A versatile and portable magnetically shielded room with a field of (700 \pm 200) pT within a central volume of 1m x 1m x 1m and a field gradient less than 300 pT/m is described. This performance represents more than a hundred-fold…

A passive magnetic shield was designed and constructed for magnetometer tests for the future neutron electric dipole moment experiment at TRIUMF. The axial shielding factor of the magnetic shield was measured using a magnetometer based on…

Here, a benchtop hybrid magnetic shield containing four mumetal cylinders and nine internal flexible printed circuit boards is designed, constructed, tested, and operated. The shield is designed specifically as a test-bed for building and…

High-permeability magnetic shields generate magnetic field noise that can limit the sensitivity of modern precision measurements. We show that calculations based on the fluctuation-dissipation theorem allow quantitative evaluation of…

仪器与探测器 · 物理学 2009-11-13 S. -K. Lee , M. V. Romalis

We propose a resonant electromagnetic detector to search for hidden-photon dark matter over an extensive range of masses. Hidden-photon dark matter can be described as a weakly coupled "hidden electric field," oscillating at a frequency…

高能物理 - 唯象学 · 物理学 2015-10-14 Saptarshi Chaudhuri , Peter W. Graham , Kent Irwin , Jeremy Mardon , Surjeet Rajendran , Yue Zhao

Mechanical resonances are used in a wide variety of devices; from smart phone accelerometers to computer clocks and from wireless communication filters to atomic force microscope sensors. Frequency stability, a critical performance metric,…

An experimental strong increase of the reflection loss (from 25 up to 35 dBs) and an extension of the absorption bandwidth up to 20% is measured in a set of novel functional bilayer systems. We focus our work on studying the samples in an…

Magnetically-sensitive experiments and newly-developed quantum technologies with integrated high-permeability magnetic shields require increasing control of their magnetic field environment and reductions in size, weight, power and cost.…

We explored vibrations of a single-degree of freedom oscillator with a magneto-rheological damper subjected to kinematic excitations. Using fast and slow scales decoupling procedure we derived an effective damping coefficient in the limit…

混沌动力学 · 物理学 2007-05-23 Marek Borowiec , Grzegorz Litak , Rafal Kasperek

We report on optomechanical GaAs disk resonators with ultrahigh quality factor - frequency product Qf. Disks standing on a simple pedestal exhibit GHz breathing modes attaining a Qf of 10^13 measured under vacuum at cryogenic temperature.…

An increasing number of measurements in fundamental and applied physics rely on magnetically shielded environments with sub nano-Tesla residual magnetic fields. State of the art magnetically shielded rooms (MSRs) consist of up to seven…

The effect of passive magnetic shielding on dc magnetic field gradients imposed by both external and internal sources is studied. It is found that for concentric cylindrical or spherical shells of high permeability material, higher order…

仪器与探测器 · 物理学 2013-10-31 C. P. Bidinosti , J. W. Martin

Metglas 2705M is a low-cost commercially-available, high-permeability Cobalt-based magnetic alloy, provided as a 5.08-cm wide and 20.3-$\mu$m thick ribbon foil. We present an optimized construction technique for single-shell, large-scale…

原子物理 · 物理学 2011-07-14 S. Malkowski , R. Adhikari , B. Hona , C. Mattie , D. Woods , H. Yan , B. Plaster

State-of-the-art magnetic field measurements performed in shielded environments with carefully controlled conditions rarely reflect the realities of those applications envisioned in the introductions of peer-reviewed publications.…

原子物理 · 物理学 2020-10-13 Kai-Mei C. Fu , Geoffrey Z. Iwata , Arne Wickenbrock , Dmitry Budker

We report on the design, construction, and performance of a compact magnetic shield that facilitates a controlled, low-noise environment for experiments with ultracold atomic gases. The shield was designed to passively attenuate external…

Some of the most important technological challenges of today's society, such as fusion reactors for future clean unlimited energy or the next generation of medical imaging techniques, require precise spatial shapes of strong magnetic…

应用物理 · 物理学 2021-10-22 Alvaro Sanchez , Natanael Bort-Soldevila

Ferrite materials provide magnetic shielding performance similar to commonly used high permeability metals but have lower intrinsic magnetic noise generated by thermal Johnson currents due to their high electrical resistivity. Measurements…

原子物理 · 物理学 2007-07-26 T. W. Kornack , S. J. Smullin , S. -K. Lee , M. V. Romalis

Under negative feedback, the quality factor Q of a radio-frequency magnetometer can be decreased by more than two orders of magnitude, so that any initial perturbation of the polarized spin system can be rapidly damped, preparing the…

原子物理 · 物理学 2015-06-05 Orang Alem , Karen L. Sauer , Mike V. Romalis

We have experimentally studied the magnetic shielding properties of a cylindrical shell of BiPbSrCaCuO subjected to low frequency AC axial magnetic fields. The magnetic response has been investigated as a function of the dimensions of the…

In this paper a novel compressor for static magnetic fields is proposed based on finite embedded transformation optics. When the DC magnetic field passes through the designed device, the magnetic field can be compressed inside the device.…

经典物理 · 物理学 2013-09-25 F. Sun , S. He