中文
相关论文

相关论文: CT to Cone-beam CT Deformable Registration With Si…

200 篇论文

Registration of brain MRI images requires to solve a deformation field, which is extremely difficult in aligning intricate brain tissues, e.g., subcortical nuclei, etc. Existing efforts resort to decomposing the target deformation field…

图像与视频处理 · 电气工程与系统科学 2022-04-27 Jinxin Lv , Zhiwei Wang , Hongkuan Shi , Haobo Zhang , Sheng Wang , Yilang Wang , Qiang Li

The cone beam computed tomography (CBCT) technique was first inserted in dental imaging 15 years ago. Due to this technique 3D imaging in dentistry has been excessively changed. The purpose beyond using CBCT instead of computed tomography…

医学物理 · 物理学 2018-12-11 Kaspar Höschel , Janos Juhasz

Paired inspiratory-expiratory CT scans enable the quantification of gas trapping due to small airway disease and emphysema by analyzing lung tissue motion in COPD patients. Deformable image registration of these scans assesses regional lung…

In X-ray computed tomography (CT) imaging, the choice of reconstruction kernel is crucial as it significantly impacts the quality of clinical images. Different kernels influence spatial resolution, image noise, and contrast in various ways.…

图像与视频处理 · 电气工程与系统科学 2025-02-24 Hemant Kumar Aggarwal , Antony Jerald , Phaneendra K. Yalavarthy , Rajesh Langoju , Bipul Das

Objective: Cone-beam computed tomography (CBCT) provides a low-dose imaging alternative to conventional CT, but suffers from noise, scatter, and artifacts that degrade image quality. Synthetic CT (sCT) aims to translate CBCT to high-quality…

医学物理 · 物理学 2025-09-23 Alzahra Altalib , Chunhui Li , Alessandro Perelli

Objective. Dual-energy computed tomography (DECT) has the potential to improve contrast, reduce artifacts and the ability to perform material decomposition in advanced imaging applications. The increased number or measurements results with…

图像与视频处理 · 电气工程与系统科学 2022-03-14 Alessandro Perelli , Suxer Alfonso Garcia , Alexandre Bousse , Jean-Pierre Tasu , Nikolaos Efthimiadis , Dimitris Visvikis

To obtain high-quality positron emission tomography (PET) scans while reducing radiation exposure to the human body, various approaches have been proposed to reconstruct standard-dose PET (SPET) images from low-dose PET (LPET) images. One…

图像与视频处理 · 电气工程与系统科学 2023-08-22 Zeyu Han , Yuhan Wang , Luping Zhou , Peng Wang , Binyu Yan , Jiliu Zhou , Yan Wang , Dinggang Shen

Cone Beam CT (CBCT) plays a crucial role in Adaptive Radiation Therapy (ART) by accurately providing radiation treatment when organ anatomy changes occur. However, CBCT images suffer from scatter noise and artifacts, making relying solely…

图像与视频处理 · 电气工程与系统科学 2023-08-08 Linjie Fu , Xia Li , Xiuding Cai , Dong Miao , Yu Yao , Yali Shen

While medical images such as computed tomography (CT) are stored in DICOM format in hospital PACS, it is still quite routine in many countries to print a film as a transferable medium for the purposes of self-storage and secondary…

图像与视频处理 · 电气工程与系统科学 2022-03-14 Quan Quan , Qiyuan Wang , Yuanqi Du , Liu Li , S. Kevin Zhou

This paper provides a fast and patient-specific scatter artifact correction method for cone-beam computed tomography (CBCT) used in image-guided interventional procedures. Due to increased irradiated volume of interest in CBCT imaging,…

医学物理 · 物理学 2015-01-20 Wei Zhao , Stephen Brunner , Kai Niu , Sebastian Schafer , Kevin Royalty , Guang-Hong Chen

In recent years, the integration of advanced imaging techniques and deep learning methods has significantly advanced computer-aided diagnosis (CAD) systems for breast cancer detection and classification. Transformers, which have shown great…

计算机视觉与模式识别 · 计算机科学 2025-07-22 Mahtab Ranjbar , Mehdi Mohebbi , Mahdi Cherakhloo , Bijan Vosoughi. Vahdat

This study aimed to propose a denoising method for dynamic contrast-enhanced computed tomography (DCE-CT) perfusion studies using a three-dimensional deep image prior (DIP), and to investigate its usefulness in comparison with total…

医学物理 · 物理学 2023-04-04 Kenya Murase

Medical image registration is a fundamental task in medical image analysis, enabling the alignment of images from different modalities or time points. However, intensity inconsistencies and nonlinear tissue deformations pose significant…

计算机视觉与模式识别 · 计算机科学 2026-04-23 Eytan Kats , Christoph Grossbroehmer , Ziad Al-Haj Hemidi , Fenja Falta , Wiebke Heyer , Mattias P. Heinrich

Accurate, automated lesion detection in Computed Tomography (CT) is an important yet challenging task due to the large variation of lesion types, sizes, locations and appearances. Recent work on CT lesion detection employs two-stage region…

图像与视频处理 · 电气工程与系统科学 2019-06-07 Martin Zlocha , Qi Dou , Ben Glocker

Deformable image registration (DIR) involves optimization of multiple conflicting objectives, however, not many existing DIR algorithms are multi-objective (MO). Further, while there has been progress in the design of deep learning…

图像与视频处理 · 电气工程与系统科学 2024-02-27 Monika Grewal , Henrike Westerveld , Peter A. N. Bosman , Tanja Alderliesten

This paper introduces a novel method for reconstructing cone beam computed tomography (CBCT) images for arbitrary orbits using a differentiable shift-variant filtered backprojection (FBP) neural network. Traditional CBCT reconstruction…

计算机视觉与模式识别 · 计算机科学 2024-10-22 Chengze Ye , Linda-Sophie Schneider , Yipeng Sun , Mareike Thies , Siyuan Mei , Andreas Maier

Motion correction of dynamic contrast enhanced magnetic resonance images (DCE-MRI) is a challenging task, due to changes in image appearance. In this study a groupwise registration, using a principle component analysis (PCA) based metric,1…

图像与视频处理 · 电气工程与系统科学 2019-08-23 Mariëlle J. A. Jansen , Wouter B. Veldhuis , Maarten S. van Leeuwen , Josien P. W. Pluim

The analysis of multi-modality positron emission tomography and computed tomography (PET-CT) images for computer aided diagnosis applications requires combining the sensitivity of PET to detect abnormal regions with anatomical localization…

计算机视觉与模式识别 · 计算机科学 2019-10-29 Ashnil Kumar , Michael Fulham , Dagan Feng , Jinman Kim

X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took…

In current clinical practice, noisy and artifact-ridden weekly cone-beam computed tomography (CBCT) images are only used for patient setup during radiotherapy. Treatment planning is done once at the beginning of the treatment using…

图像与视频处理 · 电气工程与系统科学 2022-01-02 Navdeep Dahiya , Sadegh R Alam , Pengpeng Zhang , Si-Yuan Zhang , Anthony Yezzi , Saad Nadeem