中文
相关论文

相关论文: Status of the DAMIC direct dark matter search expe…

200 篇论文

The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to…

The DAMIC (Dark Matter in CCDs) experiment at the SNOLAB underground laboratory uses fully depleted, high resistivity CCDs to search for dark matter particles with masses below 10 GeV/c$^2$. An upgrade of the detector using an array of…

天体物理仪器与方法 · 物理学 2018-07-01 Mariangela Settimo

DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique sensitivity to dark matter particles with masses below 10 GeV. Due to its low electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a detection…

The DAMIC (Dark Matter in CCDs) experiment searches for the interactions of dark matter particles with the nuclei and the electrons in the silicon bulk of thick fully depleted charge-coupled devices (CCDs). Because of the low noise and low…

高能物理 - 实验 · 物理学 2020-04-02 Mariangela Settimo

Experimental efforts of the last decades have been unsuccessful in detecting WIMPs (Weakly Interacting Massive Particles) in the 10-to-10$^4$ GeV/$c^2$ range, thus motivating the search for lighter dark matter. The DAMIC (DArk Matter In…

宇宙学与河外天体物理 · 物理学 2021-10-05 Michelangelo Traina

This report presents an overview of the unconventional use of charge-coupled devices (CCDs) to search for Dark Matter (DM). The DArk Matter In CCDs (DAMIC Experiment) employs the bulk silicon of thick, fully-depleted CCDs as a target for…

仪器与探测器 · 物理学 2020-01-14 N. Castello-Mor , DAMIC-M Collaboration

The DAMIC experiment employs large-area, thick charge-coupled devices (CCDs) to search for the interactions of low-mass dark matter particles in the galactic halo with silicon atoms in the CCD target. From 2017 to 2019, DAMIC collected data…

宇宙学与河外天体物理 · 物理学 2022-10-04 Alvaro E. Chavarria

We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices…

Dark Matter In CCDs (DAMIC) is a silicon detector apparatus used primarily for searching for low-mass dark matter using the silicon bulk of Charge-Coupled Devices (CCDs) as targets. The silicon target within each CCD is…

仪器与探测器 · 物理学 2020-03-09 Steven Juhyung Lee , Ben Kilminster , Anna Macchiolo

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…

The DAMIC-M (DArk Matter In CCDs at Modane) experiment will use skipper CCDs to search for low mass (sub-GeV) dark matter underground at the Laboratoire Souterrain de Modane (LSM) in France. With about 1 kg of silicon target mass and…

高能物理 - 实验 · 物理学 2024-10-01 R. Smida

We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed…

A direct dark matter search is performed using fully-depleted high-resistivity CCD detectors . Due to their low electronic readout noise (RMS ~ 7 eV) these devices operate with a very low detection threshold of 40 eV, making the search for…

天体物理仪器与方法 · 物理学 2015-05-28 J. Barreto , H. Cease , H. T. Diehl , J. Estrada , B. Flaugher , N. Harrison , J. Jones , B. Kilminster , J. Molina , J. Smith , T. Schwarz , A. Sonnenschein

The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at low pressure (0.1 atm) to search for the directional signature of Galactic WIMP dark matter. We describe the DMTPC apparatus and summarize recent results from a…

The report describes the research program on the development of ultra-low-energy germanium detectors, with emphasis on WIMP dark matter searches. A threshold of 100 eV is achieved with a 20 g detector array, providing a unique probe to the…

高能物理 - 实验 · 物理学 2008-11-26 H. T. Wong

The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run…

宇宙学与河外天体物理 · 物理学 2018-01-24 SuperCDMS Collaboration , R. Agnese , A. J. Anderson , T. Aralis , T. Aramaki , I. J. Arnquist , W. Baker , D. Balakishiyeva , D. Barker , R. Basu Thakur , D. A. Bauer , T. Binder , M. A. Bowles , P. L. Brink , R. Bunker , B. Cabrera , D. O. Caldwell , R. Calkins , C. Cartaro , D. G. Cerdeno , Y. Chang , H. Chagani , Y. Chen , J. Cooley , B. Cornell , P. Cushman , M. Daal , P. C. F. Di Stefano , T. Doughty , L. Esteban , E. Fascione , E. Figueroa-Feliciano , M. Fritts , G. Gerbier , M. Ghaith , G. L. Godfrey , S. R. Golwala , J. Hall , H. R. Harris , Z. Hong , E. W. Hoppe , L. Hsu , M. E. Huber , V. Iyer , D. Jardin , A. Jastram , C. Jena , M. H. Kelsey , A. Kennedy , A. Kubik , N. A. Kurinsky , A. Leder , B. Loer , E. Lopez Asamar , P. Lukens , D. MacDonell , R. Mahapatra , V. Mandic , N. Mast , E. H. Miller , N. Mirabolfathi , R. A. Moffatt , B. Mohanty , J. D. Morales Mendoza , J. Nelson , J. L. Orrell , S. M. Oser , K. Page , W. A. Page , R. Partridge , M. Pepin , M. Penalver Martinez , A. Phipps , S. Poudel , M. Pyle , H. Qiu , W. Rau , P. Redl , A. Reisetter , T. Reynolds , A. Roberts , A. E. Robinson , H. E. Rogers , T. Saab , B. Sadoulet , J. Sander , K. Schneck , R. W. Schnee , S. Scorza , K. Senapati , B. Serfass , D. Speller , M. Stein , J. Street , H. A. Tanaka , D. Toback , R. Underwood , A. N. Villano , B. von Krosigk , B. Welliver , J. S. Wilson , M. J Wilson , D. H. Wright , S. Yellin , J. J. Yen , B. A. Young , X. Zhang , X. Zhao

The possibility of using CCD detectors in a low threshold direct detection dark matter search experiment is discussed. We present the main features of the DECam detectors that make them a good alternative for such an experiment, namely…

高能物理 - 实验 · 物理学 2008-07-01 J. Estrada , H. Cease , H. T. Diehl , B. Flaugher , J. Jones , D. Kubik , A. Sonnenschein

The Cryogenic Dark Matter search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering of target nuclei. The last analysis with an germanium exposure of 397.8 kg-days resulted in zero…

天体物理仪器与方法 · 物理学 2019-08-13 T. Bruch
‹ 上一页 1 2 3 10 下一页 ›