Related papers: Gas Purity effect on GEM Performance in He and Ne …
Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses…
Most attention to improving vacuum thermionic energy conversion device (TEC) technology has been on improving electron emission with little attention to collector optimization. A model was developed to characterize the output…
Background: we develop the concept of a Micromegas (MICRO-MEsh GAseous Structure) readout plane with an additional GEM (Gas Electron Multiplier) preamplification stage placed a few mm above it, to increase the maximum effective gain of the…
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…
The gas electron multiplier produced with the polyimide film 100 um thick. The maximum gas gain obtained with gas mixture Ar/CH4(91/9) was 5000. No decrease of gas gain with rates up to 2\cdot10^4 1/(mm^2 s) was observed. The possibility of…
Triple-GEM detectors for the GE2/1 and ME0 stations of the endcap muon system for the Phase-2 upgrade of the CMS Experiment have been operated in a test beam to measure their efficiency and spatial resolution, together with a high spatial…
The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to…
The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10{\mu}m) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double…
Gas electron Multipliers (GEM) are a new generation of gaseous avalanche devices in the Micro Patterned Gaseous Detector category. GEMs are widely used in both nuclear and high energy experiments as well as in medical science. Several…
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also…
Gas Electron Multipliers (GEM) are among the more prominent Micro-Pattern Gaseous Detectors (MPGDs) and widely used in high energy particle physics experiments and various related applications. Adoption of different production techniques…
A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…
A method is presented to derive electron temperatures and densities of planetary nebulae (PNe) simultaneously, using the observed hydrogen recombination spectrum, which includes continuum and line emission. By matching theoretical spectra…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between electrodes are created. The chambers containing MGEMs (WGEMs) with pin-anodes are proposed as detectors for…
The Gas Electron Multiplier (GEM) detectors has been utilized for various applications due to their excellent spatial resolution, high rate capabilities and flexibility in design. The GEM detectors stand as a promising device to be used in…
We measure transport through a Ga[Al]As heterostructure at temperatures between 0.1 K and 30 K. Increasing the temperature enhances the electron-electron scattering rate and viscous effects in the two-dimensional electron gas arise. To…
A systematic study is performed to measure the ion backflow fraction of the GEM detectors. The effects of different voltage configurations and Ar/CO_2 gas mixtures, in ratios of 70:30, 80:20 and 90:10, on positive ion fraction are…
Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas…
Thermoelectric power, electrical conductivity, and high field Hall effect were studied over a broad temperature range in ferromagnetic Ga(1-x)Mn(x)As epitaxial layers (0.015<x<0.06). Thermoelectric power analysis gives the information about…