中文
相关论文

相关论文: Defocus test and defocus correction in full-field …

200 篇论文

High-resolution optical imaging methods, such as confocal microscopy and full-field optical coherence tomography, capture flat optical sections of the sample. If the sample is curved, the optical field sections through several sample layers…

Monocular depth estimation is an important step in many downstream tasks in machine vision. We address the topic of estimating monocular depth from defocus blur which can yield more accurate results than the semantic based depth estimation…

计算机视觉与模式识别 · 计算机科学 2023-11-23 Lahiru Wijayasingha , Homa Alemzadeh , John A. Stankovic

This short textbook was written for someone who newly start studying, doing research, or development about optical coherence tomography (OCT) or using OCT. The first chapter summarizes the concept and the history of OCT. In the second…

医学物理 · 物理学 2022-12-09 Yoshiaki Yasuno

Optical path length and dispersion matching in both measurement and reference arms of an OCT system is critical for achieving bandwidth-limited axial resolution. To minimize or eliminate dispersion mismatch, most, if not all, fiber-based…

光学 · 物理学 2025-10-06 Shau Poh Chong , Peter Török

This study is to characterize reflectance profiles of retinal blood vessels in optical coherence tomography (OCT), and to validate these vascular features to guide artery-vein classification in OCT angiography (OCTA) of human retina.…

组织与器官 · 定量生物学 2022-02-08 Tobiloba Adejumo , Tae-Hoon Kim , David Le , Taeyoon Son , Guangying Ma , Xincheng Yao

Optoacoustic tomography (OAT), also known as photoacoustic tomography, is a rapidly emerging hybrid imaging technique that possesses great potential for a wide range of biomedical imaging applications. In OAT, a laser is employed to…

医学物理 · 物理学 2016-12-21 Yang Lou , Kun Wang , Alexander. A. Oraevsky , Mark. A. Anastasio

Optical Coherence Tomography (OCT) is an emerging medical imaging modality for luminal organ diagnosis. The non-constant rotation speed of optical components in the OCT catheter tip causes rotational distortion in OCT volumetric scanning.…

Clinical tracking systems are popular but typically require specific tracking markers. During the last years, scanning speed of optical coherence tomography (OCT) has increased to A-scan rates above 1 MHz allowing to acquire volume scans of…

Image retargeting, which resizes images to one with a prescribed aspect ratio by determining an optimal warping map, has gained substantial interest in imaging science. Despite significant advances, existing methods often fail to ensure…

数值分析 · 数学 2025-10-16 Chengyang Liu , Michael K. Ng

Biophotonics is an active research area in molecular imaging, genetic diagnosis and prognosis, with direct applicability in precision medicine. However, long-standing challenges of biophotonics are well known due to low signal-to-noise…

医学物理 · 物理学 2017-10-02 Michael C Lun , Wei Zhang , Yue Zhao , Jeffrey Anker , Wenxiang Cong , Ge Wang , Changqing Li

Optical coherence tomography (OCT) is a medical imaging modality that allows us to probe deeper substructures of skin. The state-of-the-art wound care prediction and monitoring methods are based on visual evaluation and focus on surface…

图像与视频处理 · 电气工程与系统科学 2023-06-05 Prashant Kumar , Swatantra Dhara , Ayan Gope , Jyotirmoy Chatterjee , Subhamoy Mandal

We show that with spatially incoherent illumination, the point spread function width of an imaging interferometer like that used in full-field optical coherence tomography (FFOCT) is almost insensitive to aberrations that mostly induce a…

光学 · 物理学 2016-08-16 Peng Xiao , Mathias Fink , A. Claude Boccara

This paper presents a blind detection and compensation technique for camera lens geometric distortions. The lens distortion introduces higher-order correlations in the frequency domain and in turn it can be detected using higher-order…

计算机视觉与模式识别 · 计算机科学 2007-05-23 Lili Ma , YangQuan Chen , Kevin L. Moore

Optical coherence tomography (OCT) scanning is useful in detecting various retinal diseases. However, there are not enough ophthalmologists who can diagnose retinal OCT images in much of the world. To provide OCT screening inexpensively and…

计算机视觉与模式识别 · 计算机科学 2020-07-21 Ayaka Suzuki , Yoshiro Suzuki

Optical coherence tomography (OCT) suffers from speckle noise, causing the deterioration of image quality, especially in high-resolution modalities like visible light OCT (vis-OCT). The potential of conventional supervised deep learning…

图像与视频处理 · 电气工程与系统科学 2024-05-16 Lingyun Wang , Jose A Sahel , Shaohua Pi

Accurate quantification in positron emission tomography (PET) is essential for accurate diagnostic results and effective treatment tracking. A major issue encountered in PET imaging is attenuation. Attenuation refers to the diminution of…

We describe and experimentally validate an algorithm to reconstruct an unknown extended object from through-focus measured image intensities blurred by unknown aberrations. It is shown that the method can recover diffraction-limited image…

光学 · 物理学 2015-10-29 Yifeng Shao , Niek Doelman , Silvania F. Pereira , H. Paul Urbach

Since X-ray tomography is now widely adopted in many different areas, it becomes more crucial to find a robust routine of handling tomographic data to get quality reconstructed images. Though there are several existing techniques, it seems…

医学物理 · 物理学 2021-12-17 Kyungtaek Jun , Seokhwan Yoon , Kyu Kwon

Optical Coherence Tomography (OCT) imaging is pivotal in diagnosing ophthalmic conditions by providing detailed cross-sectional images of the anterior and posterior segments of the eye. Nonetheless, speckle noise and other imaging artifacts…

图像与视频处理 · 电气工程与系统科学 2024-09-26 Akkidas Noel Prakash , Jahnvi Sai Ganta , Ramaswami Krishnadas , Tin A. Tunc , Satish K Panda

Optical Coherence Tomography (OCT) image denoising is a fundamental problem as OCT images suffer from multiplicative speckle noise, resulting in poor visibility of retinal layers. The traditional denoising methods consider specific…

图像与视频处理 · 电气工程与系统科学 2022-09-21 Arka Saha , Sourya Sengupta