中文
相关论文

相关论文: Automated Setup to Accurately Calibrate Electrical…

200 篇论文

The inductive charging of electric vehicles requires specific measurement and calibration systems. In fact, the measurement of power on board involves DC signals, which are superimposed to a significant AC ripple up to or over 150 kHz,…

仪器与探测器 · 物理学 2019-05-21 M. Zucca , U. Pogliano , M. Modarres , D. Giordano , G. Crotti , D. Serazio

A temperature controlled 1 {\Omega}-10 k{\Omega} standard Resistors transportable setup was developed at National Institute of Metrological Research, (INRIM) for the calibration and adjustment of multifunction electrical instruments. The…

仪器与探测器 · 物理学 2015-05-19 P. P. Capra , F. Galliana

The Laboratory of Metrology in Electrical Standards of Inmetro (Lampe) has built, in 2010, a transformer which is able to perform inductive voltage divider ratio calibrations using the bootstrap method. This transformer was idealized…

仪器与探测器 · 物理学 2019-04-19 Flavio A. Silveira

The capacitance-charging method is a well-established and handy technique for the generation of dc current in the 100 pA range or lower. The method involves a capacitance standard and a sampling voltmeter, highly stable devices easy to…

仪器与探测器 · 物理学 2013-12-09 Luca Callegaro , Pier Paolo Capra , Vincenzo D'Elia , Flavio Galliana

An automated temperature-controlled electrical DC voltage and DC resistance multiple reference standard (MRS) has been developed by Measurements International (MI) with the scientific support from the Istituto Nazionale di Ricerca…

An accurate and extensive Inter-laboratory comparison between the laboratory for the calibration of multifunction electrical instruments of the National Institute of Metrology Research (INRIM) and a secondary high level electrical…

仪器与探测器 · 物理学 2016-04-22 F. Galliana , M. Lanzillotti

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in…

仪器与探测器 · 物理学 2018-05-16 M. Arenz , W. -J. Baek , M. Beck , A. Beglarian , J. Behrens , T. Bergmann , A. Berlev , U. Besserer , K. Blaum , T. Bode , B. Bornschein , L. Bornschein , T. Brunst , N. Buzinsky , S. Chilingaryan , W. Q. Choi , M. Deffert , P. J. Doe , O. Dragoun , G. Drexlin , S. Dyba , F. Edzards , K. Eitel , E. Ellinger , R. Engel , S. Enomoto , M. Erhard , D. Eversheim , M. Fedkevych , S. Fischer , J. A. Formaggio , F. M. Fränkle , G. B. Franklin , F. Friedel , A. Fulst , W. Gil , F. Glück , A. Gonzalez Ureña , S. Grohmann , R. Grössle , R. Gumbsheimer , M. Hackenjos , V. Hannen , F. Harms , N. Haußmann , F. Heizmann , K. Helbing , W. Herz , S. Hickford , D. Hilk , D. Hillesheimer , M. A. Howe , A. Huber , A. Jansen , J. Kellerer , N. Kernert , L. Kippenbrock , M. Kleesiek , M. Klein , A. Kopmann , M. Korzeczek , A. Kovalík , B. Krasch , M. Kraus , L. Kuckert , T. Lasserre , O. Lebeda , J. Letnev , A. Lokhov , M. Machatschek , A. Marsteller , E. L. Martin , S. Mertens , S. Mirz , B. Monreal , H. Neumann , S. Niemes , A. Off , A. Osipowicz , E. Otten , D. S. Parno , A. Pollithy , A. W. P. Poon , F. Priester , P. C. -O. Ranitzsch , O. Rest , R. G. H. Robertson , F. Roccati , C. Rodenbeck , M. Röllig , C. Röttele , M. Ryšavý , R. Sack , A. Saenz , L. Schimpf , K. Schlösser , M. Schlösser , K. Schönung , M. Schrank , H. Seitz-Moskaliuk , J. Sentkerestiová , V. Sibille , M. Slezák , M. Steidl , N. Steinbrink , M. Sturm , M. Suchopar , M. Suesser , H. H. Telle , L. A. Thorne , T. Thümmler , N. Titov , I. Tkachev , N. Trost , K. Valerius , D. Vénos , R. Vianden , A. P. Vizcaya Hernández , M. Weber , C. Weinheimer , C. Weiss , S. Welte , J. Wendel , J. F. Wilkerson , J. Wolf , S. Wüstling , S. Zadoroghny

