中文
相关论文

相关论文: Time resolution below 100 ps for the SciTil detect…

200 篇论文

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy,…

医学物理 · 物理学 2012-03-02 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

A new high-granular compact time-of-flight neutron detector for the identification and energy measurement of neutrons produced in nucleus-nucleus interactions at the BM@N experiment, Dubna, Russia, at energies up to 4 AGeV is under…

仪器与探测器 · 物理学 2024-08-19 N. Karpushkin , D. Finogeev , F. Guber , D. Lyapin , A. Makhnev , S. Morozov , D. Serebryakov

This paper describes the use of the time-of-flight (TOF) technique as a particle identification method for the HERMES experiment. The time-of-flight is measured by two 1x4 m^2 scintillation hodoscopes that initially were designed for the…

Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…

The aim of this work is to develop high precision Time-of-Flight (TOF) devices based on high refractive index solid Cherenkov radiators read out by silicon photomultipliers (SiPMs). Cherenkov light is prompt and therefore ideal for reaching…

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

The T2K ND280 upgrade aims to reduce the systematic uncertainty of the CP-violating phase, $\delta_{CP}$, to reject non-CP violation hypothesis at $3\sigma$ confidence level. A crucial component of the ND280 upgrade, alongside the Super…

Time-Of-Flight (TOF) is a noble technique that is used in Positron Emission Tomography (PET) imaging worldwide. The scintillator based imaging system that is being used around the world for TOF-PET is very expensive. Multi-gap Resistive…

A laser calibration system was developed for monitoring and calibrating time of flight (TOF) scintillating detector arrays. The system includes setups for both small- and large-scale scintillator arrays. Following test-bench…

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of…

仪器与探测器 · 物理学 2021-07-19 R. Abbott , A. Abreu , F. Addesa , M. Alhusseini , T. Anderson , Y. Andreev , A. Apresyan , R. Arcidiacono , M. Arenton , E. Auffray , D. Bastos , L. A. T. Bauerdick , R. Bellan , M. Bellato , A. Benaglia , M. Benettoni , R. Bertoni , M. Besancon , S. Bharthuar , A. Bornheim , E. Brücken , J. N. Butler , C. Campagnari , M. Campana , R. Carlin , P. Carniti , N. Cartiglia , M. Casarsa , O. Cerri , P. Checchia , H. Chen , S. Chidzik , F. Chlebana , F. Cossutti , M. Costa , B. Cox , I. Dafinei , F. De Guio , P. Debbins , D. del Re , A. Dermenev , E. Di Marco , K. Dilsiz , K. F. Di Petrillo , G. Dissertori , S. Dogra , U. Dosselli , I. Dutta , F. Caleb , C. Fernandez Madrazo , M. Fernandez , M. Ferrero , Z. Flowers , W. Funk , M. Gallinaro , S. Ganjour , M. Gardner , F. Geurts , A. Ghezzi , S. Gninenko , F. Golf , J. Gonzalez , C. Gotti , L. Gray , F. Guilloux , S. Gundacker , E. Hazen , S. Hedia , A. Heering , R. Heller , T. Isidori , R. Isocrate , R. Jaramillo , M. Joyce , K. Kaadze , A. Karneyeu , H. Kim , J. King , G. Kopp , M. Korjik , O. K. Koseyan , A. Kozyrev , N. Kratochwil , M. Lazarovits , A. Ledovskoy , H. Lee , J. Lee , A. Li , S. Li , W. Li , T. Liu , N. Lu , M. Lucchini , W. Lustermann , C. Madrid , M. Malberti , I. Mandjavize , J. Mao , Y. Maravin , D. Marlow , B. Marsh , P. Martinez del Arbol , B. Marzocchi , R. Mazza , C. McMahon , V. Mechinsky , P. Meridiani , A. Mestvirishvili , N. Minafra , A. Mohammadi , F. Monti , C. S. Moon , R. Mulargia , M. Murray , Y. Musienko , J. Nachtman , S. Nargelas , L. Narvaez , O. Neogi , C. Neu , T. Niknejad , M. Obertino , H. Ogul , G. Oh , I. Ojalvo , Y. Onel , G. Organtini , T. Orimoto , J. Ott , I. Ovtin , M. Paganoni , F. Pandolfi , R. Paramatti , A. Peck , C. Perez , G. Pessina , C. Pena , S. Pigazzini , O. Radchenko , N. Redaelli , D. Rigoni , E. Robutti , C. Rogan , R. Rossin , C. Rovelli , C. Royon , M. Ö. Sahin , W. Sands , F. Santanastasio , U. Sarica , I. Schmidt , R. Schmitz , J. Sheplock , J. C. Silva , F. Siviero , L. Soffi , V. Sola , G. Sorrentino , M. Spiropulu , D. Spitzbart , A. G. Stahl Leiton , A. Staiano , D. Stuart , I. Suarez , T. Tabarelli de Fatis , G. Tamulaitis , Y. Tang , B. Tannenwald , R. Taylor , E. Tiras , M. Titov , S. Tkaczyk , D. Tlisov , I. Tlisova , M. Tornago , M. Tosi , R. Tramontano , J. Trevor , C. G. Tully , B. Ujvari , J. Varela , S. Ventura , I. Vila , T. Wamorkar , C. Wang , X. Wang , M. Wayne , J. Wetzel , S. White , D. Winn , S. Wu , S. Xie , Z. Ye , G. B. Yu , G. Zhang , L. Zhang , Y. Zhang , Z. Zhang , R. Zhu

The new CDFII detector incorporates a Time-of-Flight detector (TOF), employing plastic scintillator bars and fine-mesh photomultipliers. Since August 2001 the TOF system has been fully instrumented and integrated into the CDFII data…

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are…

A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…

In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…

A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…

仪器与探测器 · 物理学 2016-06-01 M. Bonesini , R. Bertoni , A. deBari , M. Rossella

The SiPM-on-Tile technology for highly granular calorimeters, where small plastic scintillator tiles are directly read out with SiPMs, has been developed for the CALICE Analog Hadron Calorimeter, and has been adopted for parts of the…

仪器与探测器 · 物理学 2025-09-04 Fabian Hummer , Lorenz Emberger , Frank Simon

The advent of silicon photomultipliers has enabled big advances in high energy physics instrumentation, for example by allowing the construction of extremely granular hadronic calorimeters with photon sensors integrated into small…

仪器与探测器 · 物理学 2019-08-13 Christian Soldner

A prototype of DIRC-like Time-of-Flight detector (DTOF), including a pico-second time measurement electronics, is developed and tested preliminarily. The basic structure of DTOF is composed of a fused silica radiator connected to fast…

仪器与探测器 · 物理学 2018-06-08 Qiang Cao , Xin Li , Liwei Wang , Jie Kuang , Yonggang Wang , Cheng Li

We present results for time resolution studies performed on three different scintillating plastics and two silicon photo-multipliers. These studies are intended to determine whether scintillating plastic/silicon photo-multiplier systems can…