相关论文: 30 kV coaxial vacuum-tight feedthrough for operati…
Voltages above a hundred kilo-volt will be required to generate the drift field of future very large liquid Argon Time Projection Chambers. The most delicate component is the feedthrough whose role is to safely deliver the very high voltage…
The purpose, design specifications, construction techniques, and testing methods are described for the high voltage feedthrough ports and filters of the ATLAS Liquid Argon calorimeters. These feedthroughs carry about 5000 high voltage wires…
Highly energetic ultrashort electron bunches have the potential to reveal the ultrafast structural dynamics in relatively thicker in-liquid samples. However, direct current (DC) voltages higher than 100 kV are exponentially difficult to…
A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable…
The prevalent use of large volume liquid argon detectors strongly motivates the development of novel readout and monitoring technology which functions at cryogenic temperatures. This paper presents the development of a cryogenic CMOS camera…
The careful filtering of microwave electromagnetic radiation is critical for controlling the electromagnetic environment for experiments in solid-state quantum information processing and quantum metrology at millikelvin temperatures. We…
We demonstrate a method to produce vacuum tight, metal free, bakeable and alkali compatible feedthroughs for optical fibers. The manufacturing process mainly relies on encasing fibers made of fused silica with glass materials with lower…
We describe the design and implementation of a sixty-four pin non-magnetic cryogenic vacuum feedthrough.
A robust cryogenic infrastructure in form of a wired, thermally optimized dilution refrigerator is essential for present and future solid-state based quantum processors. Here, we engineer an extensible cryogenic setup, which minimizes…
There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and successfully tested special designs of gaseous detectors with…
A best practice guide for assembling and testing a simple and inexpensive system feeding an optical fibre into a high pressure and temperature environment is presented. A standard Swagelok type connector is tested together with different…
High voltage breakdown in liquid argon is an important concern in the design of liquid argon time projection chambers, which are often used as neutrino and dark matter detectors. We have made systematic measurements of breakdown voltages in…
Designs of high-voltage (HV) systems for creating a drift electric field in liquid argon TPCs are reviewed. In ongoing experiments systems capable of approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of up to 1.5 m.…
We adopt thick-film technology to produce ultra high vacuum compatible interfaces for electrical signals. These interfaces permit voltages of hundreds of Volts and currents of several Amperes and allow for very compact vacuum setups, useful…
We describe the design and performance of a scanning tunneling microscope (STM) which operates at a base temperature of 30 mK in a vector magnetic field. The cryogenics is based on an ultra-high vacuum (UHV) top-loading wet dilution…
For low-temperature experiments such as liquid xenon dark matter detectors, it is crucial to read out detector signals from cryostats. Traditionally, photoelectrical signals are transmitted from the cryogenic region to the outside using…
Some of the main neutrino oscillation and dark matter experiments have chosen time projection chambers (TPC) filled with liquid argon (LAr) as their technology for the next generation of detectors. Because of its typical drift length of…
Quantum technologies offer unprecedented capabilities in computation and secure information transfer. Their implementation requires qubits to operate at cryogenic temperatures (CT) while control and readout electronics typically still…
Cryogenic systems necessitate extensive data transmission between room-temperature and cryogenic environments, as well as within the cryogenic temperature domain. High-speed, low-power data transmission is pivotal to enabling the deployment…
Optical illumination of quantum-dot qubit devices at cryogenic temperatures, while not well studied, is often used to recover operating conditions after undesired shocking events or charge injection. Here, we demonstrate systematic…