In papers on cold field electron emission from large area field emitters (LAFEs), it has become widespread practice to publish a misleading Fowler-Nordheim-type (FN-type) equation. This equation over-predicts the LAFE-average current…
This paper describes a simple quantitative test applicable to current-voltage data for cold field electron emission (CFE). It can decide whether individual reported field-enhancement-factor (FEF) values are spuriously large. The paper…
This work presents a theoretical explanation for a crossover in the linear behavior in Fowler-Nordheim (FN) plots based on cold field electron emission (CFE) experimental data. It is characterized by a clear change in the decay rate of…
This article proposes that we should think differently about predicting and interpreting measured field electron emission (FE) current-voltage [I(V)] characteristics. It is commonly assumed that I(V) data interpretation is a problem in…
In field electron emission (FE) studies, it is important to check and analyse the quality and validity of experimental current-voltage data, which is usually plotted in one of a small number of standard forms. These include the so-called…
Both single emitters and large area field emitters (LAFE) are generally characterized using the slope and intercept of a Murphy-Good (or Fowler-Nordheim) plot which are used to extract the field enhancement factor and the emission area.…
With a large-area field electron emitter, when an individual post-like emitter is sufficiently resistive, and current through it sufficiently large, then voltage loss occurs along it. This Letter provides a simple analytical and conceptual…
The commonest method of characterizing a cold field electron emitter is to measure its current-voltage characteristics, and the commonest method of analysing these characteristics is by means of a Fowler-Nordheim (FN) plot. This…
Representing field emission data on a Fowler--Nordheim plot is both very common and strongly not recommended. It leads to a spurious estimation of the emitter parameters despite a very good data fit. There is a lack of a reliable method of…
Electrostatic shielding is an important consideration for large area field emitters (LAFE) and results in a distribution of field enhancement factors even when the constituent emitters are identical. Ideally, the mean and variance together…
In field electron emission (FE) studies, it is important to check and analyse the quality and validity of results experimentally obtained from samples, using suitably plotted current-voltage [I(V)] measurements. For the traditional plotting…
Measured field electron emission (FE) current-voltage Im(Vm) data are traditionally analysed via Fowler-Nordheim (FN) plots, as ln{Im/(Vm)**2} vs 1/Vm. These have been used since 1929, because in 1928 FN predicted they would be linear. In…
Field electron emission (FE) has relevance in many different technological contexts. However, many related technological papers use a physically defective elementary FE equation for local emission current density (LECD). This equation takes…
In field electron emission (FE) studies, to interpret current-voltage data and extract characterization parameters, we use smooth planar metal-like emitter (SPME) methodology and a data-analysis plot. Three types exist: Millikan-Lauritsen…
In this dissertation, we analytically study the apex field enhancement factor (FEF), $\gamma_a$, by constructing a method which consists in minimizing an error function defined as to measure the deviation of the potential at the boundary,…
Field emission formulae, current-voltage characteristics and energy distribution of emitted electrons, are derived analytically for a nonplanar (hyperboloidal) metallic emitter model. The traditional Fowler-Nordheim formulae, which are…
It is well known that sufficiently strong electrostatic fields are able to change the morphology of Large Area Field Emitters (LAFEs). This phenomenon affects the electrostatic interactions between adjacent sites on a LAFE during field…
This work considers the effects of the Hurst exponent ($H$) on the local electric field distribution and the slope of the Fowler-Nordheim (FN) plot when considering the cold field electron emission properties of rough Large-Area Conducting…
This paper presents a new methodology for making comparisons between the theory of field electron emission (FE) and experiment, and is intended as a "demonstration of concept". This methodology is based on the value of the exponent kappa…
This article introduces an improved approach to Fowler-Nordheim (FN) plot analysis, based on a new type of intercept correction factor. This factor is more cleanly defined than the factor previously used. General enabling theory is given…