Related papers: Gas Purity effect on GEM Performance in He and Ne …
We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…
The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level…
Experimental studies of electron mobilities in Neon as a function of the gas density have persistently shown mobilities up to an order of magnitude smaller than expected and predicted. A previously ignored mechanism (gas in--homogeneity…
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…
We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas…
Discrepancies between the measured and simulated gain in Thick Micropatterned gaseous detectors (MPGD), namely THGEM, have been observed by several groups. In order to simulate the electron avalanches and the gain the community relies on…
For its ease manufacturing, flexible geometry, and cheap manufacturing cost, the gas electron multiplier (GEM) detector can be used as an x-ray image sensor. For this purpose, we acquired relative detection efficiencies and suggested a…
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…
In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial…
Using optical pump-white light probe spectroscopy the gain dynamics is investigated for a VECSEL chip which is based on a type-II heterostructure. The active region the chip consists of a GaAs/(GaIn)As/Ga(AsSb)/(GaIn)As/GaAs multiple…
Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for…
The nuclear spins of low-density implanted Ga atoms in Ge are interesting candidates for solid state-based qubits. To date, activation studies of implanted Ga in Ge have focused on high densities. Here we extend activation studies into the…
W-value, mobility and gas gain measurements have been carried out in electronegative gaseous CS2 and CS2 gas mixtures at a pressure of 40 Torr making use of a single electron proportional counter method. The experimental results have…
The Gas Electron Multiplier (GEM) foil is an amplification stage that has been introduced to overcome the problem of discharges observed in gaseous detectors. There are two major production techniques of GEM foils: double-mask and…
The Gas Electron Multiplier detectors with wire and metallic electrodes, with a gas filling in the gap between them were proposed and tested. The main advantage of these Gas Electron Multipliers compared to standard ones consists in their…
In CBM Experiment at FAIR, dimuons will be detected by a Muon Chamber (MUCH) consisting of segmented absorbers of varying widths and tracking chambers sandwiched between the absorber-pairs. In this fixed target heavy-ion collision…
A novel instrument has been developed to monitor and record the ambient pa- rameters such as temperature, atmospheric pressure and relative humidity. These parameters are very essential for understanding the characteristics such as gain of…
The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…
Working gas components significantly impact the performance of gaseous detectors. A fast-timing Micromegas detector with two-stage amplification is prone to notable deterioration of uniformity when scaled up. This paper presents a…