相关论文: Signal propagation and spark mitigation in resisti…
The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or…
In this work, we have tried to develop a detailed understanding of the physical processes occurring in those variants of Micro Pattern Gas Detectors (MPGDs) that share micro hole and micro strip geometry, like GEM, MHSP and MSGC etc. Some…
The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…
The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 75 institutes from 25 countries bundle their effort, experience and resources to develop…
The Micro Pixel Chamber (mu-PIC) using resistive electrodes has been developed and tested. The surface cathodes are made from resistive material, by which the electrical field is reduced when large current is flowed. Two-dimensional…
The data compression technology now is fully developed and widely used in many fields such as communication, multi-media, image information processing and so on. The large physical experiments, especially the ones with Micro-pattern Gas…
We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a…
The conventional readout method of the RPC detector uses two sets of orthogonal readout strips placed at the both sides of the gas gap to collect signals of opposite polarities to obtain space points. A new readout method utilizing the…
An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our…
Gaseous detectors are fundamental components of all present and planned high energy physics experiments. Over the past decade two representatives (GEM, Micromegas) of the Micro-Pattern Gas Detector (MPGD) concept have become increasingly…
Nowadays RPCs are in a booming phase: they are successfully used in many experiments, including LHC; there are ambitious plans to use them in several upgrade detectors and in some new experiments as well as in various applications. The aim…
Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…
The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution…
We experimentally and computationally analyze impact-shock-induced stress wave propagation in packings of disordered flexible fibers. We find that dispersive wave propagation, associated with large stress attenuation, occurs much more…
The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a…
We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides an uniform 200…
Crosstalk characteristics such as pulse amplitude and shape are studied with a simple PSpice model of the capacitive couplings within an MPGD. The crosstalk pulse shape can be understood as due to a CR-differentiator. Crosstalk can occur…
This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of…
Transition Radiation Detectors (TRDs) are useful for electron identification and hadron suppression in high energy nuclear and particle physics experiments. Conventional wire-chamber TRDs face operational limitations due to space charge…