中文
相关论文

相关论文: Improved Scatter Correction in X-Ray Cone Beam CT …

200 篇论文

In the scatter correction for x-ray Cone Beam (CB) CT, the single-scan scheme with moving Beam Stop Array (BSA) offers reliable scatter measurement with low dose, and by using Projection Correlation based View Interpolation (PC-VI), the…

医学物理 · 物理学 2014-11-03 Hao Yan , Xuanqin Mou , Yanbo Zhang , Maria Zankl

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

医学物理 · 物理学 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

医学物理 · 物理学 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed…

医学物理 · 物理学 2015-01-20 Wei Zhao , Jun Zhu , Luyao Wang

Cone-beam computed tomography (CBCT) has been widely used in medical imaging and industrial nondestructive testing, but the presence of scattered radiation will cause significant reduction of image quality. In this article, a robust scatter…

医学物理 · 物理学 2016-08-03 Kuidong Huang , Zhe Xu , Dinghua Zhang , Hua Zhang , Wenlong Shi

Cone-beam CT (CBCT) employs a flat-panel detector to achieve three-dimensional imaging with high spatial resolution. However, CBCT is susceptible to scatter during data acquisition, which introduces CT value bias and reduced tissue contrast…

计算机视觉与模式识别 · 计算机科学 2025-10-29 Xu Jiang , Huiying Pan , Ligen Shi , Jianing Sun , Wenfeng Xu , Xing Zhao

Due to its wide field of view, cone-beam computed tomography (CBCT) is plagued by large amounts of scatter, where attenuated photons hit the detector, and corrupt the linear models used for reconstruction. Given that one can generate a good…

医学物理 · 物理学 2017-07-06 Jonathan Mason , Alessandro Perelli , William Nailon , Mike Davies

In Cone-Beam CT (CBCT) imaging systems, the scattering phenomenon has a significant impact on the reconstructed image and is a long-lasting research topic on CBCT. In this paper, we propose a simple, novel and fast approach for mitigating…

医学物理 · 物理学 2016-04-07 Shi-peng Xie , Rui-ju Yan

Scatter due to interaction of photons with the imaged object is a fundamental problem in X-ray Computed Tomography (CT). It manifests as various artifacts in the reconstruction, making its abatement or correction critical for image quality.…

医学物理 · 物理学 2024-01-30 Berk Iskender , Yoram Bresler

In this work, we compare one-step and two-step approaches for X-ray computed tomography (CT) scatter correction and density reconstruction. X-ray CT is an important imaging technique in medical and industrial applications. In many cases,…

图像与视频处理 · 电气工程与系统科学 2023-01-11 Alexander N. Sietsema , Michael T. McCann , Marc L. Klasky , Saiprasad Ravishankar

CBCT images suffer from acute shading artifacts primarily due to scatter. Numerous image-domain correction algorithms have been proposed in the literature that use patient-specific planning CT images to estimate shading contributions in…

计算机视觉与模式识别 · 计算机科学 2018-01-18 Awais Ashfaq , Jonas Adler

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…

图像与视频处理 · 电气工程与系统科学 2022-02-01 Ammar Alsaffar , Steffen Kieß , Kaicong Sun , Sven Simon

Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We…

医学物理 · 物理学 2016-10-18 Steven Tilley , Wojciech Zbijewski , Jeffrey H. Siewerdsen , J. Webster Stayman

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

信号处理 · 电气工程与系统科学 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

X-ray scatter remains a major physics challenge in volumetric computed tomography (CT), whose physical and statistical behaviors have been commonly leveraged in order to eliminate its impact on CT image quality. In this work, we conduct an…

医学物理 · 物理学 2021-03-05 Tao Zhang , Zhiqiang Chen , Hao Zhou , N. Robert Bennett , Adam S. Wang , Hewei Gao

X-ray scatter has been a serious concern in computed tomography (CT), leading to image artifacts and distortion of CT values. The linear Boltzmann transport equation (LBTE) is recognized as a fast and accurate approach for scatter…

医学物理 · 物理学 2025-08-29 Guoxi Zhu , Li Zhang , Zhiqiang Chen , Hewei Gao

Objective: The aim of this study is to validate the effectiveness of an energy-modulated scatter correction method in suppressing scatter in photon-counting detector (PCD)-based cone beam CT (CBCT) imaging. Approach: The scatter correction…

医学物理 · 物理学 2024-12-18 Xin Zhang , Ting Su , Jiongtao Zhu , Hairong Zheng , Dong Liang , Yongshuai Ge

Cone-beam computed tomography (CBCT) systems, with their flexibility, present a promising avenue for direct point-of-care medical imaging, particularly in critical scenarios such as acute stroke assessment. However, the integration of CBCT…

Recently, spectral CT has been drawing a lot of attention in a variety of clinical applications primarily due to its capability of providing quantitative information about material properties. The quantitative integrity of the reconstructed…

医学物理 · 物理学 2018-01-12 Shiyu Xu , Peter Prinsen , Jens Wiegert , Ravindra Manjeshwar

We propose a new modeling approach for scatter estimation and descattering in polyenergetic X-ray computed tomography (CT) based on fitting models to local neighborhoods of a training set. X-ray CT is widely used in medical and industrial…

图像与视频处理 · 电气工程与系统科学 2021-09-30 Michael T. McCann , Marc L. Klasky , Jennifer L. Schei , Saiprasad Ravishankar
‹ 上一页 1 2 3 10 下一页 ›