中文
相关论文

相关论文: Analytic Comparison between X-ray Fluorescence CT …

200 篇论文

The ultimate sensitivity of optical detection is limited by the signal-to-noise ratio (SNR). The first part of the paper shows that coherence plays an important role in the noise analysis. Although interference between an auxiliary wave and…

光学 · 物理学 2007-05-23 Taras Plakhotnik

Purpose: This study proposes a systematic method for determining the optimal x-ray tube settings/energy windows and fluence for minimal noise and maximum CNR in material density images obtained from DECT scans by fixing the subject size and…

医学物理 · 物理学 2023-08-02 Fatma Terzioglu , Emil Y. Sidky , Jp Phillips , Ingrid Reiser , Guillaume Bal , Xiaochuan Pan

In several image acquisition and processing steps of X-ray radiography, knowledge of the existence of metal implants and their exact position is highly beneficial (e.g. dose regulation, image contrast adjustment). Another application which…

图像与视频处理 · 电气工程与系统科学 2022-03-18 Fuxin Fan , Ludwig Ritschl , Marcel Beister , Ramyar Biniazan , Björn Kreher , Tristan M. Gottschalk , Steffen Kappler , Andreas Maier

Exoplanetary transit and stellar oscillation surveys require a very high precision photometry. The instrumental noise has therefore to be minimized. First, we perform a semi-analytical model of different noise sources. We show that the…

天体物理学 · 物理学 2015-05-13 Nicolas Crouzet , Tristan Guillot , Francois Fressin , Alain Blazit

The performance limits of the multilayer graphene nanoribbon (GNR) field-effect transistor (FET) are assessed and compared to those of monolayer GNR FET and carbon nanotube (CNT) FET. The results show that with a thin high-k gate insulator…

介观与纳米尺度物理 · 物理学 2009-12-14 Yijian Ouyang , Hongjie Dai , Jing Guo

Graph Neural Networks (GNNs) have proven to be powerful in many graph-based applications. However, they fail to generalize well under heterophilic setups, where neighbor nodes have different labels. To address this challenge, we employ a…

机器学习 · 计算机科学 2023-04-13 Yoonhyuk Choi , Jiho Choi , Taewook Ko , Chong-Kwon Kim

When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. In- terference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made…

In this study, we present the Graph Sub-Graph Network (GSN), a novel hybrid image classification model merging the strengths of Convolutional Neural Networks (CNNs) for feature extraction and Graph Neural Networks (GNNs) for structural…

计算机视觉与模式识别 · 计算机科学 2024-10-01 Aryan Singh , Pepijn Van de Ven , Ciarán Eising , Patrick Denny

Multispectral computed tomography (CT) enables advanced material characterization by acquiring energy-resolved projection data. However, since the incoming X-ray flux is be distributed across multiple narrow energy bins, the photon count…

Cone-beam computed tomography (CBCT) typically requires hundreds of X-ray projections, which raises concerns about radiation exposure. While sparse-view reconstruction reduces the exposure by using fewer projections, it struggles to achieve…

图像与视频处理 · 电气工程与系统科学 2024-11-05 Meng-Xun Li , Jin-Gang Yu , Yuan Gao , Cui Huang , Gui-Song Xia

Molecular Graph Neural Networks (GNNs) are increasingly common in drug discovery, particularly for Quantitative Structure-Activity Relationship (QSAR) studies; yet, their superiority compared to classical molecular featurisation approaches…

In the field of clinical medicine, computed tomography (CT) is an effective medical imaging modality for the diagnosis of various pathologies. Compared with X-ray images, CT images can provide more information, including multi-planar slices…

图像与视频处理 · 电气工程与系统科学 2024-03-08 Jing Hu , Qinrui Fan , Shu Hu , Siwei Lyu , Xi Wu , Xin Wang

Graph Convolutional Networks (GCNs) are widely used in a variety of applications, and can be seen as an unstructured version of standard Convolutional Neural Networks (CNNs). As in CNNs, the computational cost of GCNs for large input graphs…

计算机视觉与模式识别 · 计算机科学 2021-10-12 Moshe Eliasof , Benjamin Bodner , Eran Treister

Restoring high-quality CT images from low dose CT counterparts is an ill-posed, nonlinear problem to which Deep Learning approaches have been giving superior solutions compared to classical model-based approaches. In this article, a…

图像与视频处理 · 电气工程与系统科学 2019-10-16 Shabab Bazrafkan , Vincent Van Nieuwenhove , Jan Sijbers

We present an attention-based spatial graph convolution (AGC) for graph neural networks (GNNs). Existing AGCs focus on only using node-wise features and utilizing one type of attention function when calculating attention weights. Instead,…

计算机视觉与模式识别 · 计算机科学 2023-03-06 Yang Li , Yuichi Tanaka

The super $\tau$-charm facility (STCF) is a next-generation electron-positron collider with high luminosity proposed in China. The higher luminosity leads to increased background level, posing significant challenges for track reconstruction…

高能物理 - 实验 · 物理学 2025-07-15 Xiaoqian Jia , Xiaoshuai Qin , Teng Li , Xueyao Zhang , Xiaoqian Hu , Shuangbing Song , Hang Zhou , Xiaocong Ai , Jin Zhang , Xingtao Huang

A vertical partial gate carbon nanotube (CNT) field-effect transistor (FET), which is amenable to the vertical CNT growth process and offers the potential for a parallel CNT array channel, is simulated using a self-consistent atomistic…

介观与纳米尺度物理 · 物理学 2015-05-13 Youngki Yoon , James Fodor , Jing Guo

OVID-19 is a world-wide disease that has been declared as a pandemic by the World Health Organization. Computer Tomography (CT) imaging of the chest seems to be a valid diagnosis tool to detect COVID-19 promptly and to control the spread of…

图像与视频处理 · 电气工程与系统科学 2021-04-30 Matteo Polsinelli , Luigi Cinque , Giuseppe Placidi

Quantification of cardiac structures in non-contrast CT (NCCT) could improve cardiovascular risk stratification. However, setting a manual reference to train a fully convolutional network (FCN) for automatic segmentation of NCCT images is…

图像与视频处理 · 电气工程与系统科学 2019-08-22 Steffen Bruns , Jelmer M. Wolterink , Robbert W. van Hamersvelt , Tim Leiner , Ivana Išgum

CT protocol design and quality control would benefit from automated tools to estimate the quality of generated CT images. These tools could be used to identify erroneous CT acquisitions or refine protocols to achieve certain signal to noise…

计算机视觉与模式识别 · 计算机科学 2016-10-25 Sohini Roychowdhury , Nathan Hollraft , Adam Alessio