相关论文: Determination of the Energy Characteristics of an …
This paper describes the concept of a primary electron beam facility at CERN, to be used for dark gauge force and light dark matter searches. The electron beam is produced in three stages: A Linac accelerates electrons from a photo-cathode…
Scintillation detectors are essential tools for radiation measurement, but calibrating them accurately can be challenging, especially when full-energy peaks are not prominent. This is common in detectors like plastic scintillators. Current…
The International Linear Collider (ILC) is a future electron/positron collider at the energy frontier. Its physics goals are clearly focused on precision measurements at the electroweak scale and beyond. Beam energy and beam polarisation…
The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe to the short range correlation in atomic nuclei. The energy of the $\gamma$-rays can be measured by collecting the…
Ultralow emittance ($\leq20$ nm, normalized) electron beams with $10^5$ electrons per bunch are obtained by tightly focusing an ultrafast ($\sim$ 100 fs) laser pulse on the cathode of a 1.6 cell radiofrequency photoinjector. Taking…
We describe the work carried out at MPIK to design, model, build and characterize a prototype cell filled with a novel indium-loaded scintillator of interest for real-time low energy solar neutrino spectroscopy. First, light propagation in…
The proton light output function in electron-equivalent energy of various scintillators based on linear alkylbenzene (LAB) has been measured in the energy range from 1 MeV to 17.15 MeV for the first time. The measurement was performed at…
To measure the energy spread of a energy electron beam up to $5 GeV$ in a single shoot measurement the possible applications of an existing magnet as spectrometer has been discussed. For distinguishing the energy resolution and an optimal…
Organic scintillators are often chosen as radiation detectors for their fast decay time and their low Z, while inorganic ones are used when high light ields are required. In this paper we show that a para-terphenyl based detector has a…
The energy-spread of the triple-pulse electron beam generated by the Dragon-II linear induction accelerator is measured using the method of energy dispersion in the magnetic field. A sector magnet is applied for energy analyzing of the…
Using scanning gate microscopy (SGM), we probe the scattering between a beam of electrons and a two-dimensional electron gas (2DEG) as a function of the beam's injection energy, and distance from the injection point. At low injection…
A calorimetric detector for minimally disruptive measurements of atomic hydrogen beams is described. The calorimeter measures heat released by the recombination of hydrogen atoms into molecules on a thin wire. As a demonstration, the…
The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron…
The purpose of this study was to investigate the feasibility of extracting proton beams with two distinct energies within a single synchrotron cycle. The energy difference between the beams should be sufficient to use one beam as a range…
We report a laser wakefield acceleration of electron beams up to 130 MeV from laser-driven 4-mm long nitrogen gas jet. By using a moderate laser intensity (3.5*10^18 W.cm^(-2)) and relatively low plasma densities (0.8*10^18 cm^(-3) to…
A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of…
We measure and explain scintillator non-proportionality and gamma quenching of CaWO4 at low energies and low temperatures. Phonons that are created following an interaction in the scintillating crystal at temperatures of 15mK are used for a…
Fast procedures for the beam quality assessment and for the monitoring of beam energy modulations during the irradiation are among the most urgent improvements in particle therapy. Indeed, the online measurement of the particle beam energy…
The focusing strength of plasma lenses used with high energy electron or positron beams can give rise to synchrotron radiation with critical energies in the MeV range. A method is described for measuring the characteristic energy of this…
The quality of electron beams produced from plasma-based accelerators, i.e., normalized brightness and energy spread, has made transformative progress in the past several decades in both simulation and experiment. Recently, full-scale…