Related papers: Optical Calibration For Jefferson Lab HKS Spectrom…
Context. Calibration of optical polarimeters relies on the use of stars with negligible polarization (unpolarized standard stars) for determining the instrumental polarization zero-point. For wide-field polarimeters, calibration is often…
Optical quantum computing, as well as quantum communication and sensing technology based on quantum correlations are in preparation. These require photodiodes for the detection of about 10^16 photons per second with close to perfect quantum…
We present a practical apparatus for characterizing optical aberrations of large collimation mirrors and lenses, and give a detailed analysis of wavefront-detection errors. We utilize a scanning pentaprism technique for precise measurements…
We present the development of a high-precision sample-position-autocorrection system for photoemission experiments. A binocular vision method based on image pattern matching calculations was realized to track the sample position with an…
The theoretical cross section for Compton scattering of maximally entangled Bell photons has yet to be rigorously confirmed by experiments. Test cases of Bell states for use in Compton scattering experiments can now be expanded given…
Reliable usage of object detectors require them to be calibrated -- a crucial problem that requires careful attention. Recent approaches towards this involve (1) designing new loss functions to obtain calibrated detectors by training them…
An acousto-optic cell was used to reduce the speckle noise that reduces the quality of Hartmann-Shack and other wave-front sensors measuring ocular aberrations. In the method presented here, a laser beam traverses an acousto-optic cell,…
A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing…
This paper presents a novel technique for camera calibration using a single view that incorporates a spherical mirror. Leveraging the distinct characteristics of the sphere's contour visible in the image and its reflections, we showcase the…
Quantitative inversion algorithms allow for the reconstruction of electrical properties (such as permittivity, and conductivity) for every point in a scene. However, they are challenging to use on measured datasets due to the need to know…
We have developed a calibration system based on a micro-electromechanical systems (MEMS) mirror that is capable of delivering an optical beam over a wavelength range of 180 -- 2000 nm (0.62 -- 6.89 eV) in a sub-Kelvin environment. This…
In the context of the Large Binocular Telescope project, we present the results of force actuator calibrations performed on an adaptive secondary prototype called P45, a thin deformable glass with magnets glued onto its back.…
Good geometrical calibration is essential in the use of high resolution detectors. The individual sensors in the detector have to be calibrated with an accuracy better than the intrinsic resolution, which typically is of the order of 10 um.…
In astronomy and microscopy, distortions in the wavefront affect the dynamic range of a high contrast imaging system. These aberrations are either imposed by a turbulent medium such as the atmosphere, by static or thermal aberrations in the…
Scattering scanning near-field optical microscopy enables optical imaging and characterization of plasmonic devices with nanometer-scale resolution well below the diffraction limit. This technique enables developers to probe and understand…
In a multi-sensor fusion system composed of cameras and LiDAR, precise extrinsic calibration contributes to the system's long-term stability and accurate perception of the environment. However, methods based on extracting and registering…
The paper proposes a novel calibration approach for the Orthoglide-type mechanisms based on observations of the manipulator leg parallelism during mo-tions between the prespecified test postures. It employs a low-cost measuring system…
Calibration errors in the response function of a gravitational wave detector degrade its ability to detect and then to measure the properties of any detected signals. This paper derives the needed levels of calibration accuracy for each of…
Adaptive finite elements are the method of choice for accurate simulations of optical components. However as shown recently by Bienstman et al. many finite element mode solvers fail to compute the propagation constant's imaginary part of a…
The loop induced coupling of an intermediate mass Higgs boson to two photons is a sensitive and unique measure for precision tests of physics beyond the Standard Model. In this work we summarize recent results on the expected precision of…