相关论文: An improved model of Charge Transfer Inefficiency …
Charge Transfer Inefficiency (CTI) due to radiation damage above the Earth's atmosphere creates spurious trailing in Hubble Space Telescope (HST) images. Radiation damage also creates unrelated warm pixels - but these happen to be perfect…
Radiation damage to space-based Charge-Coupled Device (CCD) detectors creates defects which result in an increasing Charge Transfer Inefficiency (CTI) that causes spurious image trailing. Most of the trailing can be corrected during…
We update a physically-motivated model of radiation damage in the Hubble Space Telescope Advanced Camera for Surveys/Wide Field Channel, using data up to mid 2010. We find that Charge Transfer Inefficiency increased dramatically before…
From 2002 to 2025, the Hubble Space Telescope's Advanced Camera for Surveys has suffered in the harsh radiation environment above the protection of the Earth's atmosphere. We track the degradation of its image quality, as Solar protons and…
The ACIS front-illuminated CCDs onboard the Chandra X-ray Observatory were damaged in the extreme environment of the Earth's radiation belts, resulting in enhanced charge transfer inefficiency (CTI). This produces a row dependence in gain,…
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…
A variety of on-orbit imaging and spectroscopic observations are used to characterize the Charge Transfer Efficiency (CTE) of the Charge-Coupled Device (CCD) of the Space Telescope Imaging Spectrograph (STIS) aboard the Hubble Space…
The traditional characterization of charge transfer inefficiency (CTI) in charge-coupled devices (CCDs) can suffer from a number of deficiencies: CTI is often only calculated for a limited number of signal levels, CTI is calculated from a…
We use an empirical approach to characterize the effect of charge-transfer efficiency (CTE) losses in images taken with the Wide-Field Channel of the Advanced Camera for Surveys. The study is based on profiles of warm pixels in 168 dark…
The front-illuminated (FI) CCDs in the Advanced CCD Imaging Spectrometer (ACIS) on the Chandra X-ray Observatory (Chandra) were damaged in the extreme environment of the Earth's radiation belts, causing charge traps that result in enhanced…
(Abridged) We examine the effects of charge transfer inefficiency (CTI) during CCD readout on galaxy shape measurements required by studies of weak gravitational lensing. We simulate a CCD readout with CTI such as that caused by charged…
We present experimental studies on the charge transfer inefficiency (CTI) of charge-coupled device (CCD) developed for the soft X-ray imaging telescope, Xtend, aboard the XRISM satellite. The CCD is equipped with a charge injection (CI)…
PLATO is designed to detect Earth-sized exoplanets around solar-type stars and to measure their radii with accuracy better than \(2\%\) via the transit method. Charge transfer inefficiency (CTI), a by-product of radiation damage to CCDs,…
Current optical space telescopes rely upon silicon Charge Coupled Devices (CCDs) to detect and image the incoming photons. The performance of a CCD detector depends on its ability to transfer electrons through the silicon efficiently, so…
Most discussion of charge-transfer-efficiency (CTE) losses involves the parallel transfer of charge in the y-direction down the chip columns (y-CTE). Serial charge-transfer efficiency (x-CTE) refers to the horizontal transer of charge.…
Using repeat imaging of a galaxy cluster taken over a seventeen-year baseline, we examine the impact that degraded Charge Transfer Efficiency (CTE) has on photometric measurements of extended sources using the ACS/WFC on HST. We examine how…
Soon after launch, the Advanced CCD Imaging Spectrometer (ACIS), one of the focal plane instruments on the Chandra X-ray Observatory, suffered radiation damage from exposure to soft protons during passages through the Earth's radiation…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
The STECF Calibration Enhancement effort for the Space Telescope Imaging Spectrograph (STIS) aims to improve data calibration via the application of physical modelling techniques. As part of this effort we have developed a model of the STIS…
Charge Coupled Devices (CCDs) have been successfully used in several low energy X-ray astronomical satellite over the past two decades. Their high energy resolution and high spatial resolution make them an perfect tool for low energy…