相关论文: First performance evaluation of a Multi-layer Thic…
We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron…
We constructed and operated a double phase (liquid-vapour) pure argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) with a sensitive area of 10x10 cm$^2$ and up to 30 cm of drift length. The LEM is a macroscopic hole…
The performance of triple-GEM detectors in He+N2 gas mixtures is studied in the range of 1-10 atm. The results obtained are relevant in the field of minimization of ionic space-charge effect in the TPC and neutron detection.
This paper shows the simulation and test results of 50um thick Low Gain Avalanche Detectors (LGAD) sensors designed by the Institute of High Energy Physics (IHEP) and fabricated by the Institute of Microelectronics of the Chinese Academy of…
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…
We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…
A novel concept of optical signal recording in two-phase avalanche detectors, with Geiger-mode Avalanche Photodiodes (G-APD) is described. Avalanche-scintillation photons were measured in a thick Gas Electron Multiplier (THGEM) in view of…
The THGEMs based on ceramic substrate were developed successfully for neutron and single photon detection. The influences on thermal neutron scattering and the internal radioactivity of both ceramic and FR-4 substrates were studied and…
The Large Electron Multipliers (LEMs) are key components of double phase liquid argon TPCs. The drifting charges after being extracted from the liquid are amplified in the LEM positioned half a centimeter above the liquid in pure argon…
A prototype detector is being developed which combines the functions of a Time Projection Chamber for charged particle tracking and a Cherenkov detector for particle identification. The TPC consists of a 10x10x10 cm3 drift volume where the…
In this study we investigate the stability limits of Micromegas detectors upon irradiation with alpha particles. The results are obtained with meshes with different optical transparency and geometry of wires. The measurements are performed…
To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…
The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search…
Sensitivities of current directional dark matter search detectors using gas time projection chambers are now constrained by target mass. A ton-scale gas TPC detector will require large charge readout areas. We present a first demonstration…
Gas Electron Multipliers (GEMs) can be produced in large foils and molded in different shapes. The possibility to create cylindrical layers has opened the opportunity to use such detector as internal tracker at collider experiments. One…
The ALICE experiment at LHC has planned to upgrade the TPC by replacing the MWPC with GEM based detecting elements to restrict the IBF to a tolerable value. However the variation of the gain as a function of physical parameters of…
The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…
The Multi-Chip-Module-Deposited (MCM-D) technique has been used to build hybrid pixel detector assemblies. This paper summarises the results of an analysis of data obtained in a test beam campaign at CERN. Here, single chip hybrids made of…
We study the feedback of positive ions in triple and quadruple Gas Electron Multiplier (GEM) detectors. The effects of GEM hole diameter, detector gain, applied voltages, number of GEMs and other parameters on ion feedback are investigated…