中文
相关论文

相关论文: Expected performance of the TT-PET scanner

200 篇论文

Positron emission tomography (PET) is a medical imaging method based on the measurement of concentrations of positron-emitting radionuclides in a living body. In the PET imaging system, glucose is labeled with a positron-emitting…

信号处理 · 电气工程与系统科学 2022-09-27 Mehmet Akif Ozdemir , Ali Tangel

We present a novel FPGA-based bismuth germanate (BGO) time-of-flight (TOF) digitizer, implemented on an FPGA (VC707 evaluation kit, Xilinx). This digitizer was designed to address the recently highlighted characteristics of BGO, which…

仪器与探测器 · 物理学 2024-10-15 Daehee Lee , Sun Il Kwon

The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data- taking with…

仪器与探测器 · 物理学 2012-08-27 The ATLAS Collaboration

Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial…

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative…

仪器与探测器 · 物理学 2021-04-08 L. Bläckberg , S. Sajedi , G. El Fakhri , H. Sabet

Objective. This study investigates the best achievable performance of a brain-dedicated PET system with high resolution and sensitivity by evaluating different detector configurations, while maintaining a practical system design suitable…

医学物理 · 物理学 2026-02-26 Yuemeng Feng , Lisa Blackberg , Arkadiusz Sitek , Hamid Sabet

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

仪器与探测器 · 物理学 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

This master thesis presents a new type of Positron Emission TOF Apparatus using Liquid xenOn (PETALO). The detector is based in the Liquid Xenon Scintillating Cell (LXSC). The cell is a box filled with liquid xenon (LXe) whose transverse…

医学物理 · 物理学 2016-06-01 J. M. Benlloch-Rodriguez

Positron Emission Tomography (PET) enables functional imaging of deep brain structures, but the bulk and weight of current systems preclude their use during many natural human activities, such as locomotion. The proposed long-term solution…

机器人学 · 计算机科学 2023-12-07 Junxiang Wang , Ti Wu , Iulian I. Iordachita , Peter Kazanzides

Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…

仪器与探测器 · 物理学 2026-05-14 Ziyi Yang , Xiyang Wang , Shiming Zou , Ting Wang , Kairui Huang , Wanyi Zhuang , Yicheng Pu , Xiaolong Wang

Improving the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) systems to achieve a higher signal-to-noise ratio (SNR) gain or even direct positron emission imaging (dPEI) is of paramount importance…

An ever-increasing demand for high-performance silicon sensors requires complex sensor designs that are challenging to simulate and model. The combination of electrostatic finite element simulations with a transient Monte Carlo approach…

New detector approaches in Positron Emission Tomography imaging will play an important role in reducing costs, lowering administered radiation doses, and improving overall performance. PETALO employs liquid xenon as the active scintillating…

Fully Field Programmable Gate Array (FPGA)based digitizer for high-resolution time and energy measurement is an attractive low cost solution for the readout electronics in positron emission computed tomography (PET)detector. In recent…

仪器与探测器 · 物理学 2022-01-07 Cong Ma , Wubin Wang , Xiaokun Zhao , Li Yu , Guocheng Wu

The fast scintillation decay time and the high scintillation yield of liquid xenon makes it an appropriate material for nuclear medicine. Moreover, being a continuous medium with a uniform response, liquid xenon allows one to avoid most of…

The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the…

A Time to Digital Converter was designed (CMOS 0.35 $\mum) in order to be used in Liquid Xenon PET prototype. The circuit proved to be able to work at -120 degrees C, while showing a resolution of 250 ps. The circuit enables a low readout…

仪器与探测器 · 物理学 2007-05-23 O. Bourrion , L. Gallin-Martel

Total Body PET (TBPET) scanners have recently demonstrated the ability to significantly reduce both acquisition time and the administered radioactive dose, thanks to their increased sensitivity. However, their widespread adoption is limited…

Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low…