相关论文: A semi-empirical response function for Gamma-ray o…
In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the…
A novel design for an inexpensive depth of interaction capable detector for gamma rays, suitable for nuclear medical applications, especially Positron Emission Tomography, has been developed. The design takes advantage of the strong…
An approximation of the real line shape of a scintillation detector with a generalized gamma distribution is proposed. The approximation describes the ideal scintillation line shape better than the conventional normal distribution. Two…
This paper, presents a simple method for accurate calibration of organic scintillation detectors. The method is based on the fact that differentiating the response function leads to accurate estimation of the Compton edge. The…
To calculate static response properties of a many body system, local density approximation (LDA) can be safely applied. But applicability of LDA is limited for the case of dynamical response functions since dynamics of the system needs to…
Gamma sources are routinely used to calibrate the energy scale and resolution of liquid scintillator detectors. However, non-scintillating material surrounding the source introduces energy losses, which may bias the determination of the…
Liquid scintillator detectors are playing an increasingly important role in low-energy neutrino experiments. In this article, we describe a generic energy response model of liquid scintillator detectors that provides energy estimations of…
Scintillator detectors electronics is recalibrated against the datasheet given by the manufacturer. Optimal and mutual dependent values of (a) high voltage at PMT (Photomultiplier Tube), (b) amplifier gain, (c) average time to count the…
A novel data-processing method was developed to facilitate scintillation detector characterization. Combined with fan-beam calibration, this method can be used to quickly and conveniently calibrate gamma-ray detectors for SPECT, PET,…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…
The full instrument response of a superminiaturised CsI(Tl)-PiN photodiode radioactivity detector, intended for deployment on a meteorological radiosonde, has been modelled by combining a physics-based model of the sensor with the detector…
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up…
Properties of response functions of room temperature gamma-radiation detectors based on wide band-gap semiconductors are researched using Monte-Carlo method. It is shown that approximate formulas which connect detector sensitivity with…
Scintillator detector response modelling has become an essential tool in various research fields such as particle and nuclear physics, astronomy or geophysics. Yet, due to the system complexity and the requirement for accurate electron…
The Gamma-Ray Energy Tracking Array (GRETA) is a next-generation gamma-ray spectrometer designed to push the frontiers of nuclear structure and astrophysics experiment. Its high sensitivity is enabled by high-precision localization of…
The atmospheric response for MeV gamma rays (~ 0.1 - 10 MeV) can be characterized in terms of two observed components. The first component is due to photons that reach the detector without scattering. The second component is due to photons…
A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising…
Accurate estimates of Instrument Spectral Response Functions (ISRFs) are crucial in order to have a good characterization of high resolution spectrometers. Spectrometers are composed of different optical elements that can induce errors in…
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency.…
We propose a new scintillation-type detector in which high-energy radiation produces electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The…