中文
相关论文

相关论文: Dwell time modulation restrictions do not necessar…

200 篇论文

Conventional planning objectives in optimization of intensity-modulated radiotherapy treatment (IMRT) plans are designed to minimize the violation of dose-volume histogram (DVH) thresholds using penalty functions. Although successful in…

医学物理 · 物理学 2023-07-19 Lovisa Engberg , Kjell Eriksson , Anders Forsgren , Björn Hårdemark

High-dose-rate (HDR) brachytherapy plays a critical role in the treatment of locally advanced cervical cancer but remains highly dependent on manual treatment planning expertise. The objective of this study is to develop a fully automated…

Purpose: In high-dose-rate (HDR) prostate brachytherapy procedures, the pattern of needle placement solely relies on physician experience. We investigated the feasibility of using reinforcement learning (RL) to provide needle positions and…

医学物理 · 物理学 2025-06-12 Tonghe Wang , Yining Feng , Xiaofeng Yang

Purpose: To determine whether alternative HDR prostate brachytherapy catheter patterns can result in improved dose distributions while providing better access and reducing trauma. Methods: Prostate HDR brachytherapy uses a grid of parallel…

医学物理 · 物理学 2015-05-13 J. Adam M. Cunha , I-Chow Hsu , Jean Pouliot

High dose-rate brachytherapy (HDRBT) is widely used for gynecological cancer treatment. Although commercial treatment planning systems (TPSs) have inverse optimization modules, it takes several iterations to adjust planning objectives to…

医学物理 · 物理学 2021-09-14 Huan Liu , Chang M Ma , Xun Jia , Chenyang Shen , Peter Klages , Kevin Albuquerque

High-dose-rate brachytherapy is a tumor treatment method where a highly radioactive source is brought in close proximity to the tumor. In this paper we develop a simulated annealing algorithm to optimize the dwell times at preselected dwell…

医学物理 · 物理学 2017-03-29 Timo M. Deist , Bram L. Gorissen

Purpose: Many planning methods for high dose rate (HDR) brachytherapy treatment planning require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose…

医学物理 · 物理学 2016-11-25 Timmy Siauw , Adam Cunha , Alper Atamturk , I-Chow Hsu , Jean Pouliot , Ken Goldberg

This work aims to study the generalizability of a pre-developed deep learning (DL) dose prediction model for volumetric modulated arc therapy (VMAT) for prostate cancer and to adapt the model to three different internal treatment planning…

Traditional VMAT optimization often ignores dynamic machine limits, treating delivery time as an emergent property rather than a steerable parameter. This work introduces Dynamic Modulated Arc Therapy (DMAT), an intent-driven framework that…

This study presents the development and validation of an independent software tool based on the Varian Eclipse Scripting API (ESAPI) for multi-modal brachytherapy Quality Assurance (QA). The tool addresses GEC-ESTRO HDR protocols and LDR…

医学物理 · 物理学 2026-03-24 J. A. Valgoma

Interfractional geometric uncertainties can lead to deviations of the actual delivered dose from the prescribed dose distribution. To better handle these uncertainties during treatment, the authors propose a dynamic framework for robust…

医学物理 · 物理学 2019-05-16 Michelle Böck , Kjell Eriksson , Anders Forsgren

The development of a digital twin (DT) framework for fast online adaptive proton therapy planning in prostate stereotactic body radiation therapy (SBRT) with dominant intraprostatic lesion (DIL) boost represents a significant advancement in…

To accurately verify the dose of intensity-modulated radiation therapy (IMRT), we have used a global optimization method to investigate a new dose-verification algorithm. In practical application of this quality assurance (QA) procedure,…

We present a method of directly optimizing on deviations in clinical goal values in radiation therapy treatment planning. Using a new mathematical framework in which metrics derived from the dose-volume histogram are regarded as functionals…

医学物理 · 物理学 2021-09-07 Tianfang Zhang , Rasmus Bokrantz , Jimmy Olsson

Sequential multiple assignment randomized trials (SMARTs) provide a systematic framework for constructing and evaluating dynamic treatment regimens (DTRs). In clinical studies, longitudinal biomarkers are routinely collected to monitor…

统计方法学 · 统计学 2026-05-06 Zhengxi Chen , Holly Hartman

Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core…

Purpose: We introduce a novel concept of a compact multiprobe scintillator detector and demonstrate its applicability in HDR-brachytherapy. Our fabricated seven-probe system is sufficiently narrow to be inserted in a brachytherapy needle or…

Purpose: To investigate the impact of delivery techniques and planning parameters on interplay effect in lung SBRT. Methods: A dynamic virtual patient model containing normal structures and a tumor with adjustable sizes, locations, and 3D…

We develop and evaluate tolerance interval methods for dynamic treatment regimes (DTRs) that can provide more detailed prognostic information to patients who will follow an estimated optimal regime. Although the problem of constructing…

统计方法学 · 统计学 2017-04-26 Daniel J. Lizotte , Arezoo Tahmasebi

Anatomical changes during intensity-modulated proton therapy (IMPT) for head-and-neck cancer (HNC) can shift Bragg peaks, risking tumor underdosing and organ-at-risk overdosing. Treatment replanning is often required to maintain clinically…

医学物理 · 物理学 2025-08-13 Malvern Madondo , Yuan Shao , Yingzi Liu , Jun Zhou , Xiaofeng Yang , Zhen Tian
‹ 上一页 1 2 3 10 下一页 ›