中文
相关论文

相关论文: Construction and Performance of the Barrel Electro…

200 篇论文

The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number…

仪器与探测器 · 物理学 2009-11-13 M. Barbi

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO$_{\rm 4}$ scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The high-granularity, high-resolution…

仪器与探测器 · 物理学 2025-10-07 Alexander Somov

The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are…

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a…

仪器与探测器 · 物理学 2022-03-17 S. Adhikari , C. S. Akondi , H. Al Ghoul , A. Ali , M. Amaryan , E. G. Anassontzis , A. Austregesilo , F. Barbosa , J. Barlow , A. Barnes , E. Barriga , R. Barsotti , T. D. Beattie , J. Benesch , V. V. Berdnikov , G. Biallas , T. Black , W. Boeglin , P. Brindza , W. J. Briscoe , T. Britton , J. Brock , W. K. Brooks , B. E. Cannon , C. Carlin , D. S. Carman , T. Carstens , N. Cao , O. Chernyshov , E. Chudakov , S. Cole , O. Cortes , W. D. Crahen , V. Crede , M. M. Dalton , T. Daniels , A. Deur , C. Dickover , S. Dobbs , A. Dolgolenko , R. Dotel , M. Dugger , R. Dzhygadlo , A. Dzierba , H. Egiyan , T. Erbora , A. Ernst , P. Eugenio , C. Fanelli , S. Fegan , A. M. Foda , J. Foote , J. Frye , S. Furletov , L. Gan , A. Gasparian , A. Gerasimov , N. Gevorgyan , C. Gleason , K. Goetzen , A. Goncalves V. S. Goryachev , L. Guo , H. Hakobyan , A. Hamdi , J. Hardin , C. L. Henschel , G. M. Huber , C. Hutton , A. Hurley , P. Ioannou , D. G. Ireland , M. M. Ito , N. S. Jarvis , R. T. Jones , V. Kakoyan , S. Katsaganis , G. Kalicy , M. Kamel , C. D. Keith , F. J. Klein , R. Kliemt , D. Kolybaba , C. Kourkoumelis , S. T. Krueger , S. Kuleshov , I. Larin , D. Lawrence , J. P. Leckey , D. I. Lersch , B. D. Leverington , W. I. Levine , W. Li , B. Liu , K. Livingston , G. J. Lolos , V. Lyubovitskij , D. Mack , H. Marukyan , P. T. Mattione , V. Matveev , M. McCaughan , M. McCracken , W. McGinley , J. McIntyre , D. Meekins , R. Mendez , C. A. Meyer , R. Miskimen , R. E. Mitchell , F. Mokaya , K. Moriya , F. Nerling , L. Ng , H. Ni , A. I. Ostrovidov , Z. Papandreou , M. Patsyuk , C. Paudel , P. Pauli , R. Pedroni , L. Pentchev , K. J. Peters , W. Phelps , J. Pierce , E. Pooser , V. Popov , B. Pratt , Y. Qiang , N. Qin , V. Razmyslovich , J. Reinhold , B. G. Ritchie , J. Ritman , L. Robison , D. Romanov , C. Romero , C. Salgado , N. Sandoval , T. Satogata , A. M. Schertz , S. Schadmand , A. Schick , R. A. Schumacher , C. Schwarz , J. Schwiening , A. Yu. Semenov , I. A. Semenova , K. K. Seth , X. Shen , M. R. Shepherd , E. S. Smith , D. I. Sober , A. Somov , S. Somov , O. Soto , N. Sparks , M. J. Staib , C. Stanislav , J. R. Stevens , J. Stewart , I. I. Strakovsky , B. C. L. Summner , K. Suresh , V. V. Tarasov , S. Taylor , L. A. Teigrob , A. Teymurazyan , A. Thiel , I. Tolstukhin , A. Tomaradze , A. Toro , A. Tsaris , Y. Van Haarlem , G. Vasileiadis , I. Vega , G. Visser , G. Voulgaris , N. K. Walford , D. Werthmüller , T. Whitlatch , N. Wickramaarachchi , M. Williams , E. Wolin , T. Xiao , Y. Yang , J. Zarling , Z. Zhang , Q. Zhou , X. Zhou , B. Zihlmann

A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO$_4$) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses…

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) - a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) - was tested in a dedicated beam campaign at the…

