English
Related papers

Related papers: Development and operation of a pixel segmented liq…

200 papers

We have developed a neutron imaging sensor based on an INTPIX4-SOI pixelated silicon device. Neutron irradiation tests are performed at several neutron facilities to investigate sensor's responses for neutrons. Detection efficiency is…

Instrumentation and Detectors · Physics 2020-08-04 Y. Kamiya , T. Miyoshi , H. Iwase , T. Inada , A. Mizushima , Y. Mita , K. Shimazoe , H. Tanaka , I. Kurachi , Y. Arai

We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors…

Instrumentation and Detectors · Physics 2020-03-18 U. Patel , R. Divan , L. Gades , T. Guruswamy , D. Yan , O. Quaranta , A. Miceli

We report on the calibration of an argon/isobutane (97.7 %/2.3 %)-filled GridPix detector with soft X-rays (277 eV to 8 keV) using the variable energy X-ray source of the CAST Detector Lab at CERN. We study the linearity and energy…

Instrumentation and Detectors · Physics 2018-04-18 Christoph Krieger , Jochen Kaminski , Theodoros Vafeiadis , Klaus Desch

The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability…

Resonant inelastic X-ray scattering (RIXS) has become an important scientific tool. Nonetheless, conventional high-resolution RIXS measurements (<100 meV), especially in the soft x-ray range, require large and low-throughput grating…

Materials Science · Physics 2020-06-22 Daniel J. Higley , Hirohito Ogasawara , Sioan Zohar , Georgi L. Dakovski

We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…

Instrumentation and Detectors · Physics 2022-01-27 Ángela Saá Hernández , Diego González-Díaz , Pablo Villanueva , Carlos Azevedo , Marcos Seoane

A new method of experimental verification of radial dose distribution models using solid state thermoluminescent (TL) detectors LiF:Mg,Cu,P has been recently proposed. In this work the method was applied to verify the spatial distribution…

Instrumentation and Detectors · Physics 2014-01-28 W. Gieszczyk , P. Bilski , P. Olko , B. Obryk

The calibration of the ICARUS photo-detection system is based on a low power laser diode at 405 nm. Laser pulses arrive to one optical switch and then are sent to 36 UHV flanges, by 20 meters long optical patches. Light is then delivered to…

Instrumentation and Detectors · Physics 2022-12-21 M. Bonesini , R. Benocci , R. Bertoni , A. Chatterjee , M. Diwan , A. Menegolli , G. Raselli , M. Rossella , A. Scarpelli , N. Suarez

Pixel sensors based on commercial high-voltage CMOS processes are an exciting technology that is considered as an option for the outer layer of the ATLAS inner tracker upgrade at the High Luminosity LHC. Here, charged particles are detected…

Carbon ion therapy have the ability to overcome the limitation of convertional radiotherapy due to its most energy deposition in selective depth, usually called Bragg peak, which results in increased biological effectiness. During carbon…

Integrated sensing and communications (ISAC) is emerging as a cornerstone technology for sixth generation (6G) wireless systems, unifying connectivity and environmental mapping through shared hardware, spectrum, and waveforms. The following…

Signal Processing · Electrical Eng. & Systems 2025-09-09 Ahmad Bazzi , Mingjun Ying , Ojas Kanhere , Theodore S. Rappaport , Marwa Chafii

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

The microhexcavity plasma panel detector is a type of gaseous particle detector consisting of a close-packed array of millimeter-size hexagonal cells. The cells are biased to operate in Geiger mode where each cell functions as an…

Monolithic CMOS pixel sensors offer unprecedented opportunities for fast nano-imaging through direct electron detection in transmission electron microscopy. We present the design and a full characterisation of a CMOS pixel test structure…

Using the Tunable Diode Laser Absorption Spectroscopy (TDLAS) 82 CH$_3$I ro-vibrational overtone absorption were detected for the first time between 11660 and 11840 cm$^{-1}$ (844 -- 857 nm), with strengths estimated to be around $10^{-27}$…

Chemical Physics · Physics 2023-04-14 Alessandro Lucchesini

A fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid…

Instrumentation and Detectors · Physics 2026-04-01 I-Chun Cho , Chien-Hsu Chen , Huan Niu , Cheng-Ya Pan , Chun-Hui Hsing , Tung-Yuan Hsiao

The existing ATLAS Tracker will be at its functional limit for particle fluences of 10^15 neq/cm^2 (LHC). Thus for the upgrades at smaller radii like in the case of the planned Insertable B-Layer (IBL) and for increased LHC luminosities…

Owing to their intrinsic (geometry dependent) radiation hardness, 3D pixel sensors are promising candidates for the innermost tracking layers of the forthcoming experiment upgrades at the Phase 2 High-Luminosity LHC (HL-LHC). To this…

Instrumentation and Detectors · Physics 2017-02-01 DMS Sultan , Gian-Franco Dalla Betta , Roberto Mendicino , Maurizio Boscardin , Sabina Ronchin , Nicola Zorzi

We report on the MIT Epoch of Reionization (MITEoR) experiment, a pathfinder low-frequency radio interferometer whose goal is to test technologies that improve the calibration precision and reduce the cost of the high-sensitivity 3D mapping…

We characterized the dosimetric properties of a clinical linear accelerator configured to deliver ultra-high dose rate (UHDR) irradiation to mice and cell-culture FLASH radiobiology experiments. UHDR electron beams were controlled by a…