中文
相关论文

相关论文: Fast LLMMSE filter for low-dose CT imaging

200 篇论文

Low-Dose Computed Tomography (LDCT) technique, which reduces the radiation harm to human bodies, is now attracting increasing interest in the medical imaging field. As the image quality is degraded by low dose radiation, LDCT exams require…

图像与视频处理 · 电气工程与系统科学 2022-04-19 Liutao Yang , Zhongnian Li , Rongjun Ge , Junyong Zhao , Haipeng Si , Daoqiang Zhang

Computed Tomography (CT) is a vital diagnostic tool in clinical practice, yet the health risks associated with ionizing radiation cannot be overlooked. Low-dose CT (LDCT) helps mitigate radiation exposure but simultaneously leads to reduced…

计算机视觉与模式识别 · 计算机科学 2025-11-20 Guoliang Gong , Man Yu

Low-dose Computed Tomography (LDCT) reconstruction is an important task in medical image analysis. Recent years have seen many deep learning based methods, proved to be effective in this area. However, these methods mostly follow a…

图像与视频处理 · 电气工程与系统科学 2023-02-08 Runyi Li

Limited data and low dose constraints are common problems in a variety of tomographic reconstruction paradigms which lead to noisy and incomplete data. Over the past few years sinogram denoising has become an essential pre-processing step…

计算机视觉与模式识别 · 计算机科学 2016-03-15 Faisal Mahmood , Nauman Shahid , Pierre Vandergheynst , Ulf Skoglund

In order to reduce the potential radiation risk, low-dose CT has attracted more and more attention. However, simply lowering the radiation dose will significantly degrade the imaging quality. In this paper, we propose a noise reduction…

医学物理 · 物理学 2016-09-28 Hu Chen , Yi Zhang , Weihua Zhang , Peixi Liao , Ke Li , Jiliu Zhou , Ge Wang

Low-dose computed tomography (LDCT) is an important topic in the field of radiology over the past decades. LDCT reduces ionizing radiation-induced patient health risks but it also results in a low signal-to-noise ratio (SNR) and a potential…

图像与视频处理 · 电气工程与系统科学 2022-10-03 Wenjun Xia , Qing Lyu , Ge Wang

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional…

图像与视频处理 · 电气工程与系统科学 2024-05-24 Feng Wang , Renfang Wang , Hong Qiu

To reduce the potential radiation risk, low-dose CT has attracted much attention. However, simply lowering the radiation dose will lead to significant deterioration of the image quality. In this paper, we propose a noise reduction method…

医学物理 · 物理学 2016-10-04 Hu Chen , Yi Zhang , Weihua Zhang , Peixi Liao , Ke Li , Jiliu Zhou , Ge Wang

Low dose computed tomography (LDCT) has attracted more and more attention in routine clinical diagnosis assessment, therapy planning, etc., which can reduce the dose of X-ray radiation to patients. However, the noise caused by low X-ray…

图像与视频处理 · 电气工程与系统科学 2021-07-06 Zhicheng Zhang , Lequan Yu , Xiaokun Liang , Wei Zhao , Lei Xing

Recently, a number of approaches to low-dose computed tomography (CT) have been developed and deployed in commercialized CT scanners. Tube current reduction is perhaps the most actively explored technology with advanced image reconstruction…

医学物理 · 物理学 2018-09-05 Hoyeon Lee , Jongha Lee , Hyeongseok Kim , Byungchul Cho , Seungryong Cho

Cone Beam Computed Tomography(CBCT) is a now known method to conduct CT imaging. Especially, The Low Dose CT imaging is one of possible options to protect organs of patients when conducting CT imaging. Therefore Low Dose CT imaging can be…

计算机视觉与模式识别 · 计算机科学 2021-04-05 Wooram Kang , Mayank Patwari

Like in many other research fields, recent developments in computational imaging have focused on developing machine learning (ML) approaches to tackle its main challenges. To improve the performance of computational imaging algorithms,…

图像与视频处理 · 电气工程与系统科学 2024-08-16 Maximilian B. Kiss , Ander Biguri , Carola-Bibiane Schönlieb , K. Joost Batenburg , Felix Lucka

Many low-dose CT imaging methods rely on supervised learning, which requires a large number of paired noisy and clean images. However, obtaining paired images in clinical practice is challenging. To address this issue, zero-shot…

图像与视频处理 · 电气工程与系统科学 2025-04-11 Yongyi Shi , Ge Wang

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

图像与视频处理 · 电气工程与系统科学 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

Low-dose computed tomography (LDCT) became a clear trend in radiology with an aspiration to refrain from delivering excessive X-ray radiation to the patients. The reduction of the radiation dose decreases the risks to the patients but…

图像与视频处理 · 电气工程与系统科学 2021-02-05 Elvira Zainulina , Alexey Chernyavskiy , Dmitry V. Dylov

Low-dose CT (LDCT) imaging is widely used to reduce radiation exposure to mitigate high exposure side effects, but often suffers from noise and artifacts that affect diagnostic accuracy. To tackle this issue, deep learning models have been…

计算机视觉与模式识别 · 计算机科学 2025-11-04 Taifour Yousra , Beghdadi Azeddine , Marie Luong , Zuheng Ming

We propose a low complexity, graph based linear minimum mean square error (LMMSE) filter in which the non-white characteristics of a random process are taken into account. Our method corresponds to block LMMSE filtering, and has the…

信息论 · 计算机科学 2014-05-14 Pinar Sen , Ali Ozgur Yilmaz

In the intention of minimizing excessive X-ray radiation administration to patients, low-dose computed tomography (LDCT) has become a distinct trend in radiology. However, while lowering the radiation dose reduces the risk to the patient,…

医学物理 · 物理学 2022-04-12 Long Zhou , Xiaozhuang Wang , Min Hou , Ping Li , Chunlong Fu , Yanjun Ren , Tingting Shao , Xi Hu , Jihong Sun , Hongwei Ye

Low-dose computed tomography (LDCT) offers significant advantages in reducing the potential harm to human bodies. However, reducing the X-ray dose in CT scanning often leads to severe noise and artifacts in the reconstructed images, which…

图像与视频处理 · 电气工程与系统科学 2024-08-27 Ran An , Yinghui Zhang , Xi Chen , Lemeng Li , Ke Chen , Hongwei Li

With the development of deep learning, medical image processing has been widely used to assist clinical research. This paper focuses on the denoising problem of low-dose computed tomography using deep learning. Although low-dose computed…

图像与视频处理 · 电气工程与系统科学 2026-05-19 Zhilin Guan , Wei Zhang
‹ 上一页 1 2 3 10 下一页 ›