相关论文: Cavity beam position monitor system for the Accele…
IP-BPM (Interaction Point Beam Position Monitor) is an ultra high resolution cavity BPM to be used at ATF2, a test facility for ILC final focus system. Control of beam position in 2 nm precision is required for ATF2. Beam tests at ATF…
Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…
The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam…
A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a…
Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated…
Higher order mode (HOM) beam position monitors (BPM) are being developed for the 3.9 GHz third harmonic superconducting accelerating cavities at FLASH. The transverse beam position in a cavity can be determined utilizing beam-excited HOMs…
We report the design, operation and performance of a high-resolution, low-latency, bunch-by-bunch feedback system for nano-beam stabilisation. The system employs novel, ultra-low quality-factor cavity beam position monitors (BPMs), a…
The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time passive measurements without impacting the beam quality.…
In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both…
Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at…
This study is focused on the development of a HOM-based BPM system for the ACC39 module currently installed and in operation at FLASH. A similar system is anticipated to be installed at XFEL. Coupled inter-cavity modes are simulated…
Aiming at high precision beam position measurement of micron or sub-micron for Shanghai Soft X-ray free electron laser (SXFEL) facility which is being built in site of the Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute…
A high-precision intra-bunch-train beam orbit feedback correction system has been developed and tested in the ATF2 beamline of the Accelerator Test Facility at the High Energy Accelerator Research Organization in Japan. The system uses the…
ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback…
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of…
In order to pursue high-precision beam position measurements for the free-electron laser (FEL) facilities, cavity beam position monitor (CBPM) is employed to measure the transverse position which can meet the requirement of position…
The beam transport system for the Advanced Hydrotest Facility (AHF) anticipates multiple beam splitters [1]. Monitoring two separated beams in a common beam pipe in the splitter sections imposes certain requirements on diagnostics for these…
The control of beam phase relative to the accelerating RF field within a superconducting cavity is important in many accelerator applications and is of particular importance for a free electron laser facility. As standard practice, the…
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring…
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…