中文
相关论文

相关论文: High Spatial Resolution Fast-Neutron Imaging Detec…

200 篇论文

A new instrument for high resolution imaging of fast-neutrons is presented here. It is designed for energy selective radiography in nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. The device presented here is based on hydrogenous…

Two detection systems based on optical readout were developed: a. Integrative optical detector A 2nd generation of Time-Resolved Integrative Optical Neutron (TRION) detector was developed. It is based on an integrative optical technique,…

仪器与探测器 · 物理学 2017-05-01 Ilan Mor

One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of…

仪器与探测器 · 物理学 2009-11-10 V. Dangendorf , A. Breskin , R. Chechik , M. Goldberg , G. Laczko , I. Mor , M. Reginatto , D. Vartsky

A new method for directional fast neutron detection is proposed based on a neutron time projection chamber (TPC) and position-sensitive plastic scintillation detectors. The detection system can efficiently locate the approximate location of…

仪器与探测器 · 物理学 2019-07-11 Yidong Fu , Yang Tian , Yulan Li , Jian Yang , Jin Li

Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The…

We have analyzed and compared the performance of two novel fast-neutron imaging methods with time-of-flight spectroscopy capability. Using MCNP and GEANT code simulations of neutron and charged-particle transport in the detectors, key…

仪器与探测器 · 物理学 2009-11-10 D. Vartsky , I. Mor , M. B. Goldberg , I. Mardor , G. Feldman , D. Bar , A. Shor , V. Dangendorf , G. Laczko , A. Breskin , R. Chechik

We report a new scenario of time-of-flight (TOF) technique in which fast neutrons and delayed gamma-ray signals were both recorded in a millisecond time window in harsh environments induced by high-intensity lasers. The delayed gamma…

The feasibility of performing fast neutron resonance radiography at the PTB accelerator facility is studied. A neutron beam of a broad spectral distribution is produced by a pulsed 13 MeV deuterium beam hitting a thick Be target. The…

核实验 · 物理学 2007-05-23 V. Dangendorf , G. Laczko , C. Kersten , O. Jagutzki , U. Spillmann

We have developed a photon counting detector system for combined neutron and gamma radiography which can determine position, time and intensity of a secondary photon flash created by a high-energy particle or photon within a scintillator…

The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study…

仪器与探测器 · 物理学 2015-06-04 M. Cortesi , R. Zboray , R. Adams , V. Dangendorf , H. -M. Prasser

Neutron imaging is one of the most powerful tools for nondestructive inspection owing to the unique characteristics of neutron beams, such as high permeability for many heavy metals, high sensitivity for certain light elements, and isotope…

The photoneutron source (PNS, phase 1), an electron linear accelerator (linac)-based pulsed neutron facility that uses the time-of-flight (TOF) technique, was constructed for the acquisition of nuclear data from the thorium molten salt…

Neutron imaging is one of the key technologies for non-destructive transmission testing. Recent progress in the development of intensive neutron sources allows us to perform energy-resolved neutron imaging with high spatial resolution.…

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe…

仪器与探测器 · 物理学 2017-10-04 I. Israelashvili , A. E. C. Coimbra , D. Vartsky , L. Arazi , S. Shchemelinin , E. N. Caspi , A. Breskin

3D time-of-flight (ToF) imaging is used in a variety of applications such as augmented reality (AR), computer interfaces, robotics and autonomous systems. Single-photon avalanche diodes (SPADs) are one of the enabling technologies providing…

图像与视频处理 · 电气工程与系统科学 2021-10-13 Germán Mora-Martín , Alex Turpin , Alice Ruget , Abderrahim Halimi , Robert Henderson , Jonathan Leach , Istvan Gyongy

The white neutron beamline at the China Spallation Neutron Source will be used mainly for nuclear data measurements. It will be characterized by high flux and broad energy spectra. To exploit the beamline as a neutron imaging source, we…

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

Coincidence and time-of-flight measurement techniques are employed to tag fission neutrons emitted from a 252Cf source sealed on one side with a very thin layer of Au. The source is positioned within a gaseous 4He scintillator detector.…

Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture…

‹ 上一页 1 2 3 10 下一页 ›