中文
相关论文

相关论文: Ultra-sensitive SQUID systems for pulsed fields - …

200 篇论文

The requirements for the construction of ultra-sensitive SQUID instrumentation as used in biomagnetism are presented. Typically, SQUIDs are inductively coupled to pick-up coils and for this arrangement one can improve the noise performance…

仪器与探测器 · 物理学 2019-03-25 Rainer Körber

The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We…

仪器与探测器 · 物理学 2017-02-20 Jan-Hendrik Storm , Peter Hömmen , Dietmar Drung , Rainer Körber

We study superconducting stripline resonator (SSR) made of Niobium, which is integrated with a superconducting interference device (SQUID). The large nonlinear inductance of the SQUID gives rise to strong Kerr nonlinearity in the response…

超导电性 · 物理学 2009-10-21 Oren Suchoi , Baleegh Abdo , Eran Segev , Oleg Shtempluck , M. P. Blencowe , Eyal Buks

A particular superconducting quantum interference device (SQUID)qubit, indicated as double SQUID qubit, can be manipulated by rapidly modifying its potential with the application of fast flux pulses. In this system we observe coherent…

超导电性 · 物理学 2012-05-08 F. Chiarello , E. Paladino , M. G. Castellano , C. Cosmelli , A. D'Arrigo , G. Torrioli , G. Falci

We investigate electric transport and noise properties of microstrip-type submicron direct current superconducting quantum interference devices (dc SQUIDs) based on Nb thin films and overdamped Josephson junctions with a HfTi barrier. The…

We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a…

We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and…

仪器与探测器 · 物理学 2017-08-29 Jan-Hendrik Storm , Dietmar Drung , Martin Burghoff , Rainer Körber

Micron size superconducting quantum interference devices ($\mu$-SQUID) of lead (Pb), for probing nano-magnetism, were fabricated and characterized. In order to get continuous Pb films with small grain size, Pb was thermally evaporated on a…

超导电性 · 物理学 2021-12-06 Sagar Paul , Sourav Biswas , Anjan K. Gupta

We report on the development of an ultralow noise thin-film based SQUID magnetometer. A niobium thin-film pickup coil is connected to the input coil of a SQUID current sensor. The low capacitance of the used sub-micrometer cross-type…

仪器与探测器 · 物理学 2017-05-18 M. Schmelz , V. Zakosarenko , A. Chwala , T. Schönau , R. Stolz , S. Anders , S. Linzen , H. -G. Meyer

We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions…

超导电性 · 物理学 2015-05-28 J. Nagel , O. F. Kieler , T. Weimann , R. Wölbing , J. Kohlmann , A. B. Zorin , R. Kleiner , D. Koelle , M. Kemmler

We present results on ultra low noise YBa$_2$Cu$_3$O$_{7-\delta}$ nano Superconducting QUantum Interference Devices (nanoSQUIDs). To realize such devices, we implemented high quality YBCO nanowires, working as weak links between two…

We present spiral resonators of thin film niobium (Nb) that exhibit large geometric inductance, high critical magnetic fields and high single photon quality factors. These low loss geometric inductors can be a compelling alternative to…

量子物理 · 物理学 2025-05-26 M. Medahinne , Y. P. Kandel , S. Thapa Magar , E. Champion , J. M. Nichol , M. S. Blok

We report on the development of highly sensitive SQUIDs featuring sub-micrometer loop dimensions. The integration of high quality and low capacitance SIS Nb/AlOx/Nb cross-type Josephson tunnel junctions results in white flux noise levels as…

超导电性 · 物理学 2015-01-06 M. Schmelz , Y. Matsui , R. Stolz , V. Zakosarenko , T. Schönau , S. Anders , S. Linzen , H. Itozaki , H. -G. Meyer

We have fabricated arrays of High-T$_c$ Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive antennas for Radio-Frequency (RF) waves. These sub-wavelength size devices known as…

Superconducting Quantum Interference Devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pick-up loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with…

Superconducting quantum interference devices (SQUIDs) are among the most sensitive detectors for out-of-plane magnetic field components. However, due to their periodic response with short modulation period $M = 1 \Phi_0$, determined by the…

The performance of superconducting devices like qubits, SQUIDs, and particle detectors is often limited by finite coherence times and 1/f noise. Various types of slow fluctuators in the Josephson junctions and the passive parts of these…

Superconducting devices based on the Josephson effect are effectively used for the implementation of qubits and quantum gates. The manipulation of superconducting qubits is generally performed by using microwave pulses with frequencies from…

超导电性 · 物理学 2015-05-14 M G Castellano , F Chiarello , P Carelli , C Cosmelli , F Mattioli , G Torrioli

We report on the development of nearly quantum limited SQUIDs with miniature pickup loop dimensions. The implemented high quality and low capacitance cross-type Nb/AlOx/Nb Josephson junctions offer large $I_CR_N$-products and therefore…

超导电性 · 物理学 2017-05-18 M. Schmelz , V. Zakosarenko , T. Schönau , S. Anders , S. Linzen , R. Stolz , H. -G. Meyer

We have studied the impact of low-frequency magnetic flux noise upon superconducting transmon qubits with various levels of tunability. We find that qubits with weaker tunability exhibit dephasing that is less sensitive to flux noise. This…

‹ 上一页 1 2 3 10 下一页 ›