中文
相关论文

相关论文: A normal-pressure MWPC for beam diagnostics at RIB…

200 篇论文

Close-proximity offshore wind turbine inspection requires strict clearance control around large cylindrical structures under wind and model mismatch. Nominal Nonlinear Model Predictive Control (NMPC) may violate safety constraints when…

机器人学 · 计算机科学 2026-05-11 Giuseppe Silano , Martin Saska

The first phase of the long-baseline neutrino experiment, LBNE10, will use a broadband, high-energy neutrino beam with a 10-kt liquid argon TPC at 1300 km to study neutrino oscillation. In this paper, we describe potential upgrades to…

高能物理 - 实验 · 物理学 2013-07-04 M. Bishai , M. Diwan , S. Kettell , J. Stewart , R. Tschirhart , B. Viren , L. Whitehead , E. Worcester

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of…

仪器与探测器 · 物理学 2021-07-19 R. Abbott , A. Abreu , F. Addesa , M. Alhusseini , T. Anderson , Y. Andreev , A. Apresyan , R. Arcidiacono , M. Arenton , E. Auffray , D. Bastos , L. A. T. Bauerdick , R. Bellan , M. Bellato , A. Benaglia , M. Benettoni , R. Bertoni , M. Besancon , S. Bharthuar , A. Bornheim , E. Brücken , J. N. Butler , C. Campagnari , M. Campana , R. Carlin , P. Carniti , N. Cartiglia , M. Casarsa , O. Cerri , P. Checchia , H. Chen , S. Chidzik , F. Chlebana , F. Cossutti , M. Costa , B. Cox , I. Dafinei , F. De Guio , P. Debbins , D. del Re , A. Dermenev , E. Di Marco , K. Dilsiz , K. F. Di Petrillo , G. Dissertori , S. Dogra , U. Dosselli , I. Dutta , F. Caleb , C. Fernandez Madrazo , M. Fernandez , M. Ferrero , Z. Flowers , W. Funk , M. Gallinaro , S. Ganjour , M. Gardner , F. Geurts , A. Ghezzi , S. Gninenko , F. Golf , J. Gonzalez , C. Gotti , L. Gray , F. Guilloux , S. Gundacker , E. Hazen , S. Hedia , A. Heering , R. Heller , T. Isidori , R. Isocrate , R. Jaramillo , M. Joyce , K. Kaadze , A. Karneyeu , H. Kim , J. King , G. Kopp , M. Korjik , O. K. Koseyan , A. Kozyrev , N. Kratochwil , M. Lazarovits , A. Ledovskoy , H. Lee , J. Lee , A. Li , S. Li , W. Li , T. Liu , N. Lu , M. Lucchini , W. Lustermann , C. Madrid , M. Malberti , I. Mandjavize , J. Mao , Y. Maravin , D. Marlow , B. Marsh , P. Martinez del Arbol , B. Marzocchi , R. Mazza , C. McMahon , V. Mechinsky , P. Meridiani , A. Mestvirishvili , N. Minafra , A. Mohammadi , F. Monti , C. S. Moon , R. Mulargia , M. Murray , Y. Musienko , J. Nachtman , S. Nargelas , L. Narvaez , O. Neogi , C. Neu , T. Niknejad , M. Obertino , H. Ogul , G. Oh , I. Ojalvo , Y. Onel , G. Organtini , T. Orimoto , J. Ott , I. Ovtin , M. Paganoni , F. Pandolfi , R. Paramatti , A. Peck , C. Perez , G. Pessina , C. Pena , S. Pigazzini , O. Radchenko , N. Redaelli , D. Rigoni , E. Robutti , C. Rogan , R. Rossin , C. Rovelli , C. Royon , M. Ö. Sahin , W. Sands , F. Santanastasio , U. Sarica , I. Schmidt , R. Schmitz , J. Sheplock , J. C. Silva , F. Siviero , L. Soffi , V. Sola , G. Sorrentino , M. Spiropulu , D. Spitzbart , A. G. Stahl Leiton , A. Staiano , D. Stuart , I. Suarez , T. Tabarelli de Fatis , G. Tamulaitis , Y. Tang , B. Tannenwald , R. Taylor , E. Tiras , M. Titov , S. Tkaczyk , D. Tlisov , I. Tlisova , M. Tornago , M. Tosi , R. Tramontano , J. Trevor , C. G. Tully , B. Ujvari , J. Varela , S. Ventura , I. Vila , T. Wamorkar , C. Wang , X. Wang , M. Wayne , J. Wetzel , S. White , D. Winn , S. Wu , S. Xie , Z. Ye , G. B. Yu , G. Zhang , L. Zhang , Y. Zhang , Z. Zhang , R. Zhu

In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial…

仪器与探测器 · 物理学 2020-09-07 Gábor Galgóczi , Gergő Hamar , Péter Pázmándi , Dezső Varga

To promote the development of two-dimensional (2D) photonic crystals (PCs) based refractive-index (RI) biosensors, there is an urgent requirement of an effective approach to improve the RI sensitivity of 2D PCs (usually less than 500…

生物物理 · 物理学 2014-05-26 Liyong Jiang , Hong Wu , We Zhang , Xiangyin Li

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…

仪器与探测器 · 物理学 2025-10-16 The Tracker Group of the CMS Collaboration

In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1…

AXEL is a high pressure xenon gas TPC detector being developed for neutrinoless double-beta decay search. We use the proportional scintillation mode with a new electroluminescence light detection system to achieve high energy resolution in…

A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…

天体物理学 · 物理学 2009-11-11 Hua Feng , Philip Kaaret , Hans Andersson

The LPMWPC can be used as the {\Delta}E detector for the low-energy charged particle detection. In order to increase the transmittance, the wires were adopted as the cathode. This work investigated the LPMWPC signal characteristics of this…

Optical emission spectroscopy from a small-volume, 5 uL, atmospheric pressure RF-driven helium plasma was used in conjunction with Partial Least Squares Discriminant Analysis (PLS-DA) for the detection of trace concentrations of methane…

等离子体物理 · 物理学 2022-07-12 Tahereh Shah Mansouri , Hui Wang , Davide Mariotti , Paul Maguire

One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of…

A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors…

A new kind of Multi-gap Resistive Plate Chamber (MRPC) has been built for the large-area Muon Telescope Detector (MTD) for the STAR experiment at RHIC. These long read-out strip MRPCs (LMRPCs) have an active area of 87.0 x 17.0 cm2 and ten…

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood…

Measurement of the absolute value of the applied pressure in high-pressure muon and neutron experiments is a complicated task. It requires both the presence of a calibration material inside the sample volume as well as additional time for…

Knowledge of the beam energy at LEP2 is of primary importance to set the absolute energy scale for the measurement of the W-boson mass. The beam energy above 80 GeV is derived from continuous measurements of the magnetic bending field by 16…

高能物理 - 实验 · 物理学 2019-08-14 Michael D. Hildreth

The RIBLL2 in-flight separator at IMP, the secondary beam line between two storage rings at the \blue{\uwave{Heavy Ion Research Facility in Lanzhou (HIRFL-CSR)}}, has been commissioned to study the rare-isotope beam (RIB) physics at around…

In the DeeMe experiment, approximately $70\ \mathrm{GHz/mm^{2}}$ prompt-charged particles will hit the multi-wire proportional chambers (MWPCs) before signal electrons come. To avoid the space charge effect, we developed fast HV-switching…

仪器与探测器 · 物理学 2018-12-05 N. Teshima