光电倍增管阵列的标定
仪器与探测器
2012-05-25 v1
摘要
描述了一种能够标定和评估光电倍增管阵列响应线性度的方法。该方法不需要知道光电倍增管单光电子响应模型,并直接使用科学数据,从而消除了对专用数据集的需求。通过这种方式,所有光电倍增管的工作条件(例如温度、外部场等)在标定和科学采集之间完全匹配。这对于诸如ZEPLIN-III等低本底实验尤为重要,在这些实验中,使用外部光源进行标定的方法受到严重限制。
引用
@article{arxiv.0905.2523,
title = {Calibration of Photomultiplier Arrays},
author = {F. Neves and V. Chepel and D. Yu. Akimov and H. M. Araujo and E. J. Barnes and V. A. Belov and A. A. Burenkov and A. Currie and B. Edwards and C. Ghag and M. Horn and A. J. Hughes and G. E. Kalmus and A. S. Kobyakin and A. G. Kovalenko and V. N. Lebedenko and A. Lindote and M. I. Lopes and R. Luscher and K. Lyons and P. Majewski and A. StJ. Murphy and J. Pinto da Cunha and R. Preece and J. J. Quenby and P. R. Scovell and C. Silva and V. N. Solovov and N. J. T. Smith and P. F. Smith and V. N. Stekhanov and T. J. Sumner and C. Thorne and R. J. Walker},
journal= {arXiv preprint arXiv:0905.2523},
year = {2012}
}
备注
15 pages, 6 figures