The Electromagnetic Calorimeter (ECAL), consisting of 1,596 lead tungstate scintillating crystals, has been recently constructed and installed in Experimental Hall D at Jefferson Lab (JLab). The calorimeter is a key component of the JLab…

仪器与探测器 · 物理学 2025-10-07 Alexander Somov , Vladimir Berdnikov

We report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron…

The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at $\sqrt{s}$ = 13 TeV at the CERN LHC, in the years from 2015 to 2018 (LHC Run 2),…

仪器与探测器 · 物理学 2024-09-06 CMS Collaboration

The electromagnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with high resolution. The current status of the calorimeter, now in its seventh year…

仪器与探测器 · 物理学 2019-08-14 Johannes M. Bauer

A prototype Silicon-Tungsten electromagnetic calorimeter (ECAL) for an International Linear Collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had 6480 silicon pads of dimension 1x1 cm^2.…

仪器与探测器 · 物理学 2017-07-24 CALICE Collaboration

A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…

仪器与探测器 · 物理学 2010-07-16 Adil Khan

We report the design and performance of the hybrid electromagnetic calorimeter consisting of 1152 $PbWO_4$ crystals and 576 lead glass blocks for the PrimEx experiment at the Jefferson Laboratory. The detector was built for high precision…

仪器与探测器 · 物理学 2019-08-14 M. Kubantsev , I. Larin , A. Gasparyan

We describe the electromagnetic calorimeter built for the GRAAL apparatus at the ESRF. Its monitoring system is presented in detail. Results from tests and the performance obtained during the first GRAAL experiments are given. The energy…

In the ILD detector, HCAL is inside the coil. The HCAL is about 5 interaction length thick, and ECAL is about 1 interaction length thick. For example, an eighty GeV hadron, it is only 95% energy will be contained in ECAL plus HCAL. We need…

仪器与探测器 · 物理学 2019-08-13 Shaojun Lu

The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the…

核实验 · 物理学 2016-05-30 The GlueX Collaboration , H. Al Ghoul , E. G. Anassontzis , F. Barbosa , A. Barnes , T. D. Beattie , D. W. Bennett , V. V. Berdnikov , T. Black , W. Boeglin , W. K. Brooks , B. Cannon , O. Chernyshov , E. Chudakov , V. Crede , M. M. Dalton , A. Deur , S. Dobbs , A. Dolgolenko , M. Dugger , H. Egiyan , P. Eugenio , A. M. Foda , J. Frye , S. Furletov , L. Gan , A. Gasparian , A. Gerasimov , N. Gevorgyan , V. S. Goryachev , B. Guegan , L. Guo , H. Hakobyan , H. Hakobyan2 , J. Hardin , G. M. Huber , D. Ireland , M. M. Ito , N. S. Jarvis , R. T. Jones , V. Kakoyan , M. Kamel , F. J. Klein , C. Kourkoumeli , S. Kuleshov , M. Lara , I. Larin , D. Lawrence , J. Leckey , W. I. Levine , K. Livingston , G. J. Lolos , D. Mack , P. T. Mattione , V. Matveev , M. McCaughan , W. McGinley , J. McIntyre , R. Mendez , C. A. Meyer , R. Miskimen , R. E. Mitchell , F. Mokaya , K. Moriya , G. Nigmatkulov , N. Ochoa , A. I. Ostrovidov , Z. Papandreou , R. Pedroni , M. Pennington , L. Pentchev , A. Ponosov , E. Pooser , B. Pratt , Y. Qiang , J. Reinhold , B. G. Ritchie , L. Robison , D. Romanov , C. Salgado , R. A. Schumacher , A. Yu. Semenov , I. A. Semenova , I. Senderovich , K. K. Seth , M. R. Shepherd , E. S. Smith , D. I. Sober , A. Somov , S. Somov , O. Soto , N. Sparks , M. J. Staib , J. R. Stevens , A. Subedi , V. Tarasov , S. Taylor , I. Tolstukhin , A. Tomaradze , A. Toro , A. Tsaris , G. Vasileiadis , I. Vega , G. Voulgaris , N. K. Walford , T. Whitlatch , M. Williams , E. Wolin , T. Xiao , J. Zarling , B. Zihlmann

A BGO electromagnetic calorimeter (ECAL) is built for the DArk Matter Particle Explorer (DAMPE) mission. The effect of temperature on the BGO ECAL was investigated with a thermal vacuum experiment. The light output of a BGO crystal depends…

A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV…

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…

‹ 上一页 1 2 3 10 下一页 ›