中文
相关论文

相关论文: Transport properties of electrons in CF4

200 篇论文

This paper presents a measurement of the ratio of photon to electron production and the scintillation spectrum in a popular gas for time pro jection chambers, carbon tetrafluoride (CF4), over the range of 200 to 800 nm; the ratio is…

Low pressure gaseous Time Projection Chambers (TPCs) are a viable technology for directional Dark Matter (DM) searches and have the potential for exploring the parameter space below the neutrino fog. Gases like CF4 are advantageous because…

仪器与探测器 · 物理学 2024-02-27 A. G. McLean , N. J. C. Spooner , T. Crane , C. Eldridge , A. C. Ezeribe , R. R. Marcelo Gregorio , A. Scarff

This report summarizes some useful data on the transport characteristics of gas mixtures which are required for detection of charged particles in gas detectors. We try to replace Freon used for RPC detector in the CMS experiment with…

仪器与探测器 · 物理学 2011-11-01 Yasser Assran , Archana Sharma

Argon with an admixture of CF4 is expected to be a good candidate for the gas mixture to be used for a time projection chamber (TPC) in the future linear collider experiment because of its small transverse diffusion of drift electrons…

The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF$_4$ based gas mixtures were used in two different…

Resistive Plate Chambers detectors are extensively used in several domains of Physics. In High Energy Physics, they are typically operated in avalanche mode with a high-performance gas mixture based on Tetrafluoroethane (C2H2F4), a…

仪器与探测器 · 物理学 2025-10-08 D. Ahmadi , M. Tytgat

The known direction of motion of dark matter particles relative to the Earth may be a key for their unambiguous identification even in the presence of backgrounds. We describe a prototype detector that is able to reconstruct direction…

SF$_{6}$ is an inert and electronegative gas that has a long history of use in high voltage insulation and numerous other industrial applications. Although SF$_{6}$ is used as a trace component to introduce stability in tracking chambers,…

仪器与探测器 · 物理学 2024-07-19 N. S. Phan , R. Lafler , R. J. Lauer , E. R. Lee , D. Loomba , J. A. J. Matthews , E. H. Miller

Images of resolved 5.9 keV electron tracks produced from $^{55}$Fe X-ray interactions are presented for the first time using an optical readout time projection chamber (TPC). The corresponding energy spectra are also shown, with the FWHM…

仪器与探测器 · 物理学 2024-07-19 N. S. Phan , E. R. Lee , D. Loomba

Scintillation detector is widely used for the particle detection in the field of particle physics. Particle detectors containing fluorine-19 ($^{19}\mathrm{F}$) are known to have advantages for Weakly Interacting Massive Particles (WIMPs)…

仪器与探测器 · 物理学 2022-01-03 Keita Mizukoshi , Takeshi Maeda , Yuuki Nakano , Satoshi Higashino , Kentaro Miuchi

The DMTPC detector is a low-pressure CF4 TPC with optical readout for directional detection of Dark Matter. The combination of the energy and directional tracking information allows for an efficient suppression of all backgrounds. The…

A comprehensive analysis of the effects of Geant4 algorithms for condensed transport in detectors is in progress. The first phase of the project focuses on electron multiple scattering, and studies two related observables: the longitudinal…

计算物理 · 物理学 2015-06-11 M. Batic , G. Hoff , M. G. Pia

We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture…

Radiation detection is vital for space, medical imaging, homeland security, and environmental monitoring applications. In the past, the Monte Carlo radiation transport toolkit, Geant4, has been employed to enable the effective development…

仪器与探测器 · 物理学 2024-10-14 Lysander Miller , Airlie Chapman , Katie Auchettl , Jeremy M. C. Brown

A gaseous time-projection chamber (TPC) with a reconstructable $z$ coordinate for nuclear recoil tracks has been developed for dark-matter searches and $\alpha$ particle imagings in a low radioactivity background. A TPC with a…

仪器与探测器 · 物理学 2022-02-21 Hiroshi Ito

A novel method to image charge is used to measure the diffusion coefficient of electrons in films of CdSe nanocrystals at room temperature. This method makes possible the study of charge transport in films exhibiting high resistances or…

介观与纳米尺度物理 · 物理学 2009-11-10 M. Drndic , R. Markov , M. V. Jarosz , M. G. Bawendi , M. A. Kastner , N. Markovic , M. Tinkham

A Negative Ion Time Projection Chamber was used to measure the field dependence of lateral and longitudinal diffusion for CS$_2$ anions drifting in mixtures of CS$_2$ and Ar at 40 Torr. Ion drift velocities and limits on the capture…

仪器与探测器 · 物理学 2009-11-06 Tohru Ohnuki , Daniel P. Snowden-Ifft , C. J. Martoff

In recent years, there has been growing interest in tetrafluoropropene HFO1234ze(E) (C$_{3}$H$_{2}$F$_{4}$) for Resistive Plate Chambers (RPCs). This novel gas is considered a promising alternative to the standard mixtures currently used in…

等离子体物理 · 物理学 2024-03-12 Antonio Bianchi , Alessandro Ferretti , Martino Gagliardi , Ermanno Vercellin

The DMTPC directional dark matter detection experiment is a low-pressure CF4 gas time projection chamber, instrumented with charge and scintillation photon readout. This detector design strategy emphasizes reconstruction of WIMP-induced…

仪器与探测器 · 物理学 2019-08-13 Jocelyn Monroe

Gaseous detectors are widely used in high-energy physics experiments, and in particular at the CERN Large Hadron Collider (LHC), to provide tracking and triggering over large volumes. It has been recently estimated that Resistive Plate…

‹ 上一页 1 2 3 10 下一页 ›