相关论文: First Neutron Spectrometry Measurement at the HL-2…
A neutron detector based on EJ301 liquid scintillator has been employed at EAST to measure the neutron energy spectrum for D-D fusion plasma. The detector was carefully characterized in different quasi-monoenergetic neutron fields generated…
Advancements in high temperature superconducting technology have opened a path toward high-field, compact fusion devices. This new parameter space introduces both opportunities and challenges for diagnosis of the plasma. This paper presents…
It is very important to measure the plasma performances of fusion reactors such as fuel ion density, plasma temperature, fusion power, fast neutron energy, and neutron flux. Various diagnostic systems are needed to measure fast neutron…
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…
The principle of operation, design, registration system and main characteristics of a fast neutrons spectrometer are described. The spectrometer is intended for direct measurements of ultra low fluxes of fast neutrons. It is sensitive to…
A machine learning approach has been implemented to measure the electron temperature directly from the emission spectra of a tokamak plasma. This approach utilized a neural network (NN) trained on a dataset of 1865 time slices from…
In thermonuclear plasmas, plasma ions undergoing nuclear reactions emit gamma-rays with energies in the MeV range. Their spectroscopy can convey much plasma information, such as the DT fusion power, the spatial and velocity distributions of…
The photoneutron source (PNS, phase 1), an electron linear accelerator (linac)-based pulsed neutron facility that uses the time-of-flight (TOF) technique, was constructed for the acquisition of nuclear data from the thorium molten salt…
We report the performance and characterization of a custom-built hybrid detector consisting of BC501A liquid scintillator for fast neutrons and BC702 scintillator for thermal neutrons. The calibration and the resolution of the BC501A liquid…
We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and $^3$He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few…
Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…
A new multiplex-type inelastic neutron scattering spectrometer, HOrizontally Defocusing Analyzer Concurrent data Acquisition spectrometer (HODACA), was recently developed and built at the C1-1 cold neutron beam port in JRR-3. The…
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on…
A large area (0.5~m $\times$ 0.5~m) thermal neutron detector was developed based on 0.32~mm-thick $^{6}$LiF:ZnS(Ag) scintillator sheets. The detector was constructed for measurements of seasonal variations in low intensity thermal neutron…
A monitoring system for fast neutrons is planned in the COSINE experiment, a dark matter experiment with NaI crystals. We pursued several R&D approaches for a neutron detector using a liquid scintillator (LS). A pulse shape discrimination…
A novel algorithm for the discrimination of neutron and {\gamma}-ray with wavelet transform modulus maximum (WTMM) in an organic scintillation has been investigated. Voltage pulses arising from a BC501A organic liquid scintillation detector…
There is a key research issue to accurately select out neutron signals and discriminate gamma signals from a mixed radiation field in the neutron detection. This paper proposes a fractal spectrum discrimination approach by means of…
A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is…
Various neutron diagnostic tools are used in fusion reactors to evaluate different aspects of plasma performance, such as fusion power, power density, ion temperature, fast ion energy, and their spatial distributions. The stilbene…
Preliminary results of neutron spectra measurements from Pb, W, and Na targets irradiated by 0.8 and 1.6 GeV protons are presented. Measurements have been carried out using the proton beam extracted from the ITEP synchrotron and the TOF…