相关论文: ELISA: a cryocooled 10 GHz oscillator with 10-15 f…
We report here the characterization (temperature coefficients and noise level) of selected voltage references in the frequency range from 10^(-5) to 10 Hz. The goal of this work is to update previous studies, with a characterization at…
LISA is an array of three spacecraft flying in an approximately equilateral triangle configuration, which will be used as a low-frequency detector of gravitational waves. Recently a technique has been proposed for suppressing the phase…
Low-noise temperature measurements at frequencies in the milli-Hertz range are needed in the LISA and LISA PathFinder (LPF). The required temperature stability for LISA is around 10 uK/sqrt(Hz) at frequencies down to 0.1 mHz. In this paper…
The advancement of technologies for the precise interrogation of molecules offers exciting possibilities for new studies in the realms of precision spectroscopy and quantum technologies. Experiments in these domains often address molecular…
Using an ultrastable continuous-wave laser at 580 nm we performed spectral hole burning of Eu$^{3+}$:Y$_{2}$SiO$_{5}$ at very high spectral resolution. Essential parameters determining the usefulness as a "macroscopic" frequency reference:…
A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first stage,…
We consider frequency fluctuations in self-sustained oscillators based on nonlinear underdamped resonators. An important type of such resonators are nano- and micro-electro-mechanical systems. Various noise sources are considered, with the…
Laser frequency stabilization is a critical part of the interferometry measurement system of space-based gravitational wave observatories such as the Laser Interferometer Space Antenna (LISA). Arm locking as a proposed frequency…
We establish a testbed system for the development of high-sensitivity Electron Spin Resonance (ESR) techniques for small samples at cryogenic temperatures. Our system consists of a Niobium Nitride thin-film planar superconducting…
Interferometric wavelength meters have attained frequency resolutions down to the MHz range. In particular, Fizeau interferometers, which have no moving parts, are becoming a popular tool for laser characterization and stabilization. In…
We report on two ultrastable lasers each stabilized to independent silicon Fabry-P\'erot cavities operated at 124 K. The fractional frequency instability of each laser is completely determined by the fundamental thermal Brownian noise of…
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and…
A fundamental limit to the stability of a single-ion optical frequency standard is set by quantum noise in the measurement of the internal state of the ion. We discuss how the interrogation sequence and the processing of the atomic…
We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint…
This paper presents a novel method for laser frequency stabilisation in the Laser Interferometer Space Antenna (LISA) mission by locking a laser to two stable length references - the arms of the interferometer and an on-board optical…
We report on the development of a sub-kelvin, single-crystal silicon Fabry-Perot cavity. Operating such a cavity below 1~K should reduce the thermal noise limit of the cavity, and by this way address the current limitations of ultrastable…
Compact and robust frequency-stabilized laser sources are critical for a variety of fields that require stable frequency standards, including field spectroscopy, radio astronomy, microwave generation, and geophysical monitoring. In this…
We report in detail the design process and performance of an auto-locking ultra-stable laser with sub-hertz linewidth at the first time. The laser frequency is automatically stabilized to an optical reference cavity with a home-made…
Arm-locking is a technique for stabilizing the frequency of a laser in an inter-spacecraft interferometer by using the spacecraft separation as the frequency reference. A candidate technique for future space-based gravitational wave…
We report on a long-term monitoring campaign of 1E 1841-045, the 12-s anomalous X-ray pulsar and magnetar candidate at the center of the supernova remnant Kes 73. We have obtained approximately monthly observations of the pulsar with the…