We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle…

仪器与探测器 · 物理学 2015-06-09 Katsushige Kotera , Daniel Jeans , Akiya Miyamoto , Tohru Takeshita

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…

仪器与探测器 · 物理学 2014-07-24 CALICE Collaboration , K. Francis , J. Repond , J. Schlereth , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , G. Eigen , Y. Mikami , N. K. Watson , M. A. Thomson , D. R. Ward , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Dotti , G. Folger , V. Ivantchenko , A. Ribon , V. Uzhinskiy , C. Carloganu , P. Gay , S. Manen , L. Royer , M. Tytgat , N. Zaganidis , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , A. Ebrahimi , G. Falley , K. Gadow , P. Goettlicher , C. Guenter , O. Hartbrich , B. Hermberg , S. Karstensen , F. Krivan , K. Krueger , B. Lutz , S. Morozov , V. Morgunov , C. Neubueser , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , E. Garutti , S. Laurien , S. Lu , I. Marchesini , M. Matysek , M. Ramilli , K. Briggl , P. Eckert , T. Harion , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , G. W. Wilson , K. Kawagoe , Y. Sudo , T. Yoshioka , P. D. Dauncey , M. Wing , F. Salvatore , E. Cortina Gil , S. Mannai , G. Baulieu , P. Calabria , L. Caponetto , C. Combaret , R. Della Negra , G. Grenier , R. Han , J-C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeur , M. Vander Donckt , Y. Zoccarato , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , F. Corriveau , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Popov , V. Rusinov , E. Tarkovsky , D. Besson , P. Buzhan , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , V. Tikhomirov , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , M. S. Amjad , J. Bonis , S. Callier , S. Conforti di Lorenzo , P. Cornebise , Ph. Doublet , F. Dulucq , J. Fleury , T. Frisson , N. van der Kolk , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , J. Rouene , N. Seguin-Moreau , M. Anduze , V. Balagura , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , E. Guliyev , Y. Haddad , F. Magniette , G. Musat , M. Ruan , T. H. Tran , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , H. Ono , T. Takeshita , S. Uozumi , D. Jeans , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , M. Goetze , J. Sauer , S. Weber , C. Zeitnitz

The CALICE collaboration is developing a granular electromagnetic calorimeter using (5-10) mm x 45 mm x 3 mm scintillator strips for a future linear collider experiment. Each scintillator strip is read out by using a Pixelated Photon…

仪器与探测器 · 物理学 2012-02-01 Katsushige Kotera

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…

仪器与探测器 · 物理学 2012-08-08 C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , Y. Mikami , N. K. Watson T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward W. Yan , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , R. Fabbri , G. Falley , K. Gadow , E. Garutti , P. Göttlicher , C. Günter , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , I. Marchesini , N. Meyer , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Wattimena , O. Wendt , N. Feege , J. Haller , S. Richter , J. Samson P. Eckert , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , S. Uozumi , J. A. Ballin , P. D. Dauncey , A. -M. Magnan , H. S. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , V. Balagura , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Rusinov , E. Tarkovsky , Y. Soloviev , V. Kozlov , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , A. Frey , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , F. Dulucq , M. Faucci Giannelli , J. Fleury , G. Guilhem , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , M. Nishiyama , T. Takeshita , S. Tozuka , T. Buanes , G. Eigen

We report on the simulation results for the angular resolution of an electromagnetic (EM) sampling calorimeter with photons in the range of 100~MeV to 2~GeV. The simulation model of the EM calorimeter consists of alternating layers of a…

仪器与探测器 · 物理学 2023-04-26 Junlee Kim , Eun-Joo Kim , YoungJun Kim , JungKeun Ahn , GeiYoub Lim

A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten…

仪器与探测器 · 物理学 2009-10-06 R. McNabb , J. Blackburn , J. D. Crnkovic , D. W. Hertzog , B. Kiburg , J. Kunkle , E. Thorsland , D. M. Webber , K. R. Lynch

Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating…

仪器与探测器 · 物理学 2014-06-17 C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Schlereth , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , T. Buanes , G. Eigen , Y. Mikami , N. K. Watson , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Dotti , G. Folger , V. Ivantchenko , V. Uzhinskiy , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , G. Falley , K. Gadow , P. Göttlicher , C. Günter , B. Hermberg , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Feege , E. Garutti , I. Marchesinik , M. Ramilli , P. Eckert , T. Harion , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , P. D. Dauncey , A. -M. Magnan , V. Bartsch , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Popov , V. Rusinov , E. Tarkovsky , N. Kirikova , V. Kozlov , P. Smirnov , Y. Soloviev , P. Buzhan , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , V. Tikhomirov , C. Kiesling , K. Seidel , F. Simon , C. Soldner , M. Szalay , M. Tesar , L. Weuste , M. S. Amjad , J. Bonis , S. Callier , S. Conforti di Lorenzo , P. Cornebise , Ph. Doublet , F. Dulucq , J. Fleury , T. Frisson , N. van der Kolk , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , J. Rouëné , N. Seguin-Moreau , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , T. Takeshita , S. Uozumi , M. Götze , O. Hartbrich , J. Sauer , S. Weber , C. Zeitnitz

The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…

Precision physics at future multi-TeV lepton colliders such as CLIC requires excellent jet energy resolution. The detectors need deep calorimeter systems to limit the energy leakage also for very highly energetic particles and jets. At the…

仪器与探测器 · 物理学 2019-08-13 Frank Simon

The CALICE collaboration is developing highly granular electromagnetic and hadronic calorimeters for detectors at future energy frontier electron-positron colliders. After successful tests of a physics prototype, a technological prototype…

仪器与探测器 · 物理学 2022-10-03 CALICE Collaboration

We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…

We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton…

Next-generation high-energy electron-positron colliders, operating as Higgs factories, require an unprecedented jet energy resolution for precision measurements of Higgs and Z/W bosons. To address this challenge, a conceptual design is…

A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…

仪器与探测器 · 物理学 2010-07-16 Adil Khan

The CALICE collaboration is developing a granular electromagnetic calorimeter using small scintillator strips for a future linear collider experiment. On developing of ~ 10^7 channel-ECAL in particle flow approach, CALICE is developing a…

仪器与探测器 · 物理学 2014-04-08 Katsushige Kotera

In the context of developing a hadron calorimeter with extremely fine granularity for the application of Particle Flow Algorithms to the measurement of jet energies at a future lepton collider, we report on extensive tests of a small scale…

A high granularity hadronic 1 m3 calorimeter prototype with semi-digital readout has been designed and built. This calorimeter has been made using stainless steel as absorber and Glass Resistive Plates Chambers (GRPC) as active medium, and…

仪器与探测器 · 物理学 2019-08-13 M. C Fouz

Scintillator-based calorimeters for experiments at Higgs factories (e.g. ILC) demand scintillator designs that can detect sufficient number of photons and have good light yield uniformity, and that they can be easily mass-produced. In order…

A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at…

仪器与探测器 · 物理学 2019-08-13 Frank Simon

The original dual-readout calorimeter prototype (DREAM), constructed two decades ago, has proven instrumental in advancing our understanding of calorimetry. It has facilitated a multitude of breakthroughs by leveraging signals from…