相关论文: A 100 ps TOF Detection System for On-Line Range- M…
The Time-of-Flight (ToF) technique coupled with semiconductor-like detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full…
For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray…
A pulse oximeter is an optical device that monitors tissue oxygenation levels. Traditionally, these devices estimate the oxygenation level by measuring the intensity of the transmitted light through the tissue and are embedded into everyday…
Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and $\gamma$-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a…
Particle identification (PID) capabilities are studied by using the Time Projection Chamber (TPC) and a Time-Of-Flight (TOF) detector together at STAR. The identification capability of charged hadrons is greatly extended compared with that…
The small time gap of synchrotron radiation in conventional multi-bunch mode (100-500MHz) is prohibitive for time-of-flight (ToF) based electron spectroscopy. Even the new generation of delay-line detectors with improved time resolution…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified…
The High-Acceptance DiElectron Spectrometer (HADES) at GSI Darmstadt consists of a 6-coil toroidal magnet centered on the beam axis and six identical detection sections located between the coils and covering polar angles between $18^\circ$…
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation…
Prostate cancer is the most common disease in men and the second leading cause of death from cancer. Generic large imaging instruments used in cancer diagnosis have sensitivity, spatial resolution, and contrast inadequate for the task of…
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental…
Superconducting nanowire single photon detectors (SNSPDs) emerged in the last decade as a disruptive technology that features performance characteristics, such as high sensitivity, dynamic range and temporal accuracy, which are ideally…
Objective: Proton therapy is a precision-focused cancer treatment where accurate proton beam range monitoring is critical to ensure effective dose delivery. This can be achieved by prompt gamma detection with a Compton camera like the…
In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF…
The barrel time-of-flight (TOF) detector for the PANDA experiment at FAIR in Darmstadt is planned as a scintillator tile hodoscope (SciTil) using 8000 small scintillator tiles. It will provide fast event timing for a software trigger in the…
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight information is used to improve the image reconstruction process. In Time of Flight PET (TOF-PET), fast detectors are able to measure the difference in the arrival…
Prompt Gamma Timing (PGT) is a promising technique for in vivo range verification in particle therapy, exploiting the time-of-flight between primary particles and prompt gamma rays emitted by nuclear interactions. PGT distribution is highly…
Proton radiotherapy promises accurate dose delivery to a tumor and minimal dose deposition to all other tissues. However, in practice the planned dose distribution may not conform to the actual one due to noisy data and different types of…
In this work, we propose a novel technique for in-vivo proton therapy range verification. This technique makes use of a small hadron tumour marker, $^{92}$Mo, implanted at a short known distance from the clinical treatment volume. Signals…