相关论文: Verifying the accuracy of the TITAN Penning-trap m…
We propose a novel type of precision laser spectrometer for trapped, highly charged ions nearly at rest. It consists of a cylindrical open-endcap Penning trap in which an externally produced bunch of highly charged ions can be confined and…
An in-trap decay spectroscopy setup has been developed and constructed for use with the TITAN facility at TRIUMF. The goal of this device is to observe weak electron-capture (EC) branching ratios for the odd-odd intermediate nuclei in the…
The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility…
The TITAN facility at TRIUMF has recently initiated a program of performing decay spectroscopy measurements in an electron-beam ion-trap (EBIT). The unique environment of the EBIT provides backing-free storage of the radioactive ions, while…
The KArlsruhe TRItium Neutrino experiment KATRIN aims at improving the upper limit of the mass of the electron antineutrino to about 0.2 eV (90% c.l.) by investigating the beta-decay of tritium gas molecules. The experiment is currently…
A tandem Penning trap facility has been designed and is under construction at the Texas A&M University Cyclotron Institute (TAMU-TRAP). The initial experimental program will be the study of correlation parameters for T=2 superallowed…
Single-atom quantum sensors offer high spatial resolution and high sensitivity to electric and magnetic fields. Among them, trapped ions offer exceptional performance in sensing electric fields, which has been used in particular to probe…
We use an electric-dipole laser-driven transition to precisely measure the cyclotron-frequency ratios of the pairs $^{42}$Ca$^+$-$^{40}$Ca$^+$, $^{44}$Ca$^+$-$^{40}$Ca$^+$ and $^{48}$Ca$^+$-$^{40}$Ca$^+$ in a 7-tesla Penning trap. A single…
A newly constructed apparatus at the National Institute of Standards and Technology (NIST) is designed for the isolation, manipulation, and study of highly charged ions. Highly charged ions are produced in the NIST electron-beam ion trap…
Significant systematic errors in high-precision Penning trap mass spectrometry can result from electric and magnetic field imperfections. An experimental procedure to minimize these uncertainties is presented for the on-line Penning trap…
Accurate measurements with implications in many branches in Physics have been accessed using Penning traps and conventional techniques within a temperature regime where each eigenmotion of a charged particle is still a classical harmonic…
In this letter, we report a new mass for $^{11}$Li using the trapping experiment TITAN at TRIUMF's ISAC facility. This is by far the shortest-lived nuclide, $t_{1/2} = 8.8 \rm{ms}$, for which a mass measurement has ever been performed with…
Penning traps, renowned for their unparalleled precision in determining fundamental properties such as mass and magnetic moments, are cornerstone instruments in modern physics. Their applications span from nuclear structure studies to…
The possibility to apply active feedback to a single ion in a Penning trap using a fully digital system is demonstrated. Previously realized feedback systems rely on analog circuits that are susceptible to environmental fluctuations and…
This review article describes the trapping of charged particles. The main principles of electromagnetic confinement of various species from elementary particles to heavy atoms are briefly described. The preparation and manipulation with…
The research reactor TRIGA Mainz is an ideal facility to provide neutron-rich nuclides with production rates sufficiently large for mass spectrometric and laser spectroscopic studies. Within the TRIGA-SPEC project, a Penning trap as well as…
We present the design, construction and characterization of an experimental system capable of supporting a broad class of quantum simulation experiments with hundreds of spin qubits using Be-9 ions in a Penning trap. This article provides a…
We report on the design and testing of an array of Penning ion traps made from printed circuit board. The system enables fast shuttling of ions from one trapping zone to another, which could be of use in quantum information processing. We…
Penning traps are made extremely compact by embedding rare-earth permanent magnets in the electrode structure. Axially-oriented NdFeB magnets are used in unitary architectures that couple the electric and magnetic components into an…
A new procedure to prepare isomerically clean samples of ions with a mass resolving power of more than 100,000 has been developed at the JYFLTRAP tandem Penning trap system. The method utilises a dipolar rf-excitation of the ion motion with…