相关论文: IEEE 1149.4 Compatible ABMs for Basic RF Measureme…
Does gravity influence local measurements? We use a dual-species atom interferometer with $2\,\text{s}$ of free-fall time to measure the relative acceleration between $^{85}$Rb and $^{87}$Rb wave packets in the Earth's gravitational field.…
This paper presents a joint calibration scheme for voltage (V) and current (I) probes that helps resolve accurately voltage-current phase differences even when the difference is very close to $90^{\circ}$. The latter has been a major issue…
Ranging and localisation have become critical for many applications and services. The Wi-Fi (IEEE 802.11) standard is a natural candidate for providing these functions across diverse environments, given its widespread deployment. The IEEE…
The accuracy of Einstein's Equivalence Principle (EEP) can be tested with the observed time delays between correlated particles or photons that are emitted from astronomical sources. Assuming as a lower limit that the time delays are caused…
High-sensitive measurement of radio-frequency (RF) electric field is available via the electromagnetically induced transparency (EIT) effect of Rydberg atom at room-temperature, which has been developed to be a promising atomic RF receiver.…
This paper describes hardware and software improvements of the INRIM coaxial microcalorimeter together with their outcome on the primary power standard realization in the frequency band 0.05 - 40 GHz. A better temperature and power…
This paper presents an observing methodology for calibrated measurements of radio interference levels and compare these with threshold interference limits that have been established for interference entering the bands allocated to the Radio…
Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be less sensitive to absolute temperature and not downward…
This paper investigates the identification of observable low-frequency (LF) parameters of battery cell's equivalent circuit models (ECMs) using time-domain voltage and current measurements sampled at low frequency by built-in battery…
We report here the characterization (temperature coefficients and noise level) of selected voltage references in the frequency range from 10^(-5) to 10 Hz. The goal of this work is to update previous studies, with a characterization at…
We report on two-terminal-pair and four-terminal-pair test measurements of a 10-kohm resistance standard by means of a commercial precision LCR meter at frequencies up to 2 MHz. In the case of a two-terminal-pair configuration, we…
This paper proposes a scheme to measure atomic parity violation (APV) in barium ions at <0.1% precision. The scheme is based on using multi-ion entangled states to common-mode reject parity-conserving systematic shifts and selectively…
Customized voltage waveforms composed of a number of frequencies and used as the excitation of radio-frequency plasmas can control various plasma parameters such as energy distribution functions, homogeneity of the ionflux or ionization…
We theoretically study the quantum receivers with adaptive measurements feedback for discriminating quadrature amplitude modulation (QAM) coherent states in terms of average symbol error rate. For rectangular 16-QAM signal set, with…
The article deals with the development, implementation and research of the spectrum analyzers that can be used in sensor networks and Internet systems of things. As an operating frequency range, 2.4-2.5 GHz ISM is selected. At the stage of…
A new coded modulation scheme is proposed. At the transmitter, the concatenation of a distribution matcher and a systematic binary encoder performs probabilistic signal shaping and channel coding. At the receiver, the output of a bitwise…
The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial power sensors with indirect heating thermocouples. The…
8-Gsps 1-bit Analog-to-Digital Converters (ADCs) were newly developed toward the realization of the wideband observation. The development of the wideband ADCs is one of the most essential developments for the radio interferometer. To…
Very long baseline interferometry (VLBI) technique allows us to determine positions of thousands of radio sources using the absolute astrometry approach. I have investigated the impact of a selection of observing frequencies in a range from…
Radio map estimation (RME) is the problem of inferring the value of a certain metric (e.g. signal power) across an area of interest given a collection of measurements. While most works tackle this problem from a purely non-Bayesian…