相关论文: Monte Carlo simulation of MLC-shaped TrueBeam elec…
Monte Carlo (MC) simulation of linacs depends on the accurate geometrical description of the head. The geometry of the Varian TrueBeam (TB) linac is not available to researchers. Instead, the company distributes phase-space files (PSFs) of…
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription…
Purpose/Objective: Backscattered radiation (BSR) into linac monitor chamber has to be accounted for in radiotherapy dose calculations. In Monte Carlo (MC) calculations, the BSR can be modeled explicitly, but only when treatment head…
Flattening filter free (FFF) beams due to their non-uniformity, are sub-optimal for larger field sizes. The purpose of this study was to investigate the incident electron beam distributions that would produce flat FFF beams without the use…
Adaptive Radiation Therapy (ART) was developed based on Image-guided Radiation Therapy (IGRT) and it is the trend of photon radiation therapy. To get a better use of Cone Beam CT (CBCT) images for ART, the CBCT system model was established…
Purpose: To investigate the validity of two Monte Carlo simulation absolute dosimetry approaches in the case of a small field dedicated `D'-shaped collimator used for the retinoblastoma treatment with external photon beam radiotherapy.…
The present work is devoted to develop a computational model using the Gate Monte Carlo software for the simulation of a 6MV photon beam given by Elekta Synergy Platform medical linear accelerator treatment head. The model includes the…
Objective: To develop and validate an independent Monet Carlo dose calculation engine to support for software verification of treatment planning systems and quality assurance workflow. Method: GATE Monte Carlo toolkit was employed to…
Accurate proton dose calculation using Monte Carlo (MC) is computationally demanding in workflows like robust optimisation, adaptive replanning, and probabilistic inference, which require repeated evaluations. To address this, we develop a…
To develop a machine learning-based framework for accurately modeling the anode heel effect in Monte Carlo simulations of X-ray imaging systems, enabling realistic beam intensity profiles with minimal experimental calibration. Multiple…
A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil…
During the past years several variance reduction techniques for Monte Carlo electron transport have been developed in order to reduce the electron computation time transport for absorbed dose distribution. We have implemented the Macro…
Objective: Research on eye lens dosimetry for radiation workers has increased after the 2012 ICRP118 update on eye lens dose limits. However, corneal dosimetry remains underexplored due to historical focus and measurement challenges. This…
Purpose: A Monte Carlo (MC) beam model and its implementation in a clinical treatment planning system (TPS, Varian Eclipse) are presented for a modified ultra-high dose-rate electron FLASH radiotherapy (eFLASH-RT) LINAC. Methods: The gantry…
Monte Carlo (MC) simulation is considered as the most accurate method for radiation dose calculations. Accuracy of a source model for a linear accelerator is critical for the overall dose calculation accuracy. In this paper, we presented an…
A high-fidelity kinetic Monte Carlo (KMC) simulation method (T. Treeratanaphitak, M. Pritzker, N. M. Abukhdeir, Electrochim. Acta 121 (2014) 407--414) using the semi-empirical multi-body embedded-atom method (EAM) potential has been…
Plasma simulations are powerful tools for understanding fundamental plasma science phenomena and for process optimization in applications. To ensure their quantitative accuracy, they must be validated against experiments. In this work, such…
For many complex simulation tasks spanning areas such as healthcare, engineering, and finance, Monte Carlo (MC) methods are invaluable due to their unbiased estimates and precise error quantification. Nevertheless, Monte Carlo simulations…
New collimators are being produced at CERN in the framework of a large particle accelerator upgrade project to protect beam lines against stray particles. Their movable jaws hold low density absorbers with tight geometric requirements,…
This study develops and validates a patient-specific Monte Carlo (MC) dosimetry framework for propagation-based phase-contrast breast CT (BCT) at the Imaging and Medical Beamline (IMBL), ANSTO Australian Synchrotron, for accurate mean…