本研究详细介绍了利用印刷和其他增材工艺制备一种新型安培型葡萄糖传感器的过程。该传感器以镀金 12.7 微米聚酰亚胺薄膜为起始材料,分别采用微接触印刷、电化学电镀和氯化、电流体动力学喷射(e-jet)印刷以及旋涂技术对功能材料进行图案化、沉积、印刷和涂覆。我们发现 e-jet 印刷可有效沉积和图案化宽度在~5 至 1000 微米之间的葡萄糖氧化酶墨水,并证实酶在印刷后仍保持活性。优化了 permselective 层的厚度,以获得高达 32 mM 葡萄糖浓度的线性响应。对于这些传感器,未观察到对常见干扰化合物对乙酰氨基酚的响应。