-ray fluorescence from a micron-scale 3D volume of an extended, unthinned sample. We have previously demonstrated the use of a novel collection optic, fabricated from…
The design and evaluation on the NSLS-II beamline of the 3FI application specific integrated circuit (ASIC) bump-bonded to a simply, planar, two-dimensionally segmented silicon sensor is presented. The ASIC was developed for Full-Field…
The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$\beta$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a…
We present a massively parallel, 3D phase-field simulation framework for modeling ferro-electric materials based scalable logic devices. We self-consistently solve the time-dependent Ginzburg Landau (TDGL) equation for ferroelectric…
We present a Python module for simulating Silicon Photo-Multipliers, Avalanche Photo-Diodes, and Multi-Pixel Photon Counters. This module allows users to perform noise analyses: Dark Count Rate, crosstalk, and afterpulsing. Furthermore, the…
The sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external gamma-radiation. Segmented germanium detectors can be used to identify photons and thus reduce…
To reduce background in experiments looking for rare events, such as the GERDA double beta decay experiment, it is necessary to employ active background-suppression techniques. One of such techniques is the pulse shape analysis of signals…
The GERmanium Detector Array, GERDA, is designed for the search for ``neutrinoless double beta decay'' (0-nu-2-beta) with germanium detectors enriched in Ge76. An 18-fold segmented prototype detector for GERDA Phase II was exposed to an…
We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3 $\times$ 10$^5$ e$^- $/(s$\cdot$cm$^2$). So far, all studies with multiplexed Micromegas…
Space-based gamma-ray telescopes such as the Fermi Large Area Telescope have used single sided silicon strip detectors to measure the position of charged particles produced by incident gamma rays with high resolution. At energies in the…
Events from alpha interactions on the surfaces of germanium detectors are a major contribution to the background in germanium-based searches for neutrinoless double-beta decay. Surface events are subject to charge trapping, affecting their…
In this study, the germanium detector assembly, installed at the Accurate Neutron-Nuclear Reaction measurement Instruments (ANNRI) in the Material and Life Science Facility (MLF) operated by the Japan Proton Accelerator Research Complex…
Mainly due to their outstanding performance the position sensitive silicon detectors are widely used in the tracking systems of High Energy Physics experiments such as the ALICE, ATLAS, CMS and LHCb at LHC, the world's largest particle…
Space-based gamma-ray telescopes such as the Fermi Large Area Telescope have used single sided silicon strip detectors to track secondary charged particles produced by primary gamma-rays with high resolution. At the lower energies targeted…
Experiments built to search for neutrinoless double beta-decay are limited in their sensitivity not only by the exposure but also by the amount of background encountered. Radioactive isotopes in the surrounding of the detectors which emit…
The goal of the TANGERINE project is to develop the next generation of monolithic silicon pixel detectors using a 65 nm CMOS imaging process, which offers a higher logic density and overall lower power consumption compared to previously…