中文
相关论文

相关论文: Operational use of ionization profile monitors in …

200 篇论文

The ionization profile monitors (IPMs) are used to measure the beam size in synchrotrons. Both the Fermilab Recycler and Main Injector (MI) machines have IPMs. However, they were not well understood enough to provide confidence in their…

加速器物理 · 物理学 2023-07-17 B. Babacan , R. Ainsworth , K. J. Hazelwood , D. K Morris , P. Snopok

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. Two such monitors - one vertical and one horizontal - are being developed for installation in the…

加速器物理 · 物理学 2024-06-24 H. Piekarz , A. Romanov , R. Thurman-Keup , V. Shiltsev

The current program at Fermilab involves the construction of a new superconducting linear accelerator (LINAC) to replace the existing warm version. The new LINAC, together with other planned improvements, is in support of proton beam…

加速器物理 · 物理学 2023-10-03 R. Thurman-Keup , T. Folan , M. Mwaniki , S. Sas-Pawlik

For the PIP-II program, transverse emittance in the Fermilab Booster must remain well controlled at higher bunch intensities. 4-plate beam position monitors (BPMs) have a small but measurable quadrupole moment, making it possible to infer…

加速器物理 · 物理学 2025-11-26 M. A. Balcewicz , C. Y. Tan

The latest generation of IPMs installed in the Fermilab Main Injector and Recycler incorporate a 1 kG permanent magnet, a newly designed high-gain, rad-tolerant preamp, and a control grid to moderate the charge that is allowed to arrive on…

加速器物理 · 物理学 2015-02-11 J. R. Zagel , M. Alvarez , B. Fellenz , C. Jensen , C. Lundberg , E. McCrory , D. Slimmer , R. Thurman-Keup , D. Tinsley

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and…

加速器物理 · 物理学 2024-06-24 C. Y. Tan , M. Balcewicz

One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically,…

加速器物理 · 物理学 2023-10-05 R. Thurman-Keup , D. Slimmer , C. Lundberg , J. R. Zagel

The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…

加速器物理 · 物理学 2015-11-09 R. Thurman-Keup , M. Alvarez , J. Fitzgerald , C. Lundberg , P. Prieto , M. Roberts , J. Zagel , W. Blokland

The Main Injector (MI) at Fermilab currently produces high-intensity beams of protons at energies of 120 GeV for a variety of physics experiments. Acceleration of polarized protons in the MI would provide opportunities for a rich spin…

加速器物理 · 物理学 2017-12-29 M. Xiao , W. Lorenzon , C. Aldred

The planned neutrino program at Fermilab requires large proton beam intensities in excess of 2 MW. Measuring the transverse profiles of these high intensity beams is challenging and often depends on non-invasive techniques. One such…

加速器物理 · 物理学 2018-03-06 R. Thurman-Keup , M. Alvarez , J. Fitzgerald , C. Lundberg , P. Prieto , J. Zagel , W. Blokland

A high-performance Scintillator Ion Beam Monitor (SIBM) provides diagnostics across a range of isotopes, energies, and intensities employing a machine-vision camera with two novel scintillator targets movable into/out of the beam without…

The measurement of the longitudinal behavior of the accelerated particle beams at Fermilab is crucial to the optimization and control of the beam and the maximizing of the integrated luminosity for the particle physics experiments.…

Measurements of transverse profiles using Ionization Profile Monitors (IPMs) for high brightness beams are affected by the electromagnetic field of the beam. This interaction may cause a distortion of the measured profile shape despite…

加速器物理 · 物理学 2019-05-22 Dominik Vilsmeier , Mariusz Sapinski , Rahul Singh

The Main Injector (MI) was commissioned using data acquisition systems developed for the Fermilab Main Ring in the 1980s. New VME-based instrumentation was commissioned in 2006 for beam loss monitors (BLM)[2], which provided a more…

At the international linear collider, measurement of the beam profile at the interaction point is a key issue to achieve high luminosity. We report a simulation study on a new beam profile monitor, called the pair monitor, which uses the…

The intensity of charged particle beams at Fermilab must be kept within pre-determined safety and operational envelopes in part by assuring all beam within a few percent has been transported from any source to destination. Beam intensity…

加速器物理 · 物理学 2012-09-25 J. Crisp , B. Fellenz , J. Fitzgerald , D. Heikkinen , M. A. Ibrahim

The primary purpose of the Fermilab Recycler Ring Transverse Digital Damper System is to prevent instabilities due to high phase space densities of the cooled antiproton beam. The system was designed to facilitate Beam Transfer Function…

加速器物理 · 物理学 2008-12-18 N. Eddy , J. L. Crisp , M. Hu

Fermilab's Integrable Optics Test Accelerator is an electron storage ring designed for testing advanced accelerator physics concepts, including implementation of nonlinear integrable beam optics and experiments on optical stochastic…

加速器物理 · 物理学 2013-01-29 S. Nagaitsev , A. Valishev , V. V. Danilov , D. N. Shatilov

We describe the status of the Main Injector particle production Experiment (MIPP) at Fermilab which has to date acquired 18 million events of particle interactions using (5 GeV/c-120 GeV/c) $\pi^\pm, K^\pm$ and $p^\pm$ beams on various…

高能物理 - 实验 · 物理学 2008-11-26 Rajendran Raja

We outline the design of beam experiments for the electron linac at the Fermilab Accelerator Science and Technology (FAST) facility and for the Integrable Optics Test Accelerator (IOTA), based on synchrotron light emitted by the electrons…

‹ 上一页 1 2 3 10 下一页 ›