中文
相关论文

相关论文: Verifying the accuracy of the TITAN Penning-trap m…

200 篇论文

The study of nuclei farther from the valley of $\beta$-stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore…

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental…

The neutron-rich mass region around $A\approx100$ presents challenges for modeling the astrophysical $r$-process because of rapid shape transitions. We report on mass measurements using the TITAN Penning trap at TRIUMF-ISAC to attain more…

The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut f\"ur Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy…

A novel Penning trap tower consisting of five compensated cylindrical Penning traps is developed for the PENTATRAP mass spectrometer at the Max-Planck-Institut f\"ur Kernphysik in Heidelberg, Germany. An analytical expression for the…

原子物理 · 物理学 2015-05-30 C. Roux , Ch. Böhm , A. Dörr , S. Eliseev , S. George , Yu. Novikov , J. Repp , S. Sturm , S. Ulmer , K. Blaum

The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving…

The technique of Penning trap mass spectrometry is briefly reviewed particularly in view of precision experiments on unstable nuclei, performed at different facilities worldwide. Selected examples of recent results emphasize the importance…

核实验 · 物理学 2009-09-24 K. Blaum , Sz. Nagy , G. Werth

The Penning-trap electronic-detection technique that offers the precision and sensitivity requested in mass spectrometry for fundamental studies in nuclear and particle physics has not been proven yet to be universal. This has motivated the…

At Central Michigan University we are developing a high-precision Penning trap mass spectrometer (CHIP-TRAP)that will focus on measurements with long-lived radioactive isotopes. CHIP-TRAP will consist of a pair of hyperbolic…

Trapped ions in radio-frequency traps are among the leading approaches for realizing quantum computers, due to high-fidelity quantum gates and long coherence times. However, the use of radio-frequencies presents a number of challenges to…

This article presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam…

The Texas A&M University Penning Trap facility is an upcoming ion trap that will be used to search for possible scalar currents in T=2 superallowed $\beta$-delayed proton decays, which, if found, would be an indication of physics beyond the…

We report on the precise measurement of the atomic mass of a single proton with a purpose-built Penning-trap system. With a precision of 32 parts-per-trillion our result not only improves on the current CODATA literature value by a factor…

The precise knowledge of the atomic masses of light atomic nuclei, e.g. the proton, deuteron, triton and helion, is of great importance for several fundamental tests in physics. However, the latest high-precision measurements of these…

We present Penning-trap mass measurements of neutron-rich 44,47-50K and 49,50Ca isotopes carried out at the TITAN facility at TRIUMF-ISAC. The 44K mass measurement was performed with a charge-bred 4+ ion utilizing the TITAN EBIT, and agrees…

We present precision Penning-trap mass measurements of neutron-rich calcium and potassium isotopes in the vicinity of neutron number N=32. Using the TITAN system the mass of $^{51}$K was measured for the first time, and the precision of the…

Positrons are accumulated within a Penning trap designed to make more precise measurements of the positron and electron magnetic moments. The retractable radioactive source used is weak enough to require no license for handling radioactive…

仪器与探测器 · 物理学 2023-11-14 S. Fogwell Hoogerheide , J. C. Dorr , E. Novitski , G. Gabrielse

In Penning traps electromagnetic forces are used to confine charged particles under well-controlled conditions for virtually unlimited time. Sensitive detection methods have been developed to allow observation of single stored ions. Various…

原子物理 · 物理学 2022-03-16 Klaus Blaum , Sergey Eliseev , Sven Sturm

A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its…

A precision mass investigation of the neutron-rich titanium isotopes $^{51-55}$Ti was performed at TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the $N=32$ shell closure and the overall…