相关论文: Investigating reciprocity failure in 1.7-micron cu…
Flux dependent non-linearity (reciprocity failure) in HgCdTe near infrared detectors can severely impact an instrument's performance, in particular with respect to precision photometric measurements. The cause of this effect is presently…
A detailed study of reciprocity failure in four 1.7 micron cutoff HgCdTe near-infrared detectors is presented. The sensitivity to reciprocity failure is approximately 0.1%\decade over up to five orders of magnitude in illumination…
Infrared hybridized detectors are widely used in astronomy, and their performance can be degraded by image persistence. This results in remnant images that can persist in the detector for many hours, contaminating any subsequent…
In this paper results of Edge-TCT and I-V measurements with passive test structures made in LFoundry 150 nm HV-CMOS process on p-type substrates with different initial resistivities ranging from 0.5 to 3 k$\Omega$cm are presented. Samples…
We measure the nonlinearity of a telecom-wavelength superconducting nanowire single-photon detector via incoherent beam combination. At typical photon count rates and detector bias current, the observed relative deviation from a perfectly…
Reciprocity is when the scattering amplitude of wave propagation satisfies a symmetry property, connecting a scattering process with an appropriate reversed one. We report on an experiment using nuclear resonance scattering of synchrotron…
We report on the demonstration of an effective, nonlinearity-induced non-reciprocal behavior in a single non-magnetic multi-mode Taiji resonator. Non-reciprocity is achieved by a combination of an intensity-dependent refractive index and of…
Circumventing the reciprocity invariance has posed an interesting challenge in the design of modern devices for wave engineering. In passive devices, operating the device in the nonlinear response regime is a common means for realizing…
Absolute measurements of neutron fluence are an essential prerequisite of neutron-induced cross section measurements, neutron beam lines characterization and dosimetric investigations. The H(n,p) elastic scattering cross section is a very…
Dynamic reciprocity imposes stringent performance constraints on nonlinear optical devices such as isolators and circulators. The seminal result by Shi et al. establishes that nonlinear optical devices relying on the intensity-dependent…
The 3He-based neutron detectors are no longer the default solution for neutron scattering applications. Both the inability of fulfilling the requirements in performance, needed for the new instruments, and the shortage of 3He, drove a…
The University of Rochester infrared detector group is working together with Teledyne Imaging Sensors to develop HgCdTe 15 $\mu m$ cutoff wavelength detector arrays for future space missions. To reach the 15 $\mu m$ cutoff goal, we took an…
We study the nonlinearity (NL) in the conversion from charge to voltage in infrared detectors (HXRG) for use in precision astronomy. We present laboratory measurements of the NL function of a H2RG detector and discuss the accuracy to which…
The PROSPECT experiment is designed to perform precise searches for antineutrino disappearance at short distances (7 - 9~m) from compact nuclear reactor cores. This Letter reports results from a new neutrino oscillation analysis performed…
Thin pad detectors made from 75 $\mu$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that…
Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$\Omega$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation.…
We report a newly identified nonlinearity in H4RG-10 near-infrared detectors operating under moderately elevated-temperature conditions (114 K). This component, that potentially arises from illumination-independent defect currents,…
By means of C-OTDR (Correlation - Optical Time Domain Reflectometry), we measured the latency of100 km fiber with an accuracy of a few picoseconds. Based on iterating 49 measurements, we calculated a standard deviation of 12 ps between the…
Measuring slow neutrons is difficult when the radiation field also contains charged particles and fast neutrons, especially when the radiation composition is not known in advance. In this work, we present a tested method to measure slow…
We study the breaking of reciprocity in non-Hermitian coupled photonic waveguides by the simultaneous action of the nonlinear effect of saturable absorption, and the presence of exceptional points. The nonlinear response of such a system is…