相关论文: Reduction of coherent betatron oscillations in a m…
A new experiment to measure the muon g-2 factor is proposed. We suppose the sensitivity of this experiment to be about 0.03 ppm. The developed experiment can be performed on an ordinary storage ring with a noncontinuous field created by…
Precision measurements of the anomalous magnetic moment of the muon depend on the correct collective mode assignment of the coherent betatron oscillations in the beam. Presently, there is a disagreement between experiment and theory for the…
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3$\sigma$ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140…
We calculate the corrections for constant radial magnetic field in muon g--2 and electric-dipole-moment experiments in storage rings. While the correction is negligible for the current generation of g--2 experiments, it affects the upcoming…
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_\mu \equiv (g_\mu-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of…
This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $\omega_a^m$ are associated with…
We propose to use slow muons facilities combined with cyclotron radiation detection for precision test of the weak interaction in the muon decays. Slow positive muon bunches are first injected into a cylindrical superconducting vacuum…
Muons have a similar latency/energy correlation from pion decay as do the neutrinos, and hence in each time-slice in a stroboscopic analysis measurements of their momentum spectra can reduce systematic uncertainties due to flux. There are,…
The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab has a goal of measuring the muon anomaly ($a_\mu$) with unprecedented precision using positive muons. This measurement is motivated by the difference between the previous Brookhaven…
The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_\mu = (g^{}_\mu-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018.…
The crucial limitation of improving the sensitivity of the detection of weak magnetic fields is the unavoidable measurement noise. In this paper, we propose a scheme to achieve precise sensing robust against additional noise by employing a…
The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The Muon g-2/EDM Experiment at J-PARC will employ a novel way to measure the muon magnetic anomaly, a_mu = (g-2)_mu/2, by using a low-emittance beam of positive muons stored in a compact muon storage magnet. The experimental method includes…
Traditional analysis of $g=2(1+\kappa )$ experiments for charged leptons use a classical spin vector picture. For muons, we here employ a more exact Dirac quantum four component spinor theory. Survival probabilities (including wave packet…
We derive in full generality the equations that govern the time dependence of the energy ${\mathcal E}$ of the decay electrons in a muon $g-2$ experiment. We include both electromagnetic and gravitational effects and we estimate possible…
A new superferric magnetic storage ring with highly homogeneous field at 1.45 T and weak electrostatic focussing is described which has been set up at the Brookhaven National Laboratory (BNL), USA, for a precision measurement of the…
A new measurement of the positive muon's anomalous magnetic moment has been made at the Brookhaven Alternating Gradient Synchrotron using the direct injection of polarized muons into the superferric storage ring. The angular frequency…
The 3.6 \sigma discrepancy between the predicted and measured values of the anomalous magnetic moment of positive muons can be explained by the existence of a new dark boson Z_\mu with a mass in the sub-GeV range, which is coupled…
The Mu2e experiment measures the conversion rate of muons into electrons and the Muon g-2 experiment measures the muon magnetic moment. Both experiments require 53 MHz batches of 8 GeV protons to be re-bunched into 150 ns, 2.5 MHz pulses…