中文
相关论文

相关论文: Long-term operation of a double phase LAr LEM Time…

200 篇论文

This paper describes the design, realization and operation of a prototype liquid Argon Time Projection Chamber (LAr TPC) detector dedicated to the development of a novel online monitoring and calibration system exploiting UV laser beams. In…

The dynamics of the positive ions created by particle interactions inside argon time projection chambers plays an important role in characterizing the next generation of massive detectors planned for the direct search for dark matter and…

For the future neutrino oscillation experiment DUNE, liquid argon time projections chambers with a fiducial mass of 10 kton each are foreseen. The dual phase concept is one of the two implementations considered, wherein electrons produced…

仪器与探测器 · 物理学 2019-05-22 T. Lux

After the Long Shutdown 2 the LHC will provide lead-lead collisions at interaction rates as high as 50kz. In order to cope with such conditions the ALICE Time Projection Chamber (TPC) needs to be upgraded. After the upgrade the TPC will run…

仪器与探测器 · 物理学 2019-08-12 Alexander Deisting

Gated wires are widely used in Time Projection Chamber (TPC) to avoid ion back-flow (IBF) in the drift volume. The anode wires can provide stable gain at high voltage with a long lifetime. However, switching on and off the gated grid (GG)…

仪器与探测器 · 物理学 2019-07-24 Shuai Wang , Fuwang Shen , Xiao Zhao , Zhihang Zhu , Fangang Kong , Changyu Li , Qinghua Xu , Zhangbu Xu , Chi Yang , Chengguang Zhu

A large Time Projection Chamber (TPC) is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019-2020, the LHC will deliver Pb beams colliding at an…

仪器与探测器 · 物理学 2019-10-09 Piotr Gasik

The ICARUS T600 detector, the largest liquid Argon Time Projection Chamber (LAr-TPC) realized after many years of RD activities, was installed and successfully operated for 3 years at the INFN Gran Sasso underground Laboratory. One of the…

The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction…

仪器与探测器 · 物理学 2023-02-17 MicroBooNE collaboration , R. Acciarri , C. Adams , R. An , J. Anthony , J. Asaadi , M. Auger , L. Bagby , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , M. Bishai , A. Blake , T. Bolton , B. Bullard , L. Camilleri , D. Caratelli , B. Carls , R. Castillo Fernandez , F. Cavanna , H. Chen , E. Church , D. Cianci , E. Cohen , G. H. Collin , J. M. Conrad , M. Convery , J. I. Crespo-Anadon , G. De Geronimo , M. Del Tutto , D. Devitt , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , A. A. Fadeeva , B. T. Fleming , W. Foreman , A. P. Furmanski , D. Garcia-Gamez , G. T. Garvey , V. Genty , D. Goeldi , S. Gollapinni , N. Graf , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , J. Ho , G. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , C. -M. Jen , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , D. Kaleko , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , A. Laube , S. Li , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , C. Mariani , J. Marshall , D. A. Martinez Caicedo , V. Meddage , T. Miceli , G. B. Mills , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Paolone , V. Papavassiliou , S. F. Pate , Z. Pavlovic , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , S. Rescia , L. Rochester , C. Rudolf von Rohr , B. Russell , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , A. M. Szelc , N. Tagg , K. Terao , M. Thomson , C. Thorn , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , D. A. Wickremasinghe , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , L. Yates , B. Yu , G. P. Zeller , J. Zennamo , C. Zhang

The MicroBooNE experiment at Fermilab uses liquid argon time projection chamber (LArTPC) technology to study neutrino interactions in argon. A fundamental requirement for LArTPCs is to achieve and maintain a low level of electronegative…

仪器与探测器 · 物理学 2017-10-03 Varuna Meddage

A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle…

For the International Large Detector concept at the planned International Linear Collider, the use of time projection chambers (TPC) with micro-pattern gas detector readout as the main tracking detector is investigated. In this paper,…

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

The Time Projection Chamber (TPC) is an ideal candidate to finely study the charged particle ionization in a gaseous medium. Large volumes TPCs can be read out with a suitable number of channels offering a complete 3D reconstruction of an…

A fundamental limit to the application of Time Projection Chambers (TPCs) in high-rate experiments is the accumulation of slowly drifting ions in the active gas volume, which compromises the homogeneity of the drift field and hence the…

仪器与探测器 · 物理学 2012-09-05 F. V. Böhmer , M. Ball , S. Dørheim , C. Höppner , B. Ketzer , I. Konorov , S. Neubert , S. Paul , J. Rauch , M. Vandenbroucke

ARIADNE is a 1-ton (330 kg fiducial mass) dual-phase liquid argon (LAr) time projection chamber (TPC) featuring a novel optical readout. Four electron-multiplying charge-coupled device (EMCCD) cameras are mounted externally, and these…

A Time Projection Chamber (TPC) is an ideal device for the detection of charged particle tracks in a large volume covering a solid angle of almost $4\pi$. The high density of hits on a given particle track facilitates the task of pattern…

A key feature for the success of the liquid Argon imaging TPC (LAr-TPC) technology is the industrial purification against electro-negative impurities, especially Oxygen and Nitrogen remnants, which have to be continuously kept at an…

We present the results of the first exposure of a Liquid Argon TPC to a multi-GeV neutrino beam. The data have been collected with a 50 liters ICARUS-like chamber located between the CHORUS and NOMAD experiments at the CERN West Area…

仪器与探测器 · 物理学 2008-11-26 F. Arneodo et al.

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events.…