Modern commercial direct-current current transformers (DCCT) can measure currents up to the kA range with accuracies better than 1E-5. We discuss here a DCCT calibration method and its implementation with commercial instruments typically…

仪器与探测器 · 物理学 2016-11-17 Luca Callegaro , Cristina Cassiago , Enrico Gasparotto

The most common method to measure direct current high voltage (HV) down to the ppm-level is to use resistive high-voltage dividers. Such devices scale the HV into a range where it can be compared with precision digital voltmeters to…

仪器与探测器 · 物理学 2019-07-24 O. Rest , D. Winzen , S. Bauer , R. Berendes , J. Meisner , T. Thümmler , S. Wüstling , C. Weinheimer

Pipelined analog-to-digital converters (ADCs) are fundamental components of various signal processing systems requiring high sampling rates and a high linearity. Over the past years, calibration techniques have been intensively investigated…

信号处理 · 电气工程与系统科学 2022-07-12 Matthias Wagner , Oliver Lang , Thomas Bauernfeind , Mario Huemer

This paper presents a joint calibration scheme for voltage (V) and current (I) probes that helps resolve accurately voltage-current phase differences even when the difference is very close to $90^{\circ}$. The latter has been a major issue…

等离子体物理 · 物理学 2022-12-27 Mahreen , A. Ganguli , Veda Prakash Gajula , Satyananda Kar , Debaprasad Sahu

Robot positioning accuracy is a key factory when performing high-precision manufacturing tasks. To effectively improve the accuracy of a manipulator, often up to a value close to its repeatability, calibration plays a crucial role. In the…

机器人学 · 计算机科学 2025-02-24 Giovanni Boschetti , Teresa Sinico

We describe a calibration setup for the transresistance of low-current amplifiers, based on the capacitance-charging method. The calibration can be performed in the current range of typical interest for electron counting experiments. The…

仪器与探测器 · 物理学 2016-10-18 Ilaria Finardi , Luca Callegaro

At National Institute of Metrological Research (INRIM), a selectable-value Transportable High dcVoltage Standard (THVS) operating in the range from 10 V to 100 V in steps of 10 V, was developed. This Standard was built to cover the lack of…

仪器与探测器 · 物理学 2016-05-17 Flavio Galliana , Roberto Cerri , Luca Roncaglione Tet

A single-contact voltage sensor designed for accurate measurements of ac voltages across a pair of conductors is described. The sensor design is motivated by remote monitoring applications where accurate voltage measurement of high-voltage…

仪器与探测器 · 物理学 2020-06-29 Jake S. Bobowski , Saimoom Ferdous , Thomas Johnson

Dynamic quantum circuits incorporate mid-circuit measurements and feed-forward operations originally intended to realize Quantum Error Correction. This paradigm has recently been utilized to prepare certain states and long-range entangling…

In the last decades, various events have shown that electromechanical oscillations are a major concern for large interconnected Alternative Current (AC) power systems. DC segmentation - a method that consist in turning large AC grids into a…

To test and calibrate various detectors in nuclear and high energy physics experiments, a general purposed calibration instrument has been developed. All information including timing, amplitude and charge of signals can be directly obtained…

仪器与探测器 · 物理学 2018-06-26 Zhe Cao , Jiadong Hu , Cheng Li , Shubin Liu , Qi An

Radiation detectors deployed as part of a large urban network or for homeland security monitoring must maintain reliable energy calibration even when subjected to substantial variations in temperature and ambient background radiation.…

Many parallel and distributed computing research results are obtained in simulation, using simulators that mimic real-world executions on some target system. Each such simulator is configured by picking values for parameters that define the…

分布式、并行与集群计算 · 计算机科学 2024-07-03 Jesse McDonald , Maximilian Horzela , Frédéric Suter , Henri Casanova
‹ 上一页 1 2 3 10 下一页 ›