相关论文: Optimization of the light intensity for Photodetec…
Detection of low-intensity light relies on the conversion of photons to photoelectrons, which are then multiplied and detected as an electrical signal. To measure the actual intensity of the light, one must know the factor by which the…
We present two methods for determining the absolute detection efficiency of photon-counting detectors directly from their singles rates under illumination from a nonclassical light source. One method is based on a continuous variable…
In many applications, such as the detection of ultra-high energy cosmic rays using the air fluorescence method, the number of photons incident on the detector must be known. This requires a precise knowledge of the absolute efficiency of…
Intensity correlation measurements form the basis of many experiments based on spontaneous parametric down-conversion. In the most common situation, two single-photon avalanche diodes and coincidence electronics are used in the detection of…
Single-photon detectors are ``blind" after the detection of a photon, and thereafter display a characteristic recovery in efficiency, during which the number of undetected photons depends on the statistics of the incident light. We show how…
We analyse the capability of distinguishing between different intensities in a monochromatic, pixellated image acquisition system at low light intensities. In practice, the latter means that each pixel detects a countable number of photons…
Detector counting rate nonlinearity, though a known problem, is commonly ignored in the analysis of angle resolved photoemission spectroscopy where modern multichannel electron detection schemes using analog intensity scales are used. We…
The accurate calibration of photomultiplier tubes is critical in a wide variety of applications for which it is necessary to know the absolute number of detected photons or precisely determine the resolution of the signal. Conventional…
Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector's resolution is larger than the energy of a single photon, a…
Absorption imaging of ultracold atoms is the foundation for quantitative extraction of information from experiments with ultracold atoms. Due to the limited exposure time available in these systems, the signal-to-noise ratio is largest for…
We derive a computationally efficient expression of the photon counting distribution for a uniformly illuminated array of single photon detectors. The expression takes the number of single detectors, their quantum efficiency, and their…
The electrical 3 dB bandwidth is regularly used as a measure for the response speed of a photodetector and is estimated via various approaches in literature, ranging from direct measurements to gauged values via approximations. Great care…
We report a measurement workflow free of systematic errors consisting of a reconfigurable photon-number-resolving detector, custom electronic circuitry, and faithful data-processing algorithm. We achieve unprecedentedly accurate measurement…
Current parameter estimation techniques rely on photodetectors which have low brightness and thus are based on gathering averaged statistics. Recently it was claimed that perfect photodetction will change the nature of sensing algorithms…
We discuss in depth the validity and limitations of a theoretical scheme to evaluate photo-electron spectra (PES) through collecting the phase oscillations at a given measuring point. Problems appear if the laser pulse is still active when…
The fidelity of postselecting devices based on direct photon number detection can be significantly improved by insertion of a phase-insensitive optical amplifier in front of the detector. The scheme is simple, and the cost to the…
Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the ombined effects of all detector components in a single measurement. The calibrated 2.5…
We demonstrate a novel procedure to calibrate neutron detection systems commonly used in standard neutron radiography. This calibration allows determining the uncertainties due to Poisson-like neutron counting statistics for each individual…
For optical phase estimation via homodyne measurement, we generalize the theory from detector's linear to nonlinear response regime, which accounts for the presence of saturation effect. For optical coherent light, we carry out analytic…
We present experimental results on a method to perform polarimetry on ensembles of single photons. Our setup is based on a measurement method known to be optimal for estimating the state of two level systems. The setup has no moving parts…