Compact laser-plasma acceleration of fast ions has made great strides since its discovery over two decades ago, resulting in the current generation of high-energy ($\geq 100\,\rm MeV$) ultracold beams over ultrashort ($\leq 1\,\rm ps$)…
Injected beam energy and energy spread are critical parameters affecting the performance of our rapid cycling synchrotron (RCS). A real-time energy monitoring system is being installed to examine the H- beam out of the Intense Pulsed…
A single terbium foil was irradiated with 800 MeV protons to ascertain the potential for production of lanthanide isotopes of interest in medical, astrophysical, and basic science research and to contribute to nuclear data repositories.…
A design study has been performed for a positron beam with an energy of 500 MeV to be realized at the applied physics area of the Mainz Microtron MAMI. Positrons will be created after pair conversion of bremsstrahlung, produced by the 855…
Phase noise (PN) is a critical impairment at D-band frequencies (110 to 170 GHz), which are widely investigated as promising candidates for beyond 5G/6G ISAC systems. This paper evaluates OFDM based ISAC sensing performance under realistic…
A high-resolution beam telescope is essential for the precise characterization of silicon pixel sensors. As part of the CSNS-II upgrade project, a High-Energy Proton Beam Telescope (HEPTel) based on monolithic active pixel sensors (MAPS)…
In proton therapy, depth scanning of the irradiated object is performed by changing the Output Energy (OE) of the accelerated beam. In pulsed linear accelerators, adjustment of the OE is usually by changing the amplitude and/or phase of the…
The 1.7-GeV 100-mA CW proton linac is now under design for the Accelerator Production of Tritium (APT) Project. The APT linac comprises both the normal conducting (below 211 MeV) and superconducting (SC) sections. The high current leads to…
Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the…
The Proton Improvement Plan-II (PIP-II) [1] has been developed at Fermilab to provide powerful proton beams to the laboratorys experiments. An 800-MeV superconducting linear accelerator-a centerpiece of the project-is currently under…
In this study, a low energy beam transport (LEBT) channel for the proton linac section of the Turkic Accelerator Complex (TAC) has been designed by using TRACE 2D and TRAVEL codes. The LEBT channel is located between an ion source and a…
Laser-driven ion acceleration provides ultra-short, high-charge, low-emittance beams, which are desirable for a wide range of high-impact applications. Yet after decades of research, a significant increase in maximum ion energy is still…
The Fermilab Proton Source machines, constituted by Pre-Injector, conventional Linac and Booster synchrotron, at Fermi National Accelerator Laboratory (Fermilab) had have a long history of successful beam operations. Built in late '60s, the…
Although accelerator technology has matured sufficiently, state-of-the-art X-ray linacs for radiotherapy and cargo-scanning capture merely 30-50% of the electrons from a thermionic cathode, requiring a higher cathode current and leaving…
In this paper, electromagnetic emissions produced by a beam-plasma system are investigated using particle-in-cell simulations for the particular case when the typical transverse size of both 100 keV electron beam and produced plasma channel…
The idea of using fixed-target annihilations of a high-energy positron beam on a target for producing a new, very feebly interacting particle has been exploited by the PADME experiment at LNF using the extracted beam from the LINAC in the…
The Fermilab Linac delivers a variable intensity, 400-MeV beam to the The MuCool Test Area experimental hall via a beam line specifically designed to facilitate measurements of the Linac beam emittance and properties. A 10 m,…
We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match $50\,\Omega$ and its response has…
We present the development of a high power fibre laser system to investigate its suitability for use in a transverse electron beam profile monitor i.e. a laserwire. A system capable of producing individual pulses up to $165.8 \pm 0.4 \mu$J…
We report a laser wakefield acceleration of electron beams up to 130 MeV from laser-driven 4-mm long nitrogen gas jet. By using a moderate laser intensity (3.5*10^18 W.cm^(-2)) and relatively low plasma densities (0.8*10^18 cm^(-3) to…