English
Related papers

Related papers: Characterising a Si(Li) detector element for the S…

200 papers

Silicon pixel detectors produced according to the ATLAS Pixel Detector design were tested in a beam at CERN in the framework of the ATLAS collaboration. The detectors used n+/n sensors with oxygenated silicon substrates. The experimental…

High Energy Physics - Experiment · Physics 2007-05-23 T. Lari

A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…

Instrumentation and Detectors · Physics 2014-11-24 T. J. Langford , C. D. Bass , E. J. Beise , H. Breuer , D. K. Erwin , C. R. Heimbach , J. S. Nico

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will…

shortened) Results obtained from 9 X-ray observations of 3C 273 performed by ASCA are presented (for a total exposure time of about 160 000 s). The analysis and interpretation of the results is complicated by the fact that 4 of these…

Astrophysics · Physics 2015-06-24 M. Cappi , M. Matsuoka , C. Otani , K. M. Leighly

This paper presents the results of a study of the response of a test CMOS sensor with a radiation tolerant pixel cell design to 80 keV and 100 keV electrons. The point spread function is measured to be (13.0+/- 1.7) microns at 100 keV and…

Instrumentation and Detectors · Physics 2009-06-25 Marco Battaglia , Devis Contarato , Peter Denes , Dionisio Doering , Velimir Radmilovic

From the spectral analysis of a broadband (0.1-200 keV) BeppoSAX observation of the Seyfert 1 galaxy IC 4329A, the main results obtained are: a) the amount of reflection, together with the intensity of the iron K line, indicate a geometry…

Astrophysics · Physics 2007-05-23 G. C. Perola

X-ray scattering spectra of Cu and Ni metals have been measured using monochromatic synchrotron radiation tuned from far above to more than 10 eV below threshold. Energy conservation in the scattering process is found to be sufficient to…

Materials Science · Physics 2012-01-04 M. Magnuson , J. -E. Rubensson , A. Föhlisch , N. Wassdahl , A. Nilsson , N. Mårtensson

Experimental results for the reflection coefficient of shock-compressed dense Xenon plasmas at pressures of 1.6 - 17 GPa and temperatures around 30 000 K using a laser beam with \lambda = 1.06 10^-6 m are compared with calculations based on…

Plasma Physics · Physics 2009-11-07 H. Reinholz , G. Roepke , A. Wierling , V. Mintsev , V. Gryaznov

We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…

We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of an all-silicon fabrication platform, in contrast to the more…

Hydrogenated amorphous silicon (a-Si:H) has remarkable radiation resistance properties and can be deposited on a lot of different substrates. A-Si:H based particle detectors have been built since mid 1980s as planar p-i-n or Schottky diode…

The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was…

We present a compact on-chip resonator enhanced silicon-MSM photodetector in $850$ $nm$ wavelength band for communication and lab-on-chip bio-sensing applications. We report the highest responsivity of 0.81 A/W for a 5 $\mu m$ long device.…

Applied Physics · Physics 2020-12-02 Avijit Chatterjee , Saumitra Sam , Sujit Kumar Sikdar , Shankar Kumar Selvaraja

The Strontium Iodide Radiation Instrument (SIRI) is a single detector, gamma-ray spectrometer designed to space-qualify the new scintillation detector material europium-doped strontium iodide (SrI2:Eu) and new silicon photomultiplier (SiPM)…

Instrumentation and Methods for Astrophysics · Physics 2019-07-29 Lee J. Mitchell , Bernard F. Phlips , J. Eric Grove , Theodore Finne , Mary Johnson-Rambert , W. Neil Johnson

Geant4 simulations play a crucial role in the analysis and interpretation of experiments providing low energy precision tests of the Standard Model. This paper focuses on the accuracy of the description of the electron processes in the…

Instrumentation and Detectors · Physics 2013-08-23 G. Soti , F. Wauters , M. Breitenfeldt , P. Finlay , I. S. Kraev , A. Knecht , T. Porobic , D. Zákoucký , N. Severijns

The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…

Instrumentation and Detectors · Physics 2007-05-23 S. V. Naydenov , V. D. Ryzhikov

Gamma radiation spectra of 1200 MeV electrons in the single crystals of the beryllium 1.2 mm thick, silicon 1.5 mm and 15.0 mm thick and tungsten 1.18 mm thick along of the crystallographic axes were measured. Also spectral-angular…

Accelerator Physics · Physics 2018-01-10 G. L. Bochek , O. S. Deiev , V. L. Kulibaba , N. I. Maslov , V. D. Ovchinnik , B. I. Schramenko

An aboveground 60-kg reactor-antineutrino detector prototype, comprised of a 2-dimensional array of 36 $^{6}$Li-doped pulse shape sensitive plastic scintillator bars, is described. Each bar is 50~cm long with a square cross section of…

The light output of the 324 CsI(Tl) scintillators of INDRA has been measured over a large range both in energy: 1 - 80 AMeV and in atomic number of incident ions: Z = 1 - 60. An analytical expression for the nonlinear total light response…