Related papers: Optical Calibration For Jefferson Lab HKS Spectrom…
Existing camera-projector calibration methods typically warp feature points from a camera image to a projector image using estimated homographies, and often suffer from errors in camera parameters and noise due to imperfect planarity of the…
A compensator (null-corrector) for testing aspheric optical surfaces is proposed, which enables i) independent verification of optical elements and assembling of the compensator itself, and ii) ascertaining the compensator position in a…
The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…
The value of accurately knowing the absolute calibration of the polarizing elements in the Near Infrared Camera and Multi-Object Spectrometer (NICMOS) becomes especially important when conducting studies which require measuring degrees of…
Cosmic Microwave Background (CMB) lensing is a powerful probe of the matter distribution in the Universe. The standard quadratic estimator, which is typically used to measure the lensing signal, is known to be suboptimal for low-noise…
We customized a laser calibration system and four radioactive $\gamma$-ray calibration sources for the Jiangmen Underground Neutrino Observatory (JUNO), a 20-kton liquid scintillator-based neutrino detector. The laser source system was…
Precision measurements of the polarization of the cosmic microwave background (CMB) radiation, especially experiments seeking to detect the odd-parity "B-modes", have far-reaching implications for cosmology. To detect the B-modes generated…
In this paper, we build an apparatus for measuring the optical transmittance and its uniformity for a semispherical surface at normal incidence; the system is primarily comprised of a traditional double-beam photometric framework and a…
Absolute normalisation of the LHC measurements with O(1%) precision and their relative normalisation, for the data collected at variable centre-of-mass energies, or for variable beam particle species, with O(0.1%) precision is crucial for…
A novel hand-eye calibration method for ground-observing mobile robots is proposed. While cameras on mobile robots are common, they are rarely used for ground-observing measurement tasks. Laser trackers are increasingly used in robotics for…
A calibration method aimed for the differential nonlinearity (DNL) error of the Low Energy X-ray Instrument (LE) onboard the Hard X-ray Modulation Telescope (HXMT) is presented, which is independent with electronic systems used as testing…
Adaptive optics systems require a calibration procedure to operate, whether in closed loop or even more importantly in forward control. This calibration usually takes the form of an interaction matrix and is a measure of the response on the…
We review the systematic uncertainties that have plagued attempts to obtain high precision and high accuracy from ground-based photometric measurements using CCDs. We identify two main challenges in breaking through the 1% precision…
The calibration of quantum measurements is limited by the ability to accurately prepare quantum states under unknown device errors. We develop an accurate calibration protocol for the measurement apparatus of a quantum computer that is…
We present a method to calibrate wavefront distortion of the spatial light modulator setup by registering far field images of several Gaussian beams diffracted off the modulator. The Fourier transform of resulting interference images…
Phase steps are an important type of wavefront aberrations generated by large telescopes with segmented mirrors. In a closed-loop correction cycle these phase steps have to be measured with the highest possible precision using natural…
This paper proposes a new approach for the calibration of material parameters in local elastoplastic constitutive models. The calibration is posed as a constrained optimization problem, where the constitutive model evolution equations for a…
Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce…
For the first time, a CAOS (i.e., Coded Access Optical Sensor) spectrometer is demonstrated. The design implemented uses a reflective diffraction grating and a time-frequency CAOS mode operations Digital Micromirror Device (DMD) in…
We present a design concept for a speckle based wavemeter that combines high spectral resolution and fast response times. Our device uses a fixed disperse medium with small coherence length as an optical pre-processor and a series of…