相关论文: Luminosity determination at HERA-B
Two methods of the luminosity determination for the experiment performed by WASA collaboration to search for $^{4} {-0.03cm}{He}$-$\eta$ bound state are presented. During the measurement the technique of continous change of the beam…
The integrated luminosities of the data samples collected in the BESIII experiment in 2016--2017 at center-of-mass energies between 4.19 and 4.28 GeV are measured with a precision better than 1% by analyzing large-angle Bhabha scattering…
We establish an empirical effective temperature calibration of main sequence, luminosity class V to III B-type stars for the Delta a photometric system which was originally developed to detect magnetic chemically peculiar objects of the…
The mostly research fasten on high emission density of injector to study electron beam's brightness in LIA. Using the injector(2MeV) was built to research brightness of multi-pulsed high current(KA) electron beam, and researchs three…
After more than 15 years, the operation of the world's unique electron-proton collider HERA ended in June 2007. The data collected by the H1 experiment correspond to a total integrated luminosity of about 0.5 fb$^{-1}$. In 2007 dedicated…
A measurement of the longitudinal polarization of the electron beam at HERA utilizing coherent interactions of high energy photons in crystals is proposed. Modification of existing facilities would allow an independent polarization…
Luminosity is a measure of the colliding frequency between beam and target and it is a crucial parameter for the measurement of absolute values, such as reaction cross sections. In this paper, we make use of experimental data from the ESR…
Results are presented for a simulation carried out to test the precision with which a detector design (HERON) based on a superfluid helium target material should be able to measure the solar pp and Be7 fluxes. It is found that precisions of…
A Fabry-Perot cavity polarimeter, installed in 2003 at HERA for the second phase of its operation, is described. The cavity polarimeter was designed to measure the longitudinal polarisation of the HERA electron beam with high precision for…
A first measurement of the 1-jettiness event shape observable $\tau_1^b$ in neutral-current deep inelastic scattering is presented. For the measurement, the equivalence of $\tau_1^b$ to the DIS thrust observable defined in the Breit frame…
The high resolution of the LHCb vertex detector makes it possible to perform precise measurements of vertices of beam-gas and beam-beam interactions and allows beam parameters such as positions, angles and widths to be determined. Using the…
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the…
An assessment of the recorded integrated luminosity is presented for data collected with the D0 detector at the Fermilab Tevatron Collider from June 2006 to September 2011 (Run IIb). In addition, a measurement of the effective cross section…
In order to estimate in absolute terms the luminosity of LHC certain beam parameters have to be measured very accurately. In particular the total beam current and the relative distribution of the charges around the ring, the transverse size…
From December 2011 to May 2014, about 5 $\rm fb^{-1}$ of data were taken with the BESIII detector at center-of-mass energies between 3.810 GeV and 4.600 GeV to study the charmoniumlike states and higher excited charmonium states. The time…
A series of data samples was collected with the Belle~II detector at the SuperKEKB collider from March 2019 to June 2022. We determine the integrated luminosities of these data samples using three distinct methodologies involving Bhabha…
New QCD results obtained by the H1 Collaboration are summarized. These results are based on data taken in $e^{\pm}p$ collisions at HERA I (1994-2002) and HERA II (2003-2007) corresponding to an integrated luminosity of almost $\rm 0.5…
This is the first of the series of papers which present a precision method of the day-by-day monitoring of the absolute LHC luminosity. The method is based on the measurement of the rate of coplanar lepton pairs produced in peripheral…
More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven…
Using deep inelastic $e^{\pm}p$ charged and neutral current scattering cross sections previously published, a combined electroweak and QCD analysis is performed to determine electroweak parameters accounting for their correlation with…