Related papers: Direct Observation of Broadband Coating Thermal No…
We derive accurate formulas for thermal fluctuations in multilayer interferometric coating taking into account light propagation inside the coating. In particular, we calculate the reflected wave phase as a function of small displacements…
We present an interferometric sensor for investigating macroscopic quantum mechanics on a table-top scale. The sensor consists of pair of suspended optical cavities with a finesse in excess of 100,000 comprising 10 g fused-silica mirrors.…
Mirror thermal noise is and will remain one of the main limitations to the sensitivity of gravitational wave detectors based on laser interferometers. We report about projected mirror thermal noise due to losses in the mirror coatings and…
The sensitivity of current and planned gravitational wave interferometric detectors is limited, in the most critical frequency region around 100 Hz, by a combination of quantum noise and thermal noise. The latter is dominated by Brownian…
This thesis presents a collection of different researches on non-standard optics in view of enhancing the performances of the Advanced Gravitational waves interferometric detectors, where the thermal noise of the test masses is expected to…
Uncertainties of refractive and group index in dispersion measurement by spectrally resolved white light interferometry are deeply analyzed. First, the contribution to uncertainty of the different parameters affecting both indices is…
Long duration noisy-looking waveforms such as those obtained in randomly multiply scattering and reverberant media are complex; they resist direct interpretation. Nevertheless, such waveforms are sensitive to small changes in the source of…
Direct observations of gravitational waves at frequencies below 10 Hz will play crucial roles for fully exploiting the potential of gravitational wave astronomy. One approach to pursue this direction is the utilization of laser…
We observe an interference pattern using a simple fiber-optic interferometer consisting of an electrical spectrum analyzer and a narrowband light source, which is commonly employed for observing the Brillouin gain spectrum. This…
Titania doped with tantala is the high index material (high n) for the optical coatings used in LIGO and Virgo and its thermal noise limits LIGO/Virgo observations of astrophysical sources. In this paper, we study temperature induced…
A folded resonant Fabry-Perot cavity has the potential to significantly reduce the impact of coating thermal noise on the performance of kilometer scale gravitational wave detectors. When constructed using only spherical mirror surfaces it…
Thermal lensing in resonant optical interferometers such as those used for gravitational wave detection is a concern due to the negative impact on control signals and instrument sensitivity. In this paper we describe a method for monitoring…
Amorphous tantala (a-Ta2O5) is an important technological material that has wide ranging applications in electronics, optics and the biomedical industry. It is used as the high refractive index layers in the multi-layer dielectric mirror…
Advanced LIGO's sensitivity will be limited by coating noise. Though this noise depends on beam shape, and though nongaussian beams are being seriously considered for advanced LIGO, no published analysis exists to compare the quantitative…
We have developed a new technique for photothermal displacement spectroscopy that is potentially orders of magnitude more sensitive than conventional methods. We use a single Fabry-Perot resonator to enhance both the intensity of the pump…
Annealing of amorphous optical coatings has been shown to generally reduce optical absorption, optical scattering, and mechanical loss, with higher temperature annealing giving better results. The achievable maximum temperatures are limited…
The sensitivity of kilometer-scale terrestrial gravitational wave interferometers is limited by mirror coating thermal noise. We explore the effect of folding the arm cavities of such interferometers. While simple folding alone does not…
We introduce a high performance differential dilatometer based on an all-fiber Michelson interferometer at cryogenic temperature with $10^{-10}$ resolution in $\delta L/L$. It resolve the linear thermal expansion coefficient by measuring…
We propose a simple way to improve the laser gravitational-wave detectors sensitivity by means of reduction of the number of reflective coating layers of the core optics mirrors. This effects in the proportional decrease of the coating…
Using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have measured the absolute refractive index of five specimens taken from a very large boule of Corning 7980 fused silica from…