相关论文: Technique for high axial shielding factor performa…
The feasibility of shielding axial magnetic fields up to 1.4~T, using a Bi-2212 hollow cylinder, is investigated at a temperature of 4.2~K. The residual magnetic flux density along the axis of the tube is measured at external fields of 1~T…
A passive magnetic shield was designed and constructed for magnetometer tests for the future neutron electric dipole moment experiment at TRIUMF. The axial shielding factor of the magnetic shield was measured using a magnetometer based on…
We have experimentally studied the magnetic shielding properties of a cylindrical shell of BiPbSrCaCuO subjected to low frequency AC axial magnetic fields. The magnetic response has been investigated as a function of the dimensions of the…
We show that tubes of melt cast Bi-2212 used as current leads for LTS magnets can also act as efficient magnetic shields. The magnetic screening properties under an axial DC magnetic field are characterized at several temperatures below the…
We present a magnetically shielded environment with a damping factor larger than one million at the mHz frequency regime and an extremely low field and gradient over an extended volume. This extraordinary shielding performance represents an…
Magnetically-sensitive experiments and newly-developed quantum technologies with integrated high-permeability magnetic shields require increasing control of their magnetic field environment and reductions in size, weight, power and cost.…
Thin flexible sheets of high-permeability FINEMET foils encased in thin plastic layers have been used to shield various types of 20-cm-diameter photomultiplier tubes from ambient magnetic fields. In the presence of the Earth's magnetic…
We present results from studies of the effectiveness of an overlap technique for forming a magnetic seal across a gap at the boundary between a cylindrical magnetic shield and an end-cap. In this technique a thin foil of magnetic material…
We present the technical design and characteristics of the magnetic shield developed for 20" PMTs of the low-background OSIRIS facility. A ribbon of amorphous alloy with the extreme magnetic permeability was used in its design providing the…
We report on the design, construction, and performance of a compact magnetic shield that facilitates a controlled, low-noise environment for experiments with ultracold atomic gases. The shield was designed to passively attenuate external…
The magnetic shield plays an important role in magnetic near-field control. However, the requirements of efficient, ultrathin, lightweight and cheap are still the challenges. Here, we firstly propose a composite metamaterial in which the…
Metal meshes have emerged as an important class of flexible transparent electrodes. We report on the characteristics of a new class of asymmetric meshes, tiled using a recently-discovered family of pentagons. Micron-scale meshes were…
The effect of passive magnetic shielding on dc magnetic field gradients imposed by both external and internal sources is studied. It is found that for concentric cylindrical or spherical shells of high permeability material, higher order…
Stacks of high-temperature superconducting tape annuli can be used as magnetic shields operating efficiently for both axial and transverse fields. However, due to their layered geometry and hybrid electrical and magnetic properties,…
A quasi time constant for magnetic domain relaxation of Metglas 20605SA1 has been measured to be 2.6 hours. The effective relative magnetic permeability has been measured to be 57,000 after relaxation.
Hybrid magnetic shields with both active field generating components and high-permeability magnetic shielding are increasingly needed for a variety of technologies and experiments that require precision-controlled magnetic field…
We report on the design, construction, and characterization of a 10 m-long high-performance magnetic shield for Very Long Baseline Atom Interferometry (VLBAI). We achieve residual fields below 4 nT and longitudinal inhomogeneities below 2.5…
Transition edge sensor (TES) microcalorimeters and bolometers are used for a variety of applications. The sensors are based on the steep temperature-dependent resistance of the normal-to-superconducting transition, and are thus…
Highly flexible electromagnetic interference (EMI) shielding material with excellent shielding performance is of great significance to practical applications in next-generation flexible devices. However, most EMI materials suffer from…
Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. We demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in…